Parker's highly precise mass flow controllers provide you the diagnostic stability and repeatability you need for low flow gas applications. Controlling thermal mass flow rates from 0.6 l/m to 1,670 l/m with high precision and <0.2% repeatability.  Rated for 8 separate gas types which are customer field adjustable. Our thermal mass flow controller is available in both digital and analog styles, fully compatible with RS232 and digital protocols such as Profibus.  If you're not sure what gas you're going to use or your process changes, our MFC allows you to migrate to a new gas within your flow range without purchasing a new mass flow controller.

Markets:
• Laboratory and Process Instrumentation
• Pharma/Bio-Pharma Equipment
• Air Quality Monitoring System
• Furnace and Coatings

Features/Benefits:
• Fast, Repeatable and Reliable Performance
• Premium Accuracy with Proven Thermal Mass Flow Sensor and Laminar Flow Element
• Easy to integrate into your new or existing systems
• Asset calibration management software included
• Cleaned for analytical use
• Fails shut with Normally Closed Valve for safe operation
• CE, REACH and RoHS II

Applications:
• Gas Control for Laboratory and Process Equipment
• Burner Ratio Control for Ceramics and Metals
• Process and Environmental Analyzers
• Emissions Monitors and Calibrators

Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceDivisionMaximum Operating TemperatureMinimum Operating TemperatureBody MaterialSpecifications MetLeak RateRepeatabilityTurndown RatioWetted MaterialFlow Rate AccuracyElectrical ConnectionTemperature CoefficientSeal MaterialValve TypeWarm-Up TimeSettling TimeSurface FinishConnection SizeConnection TypeControl StabilityPower ConsumptionConnection MaterialAttitude SensitivityPower Supply VoltagePressure CoefficientPressure Control RangeCommunication InterfaceFlow Rate
601CVMQAD88V
Backordered
POR
Precision Fluidics Division70 &#176;C-10 &#176;C316L Stainless SteelIP40Tested &lt; 2 x 10-9 mbar l/s He L/sec&lt; 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: &#177; 0.5% Reading plus &#177; 0.1% Full Scale (&#177; 1% Full Scale for ranges 3 - 5 ml/min; &#177; 2% Full Scale for ranges &lt; 3 ml/min)9-PIN D-CONNECTORZero: &lt; 0.05% Full Scale / &#176;C; span: &lt; 0.05% Reading / &#176;C &#176;CViton (Standard)Normally Open30 min. for optimum accuracy 2 min. for accuracy &#177;2% Full ScaleStandard: 2 - 4 seconds0.8 &#181;m typical1/4&quot;Face Seal Male&lt; &#177;0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90&#176; off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2 ATM928 PSIARS232 + Profibus - DP 0 to 5 Vdc4 - 15 L/min
601CVNAAD00V
Backordered
POR
Precision Fluidics Division70 &#176;C-10 &#176;C316L Stainless SteelIP40Tested &lt; 2 x 10-9 mbar l/s He L/sec&lt; 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: &#177; 0.5% Reading plus &#177; 0.1% Full Scale (&#177; 1% Full Scale for ranges 3 - 5 ml/min; &#177; 2% Full Scale for ranges &lt; 3 ml/min)9-PIN D-CONNECTORZero: &lt; 0.05% Full Scale / &#176;C; span: &lt; 0.05% Reading / &#176;C &#176;CViton (Standard)Normally Closed30 min. for optimum accuracy 2 min. for accuracy &#177;2% Full ScaleStandard: 2 - 4 seconds0.8 &#181;m typicalNoneNone&lt; &#177;0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90&#176; off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2 ATM928 PSIARS232 + Analog 0 to 5 Vdc8 - 25 L/min
601CVNAAD22V
Backordered
POR
Precision Fluidics Division70 &#176;C-10 &#176;C316L Stainless SteelIP40Tested &lt; 2 x 10-9 mbar l/s He L/sec&lt; 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: &#177; 0.5% Reading plus &#177; 0.1% Full Scale (&#177; 1% Full Scale for ranges 3 - 5 ml/min; &#177; 2% Full Scale for ranges &lt; 3 ml/min)9-PIN D-CONNECTORZero: &lt; 0.05% Full Scale / &#176;C; span: &lt; 0.05% Reading / &#176;C &#176;CViton (Standard)Normally Closed30 min. for optimum accuracy 2 min. for accuracy &#177;2% Full ScaleStandard: 2 - 4 seconds0.8 &#181;m typical1/4&quot;Compression&lt; &#177;0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90&#176; off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2 ATM928 PSIARS232 + Analog 0 to 5 Vdc8 - 25 L/min
601CVNAAD88V
Backordered
POR
Precision Fluidics Division70 &#176;C-10 &#176;C316L Stainless SteelIP40Tested &lt; 2 x 10-9 mbar l/s He L/sec&lt; 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: &#177; 0.5% Reading plus &#177; 0.1% Full Scale (&#177; 1% Full Scale for ranges 3 - 5 ml/min; &#177; 2% Full Scale for ranges &lt; 3 ml/min)9-PIN D-CONNECTORZero: &lt; 0.05% Full Scale / &#176;C; span: &lt; 0.05% Reading / &#176;C &#176;CViton (Standard)Normally Closed30 min. for optimum accuracy 2 min. for accuracy &#177;2% Full ScaleStandard: 2 - 4 seconds0.8 &#181;m typical1/4&quot;Face Seal Male&lt; &#177;0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90&#176; off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2 ATM928 PSIARS232 + Analog 0 to 5 Vdc8 - 25 L/min
601CVNAGD00V
Backordered
POR
Precision Fluidics Division70 &#176;C-10 &#176;C316L Stainless SteelIP40Tested &lt; 2 x 10-9 mbar l/s He L/sec&lt; 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: &#177; 0.5% Reading plus &#177; 0.1% Full Scale (&#177; 1% Full Scale for ranges 3 - 5 ml/min; &#177; 2% Full Scale for ranges &lt; 3 ml/min)9-PIN D-CONNECTORZero: &lt; 0.05% Full Scale / &#176;C; span: &lt; 0.05% Reading / &#176;C &#176;CViton (Standard)Normally Closed30 min. for optimum accuracy 2 min. for accuracy &#177;2% Full ScaleStandard: 2 - 4 seconds0.8 &#181;m typicalNoneNone&lt; &#177;0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90&#176; off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2 ATM928 PSIARS232 + Analog 4 to 20 mA Sourcing8 - 25 L/min
601CVNAGD22V
Backordered
POR
Precision Fluidics Division70 &#176;C-10 &#176;C316L Stainless SteelIP40Tested &lt; 2 x 10-9 mbar l/s He L/sec&lt; 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: &#177; 0.5% Reading plus &#177; 0.1% Full Scale (&#177; 1% Full Scale for ranges 3 - 5 ml/min; &#177; 2% Full Scale for ranges &lt; 3 ml/min)9-PIN D-CONNECTORZero: &lt; 0.05% Full Scale / &#176;C; span: &lt; 0.05% Reading / &#176;C &#176;CViton (Standard)Normally Closed30 min. for optimum accuracy 2 min. for accuracy &#177;2% Full ScaleStandard: 2 - 4 seconds0.8 &#181;m typical1/4&quot;Compression&lt; &#177;0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90&#176; off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2 ATM928 PSIARS232 + Analog 4 to 20 mA Sourcing8 - 25 L/min
601CVNBAD88V
Backordered
POR
Precision Fluidics Division70 &#176;C-10 &#176;C316L Stainless SteelIP40Tested &lt; 2 x 10-9 mbar l/s He L/sec&lt; 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: &#177; 0.5% Reading plus &#177; 0.1% Full Scale (&#177; 1% Full Scale for ranges 3 - 5 ml/min; &#177; 2% Full Scale for ranges &lt; 3 ml/min)9-PIN D-CONNECTORZero: &lt; 0.05% Full Scale / &#176;C; span: &lt; 0.05% Reading / &#176;C &#176;CViton (Standard)Normally Open30 min. for optimum accuracy 2 min. for accuracy &#177;2% Full ScaleStandard: 2 - 4 seconds0.8 &#181;m typical1/4&quot;Face Seal Male&lt; &#177;0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90&#176; off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2 ATM928 PSIARS232 + Analog 0 to 5 Vdc8 - 25 L/min