• Availability & Price
  • Search SKU
Filter by attributes
  • Accuracy
  • Calibration Type
  • Division
  • Division
  • Flow Rates
  • For Fluid Type
  • Height
  • Length
  • Maximum Fluid Temperature
  • Minimum Fluid Temperature
More Filters...

SCVF volume counter

Picture for category SCVF volume counter

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Gear counter for highly accurate flow rate measurements in hydraulic systems

Function
The SCVF geared counter functions as a volume flow meter. A very precisely crafted pair of geared wheels is driven by the fluid flow. The SCVF works over a wide viscosity range. Different seals permit usage in many different applications.

Unique product features:
• Measurement principle: Volume/geared counter
• Eight measurement ranges from 0.01 - 2 to 1 - 300 l/min
• Accuracy ± 0.5 % FS
• Withstands pressures up to 400 bar (5802 psi)
• High viscosity range
• Low noise
• Exact flow rate measurement over a wide viscosity range
• Versatile usage for different substances

Markets:
• Industrial

Applications:
Due to the wide viscosity range, any liquid can be meas¬ured that can be pumped and has a certain degree of lubricating capability.
• Brake fluid (EPDM seal)
• Skydrol
• Mineral oils
• Hydraulic oil and
• Grease

The SCVF is the ideal solution when carrying out precise flow rate measurements over a wide viscosity range.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceMaximum Fluid TemperatureHeightAccuracyProduct StyleSpecifications MetOperating TemperatureWidthDivisionLengthWeightMinimum Fluid TemperatureFor Fluid TypeDivisionFlow RatesOperating PressureCalibration TypePort TypePort Size
K-SCVF-002-10-07
Backordered
POR
120 °C (148°F)n.a.± 0.5 % FSFlow MeterCE0...+55 °C / (32...131°F)n.a.High Pressure Connectors Europe Divisionn.a.n.a.-30 °C (-22 °F)Any liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.01...2.0 l/min400 bar / 5802 psiFactory calibration according to ISO 9001BSPPG3/8 BSPP
K-SCVF-004-10-07
Backordered
POR
120 °C (148°F)n.a.± 0.5 % FSFlow MeterCE0...+55 °C / (32...131°F)n.a.High Pressure Connectors Europe Divisionn.a.n.a.-30 °C (-22 °F)Any liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.02...4.0 l/min315 bar / 4569 psiFactory calibration according to ISO 9001BSPPG3/8 BSPP
K-SCVF-015-00-02
Backordered
POR
120 °Cn.a.± 0.5 % FSFlow MeterCE-15…+80 °Cn.a.High Pressure Connectors Europe Divisionn.a.n.a.-15 °CAny liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.2…15 l/min400 barFactory calibration according to ISO 9001BSPPG3/8 BSPP
K-SCVF-015-10-07
Backordered
POR
120 °C (148°F)n.a.± 0.5 % FSFlow MeterCE0...+55 °C / (32...131°F)n.a.High Pressure Connectors Europe Divisionn.a.n.a.-30 °C (-22 °F)Any liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.2...15 l/min400 bar / 5802 psiFactory calibration according to ISO 9001BSPPG3/8 BSPP
K-SCVF-040-10-07
Backordered
POR
120 °C (148°F)n.a.± 0.5 % FSFlow MeterCE0...+55 °C / (32...131°F)n.a.High Pressure Connectors Europe Divisionn.a.n.a.-30 °C (-22 °F)Any liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.4...40 l/min400 bar / 5802 psiFactory calibration according to ISO 9001BSPPG1/2 BSPP
K-SCVF-060-00-02
Backordered
POR
120 °Cn.a.± 0.5 % FSFlow MeterCE-15…+80 °Cn.a.High Pressure Connectors Europe Divisionn.a.n.a.-15 °CAny liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.4...60 l/min400 barFactory calibration according to ISO 9001BSPPG1/2 BSPP
K-SCVF-060-10-07
Backordered
POR
120 °C (148°F)n.a.± 0.5 % FSFlow MeterCE0...+55 °C / (32...131°F)n.a.High Pressure Connectors Europe Divisionn.a.n.a.-30 °C (-22 °F)Any liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.4...60 l/min400 bar / 5802 psiFactory calibration according to ISO 9001BSPPG1/2 BSPP
K-SCVF-150-00-02
Backordered
POR
120 °Cn.a.± 0.5 % FSFlow MeterCE-15…+80 °Cn.a.High Pressure Connectors Europe Divisionn.a.n.a.-15 °CAny liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.6...150 l/min315 barFactory calibration according to ISO 9001BSPPG1 BSPP
K-SCVF-150-10-07
Backordered
POR
120 °C (148°F)n.a.± 0.5 % FSFlow MeterCE0...+55 °C / (32...131°F)n.a.High Pressure Connectors Europe Divisionn.a.n.a.-30 °C (-22 °F)Any liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.6...150 l/min315 bar / 4569 psiFactory calibration according to ISO 9001BSPPG1 BSPP
K-SCVF-300-10-07
Backordered
POR
120 °C (148°F)n.a.± 0.5 % FSFlow MeterCE0...+55 °C / (32...131°F)n.a.High Pressure Connectors Europe Divisionn.a.n.a.-30 °C (-22 °F)Any liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division1.0...300 l/min315 bar / 4569 psiFactory calibration according to ISO 9001BSPPG1 BSPP
SCVF-002-10-07
Backordered
POR
120 °C (148°F)n.a.± 0.5 % FSFlow MeterCE0...+55 °C / (32...131°F)n.a.High Pressure Connectors Europe Divisionn.a.n.a.-30 °C (-22 °F)Any liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.01...2.0 l/min400 bar / 5802 psiNoneBSPPG3/8 BSPP
SCVF-004-10-07
Backordered
POR
120 °C (148°F)n.a.± 0.5 % FSFlow MeterCE0...+55 °C / (32...131°F)n.a.High Pressure Connectors Europe Divisionn.a.n.a.-30 °C (-22 °F)Any liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.02...4.0 l/min315 bar / 4569 psiNoneBSPPG3/8 BSPP
SCVF-015-00-02
Backordered
POR
120 °Cn.a.± 0.5 % FSFlow MeterCE-15…+80 °Cn.a.High Pressure Connectors Europe Divisionn.a.n.a.-15 °CAny liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.2…15 l/min400 barNoneBSPPG3/8 BSPP
SCVF-015-10-07
Backordered
POR
120 °C (148°F)n.a.± 0.5 % FSFlow MeterCE0...+55 °C / (32...131°F)n.a.High Pressure Connectors Europe Divisionn.a.n.a.-30 °C (-22 °F)Any liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.2...15 l/min400 bar / 5802 psiNoneBSPPG3/8 BSPP
SCVF-040-10-07
Backordered
POR
120 °C (148°F)n.a.± 0.5 % FSFlow MeterCE0...+55 °C / (32...131°F)n.a.High Pressure Connectors Europe Divisionn.a.n.a.-30 °C (-22 °F)Any liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.4...40 l/min400 bar / 5802 psiNoneBSPPG1/2 BSPP
SCVF-060-00-02
Backordered
POR
120 °Cn.a.± 0.5 % FSFlow MeterCE-15…+80 °Cn.a.High Pressure Connectors Europe Divisionn.a.n.a.-15 °CAny liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.4...60 l/min400 barNoneBSPPG1/2 BSPP
SCVF-060-10-07
Backordered
POR
120 °C (148°F)n.a.± 0.5 % FSFlow MeterCE0...+55 °C / (32...131°F)n.a.High Pressure Connectors Europe Divisionn.a.n.a.-30 °C (-22 °F)Any liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.4...60 l/min400 bar / 5802 psiNoneBSPPG1/2 BSPP
SCVF-080-10-07
Backordered
POR
120 °C (148°F)n.a.± 0.5 % FSFlow MeterCE0...+55 °C / (32...131°F)n.a.High Pressure Connectors Europe Divisionn.a.n.a.-30 °C (-22 °F)Any liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.4...80 l/min400 bar / 5802 psiNoneBSPPG1/2 BSPP
SCVF-150-00-02
Backordered
POR
120 °Cn.a.± 0.5 % FSFlow MeterCE-15…+80 °Cn.a.High Pressure Connectors Europe Divisionn.a.n.a.-15 °CAny liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.6...150 l/min315 barNoneBSPPG1 BSPP
SCVF-150-10-07
Backordered
POR
120 °C (148°F)n.a.± 0.5 % FSFlow MeterCE0...+55 °C / (32...131°F)n.a.High Pressure Connectors Europe Divisionn.a.n.a.-30 °C (-22 °F)Any liquid can be measured that can be pumped and has a certain degree of lubricating capability.High Pressure Connectors Europe Division0.6...150 l/min315 bar / 4569 psiNoneBSPPG1 BSPP

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains