Tanktop Mounted Return Line Filter - TTF Series

Picture for category Tanktop Mounted Return Line Filter - TTF Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker TTF tank top mounted return line filters feature pre-filtration by means of a magnet column and a quick response bypass with low hysteresis. Thanks to the “In-to-Out” filter principle, contaminated oil cannot leak back into the system during element change.

TTF filters are available in formats capable of handling flow rates up to 500 l/min. They can operate up to a maximum working pressure of 10 bar. Options include a filling port in the filter cover, a second return port and customised diffusers can be specified.

Features and Benefits

• 10 bar rated filter can be utilised for severe return line applications for reduced downtime due to premature filter failures

• Patented LEIF® elements safeguard filtration quality

• Magnetic pre-filtration removes ferrous particles, even during bypass conditions for improved cleanliness levels and extended element life time

• In-to-out filtration means captured contamination is retained inside the element preventing recontamination of the filter

• Quick response bypass with low hysteresis for improved system protection.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceBrandTechnologyIndustryApplicationDivisionDivisionFilter Element TypeOperating TemperatureProduct SeriesMounting TypeIndicator Pressure SettingOperating PressureBypass Valve Pressure RatingProduct TypeProduct StyleSeal MaterialIndicator TypeMicron RatingFilter Element TypeConnection TypeOptionsBypass Valve Pressure RatingFlow RateFilter ElementBypass Valve (bar)Flow Capacity (l/min)Port Connection Type
TTF410QBPEG169
Backordered
POR
PARKERFiltrationConstructionPower PacksHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA10Q Microglass-40 to 100 °CTTF SeriesTanktop MountedNo indicator150 psi1.5 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileNo indicator, port plugged10 µm10Q MicroglassG1Funnel with hose connection1.5 bar0 to 170 l/min
TTF410QLBG1EG164
Backordered
POR
PARKERHydraulicsMaterials HandlingWheel LoadersHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA10QL Ecoglass-40 to 100 °CTTF SeriesTanktop Mounted1.2 bar150 psi1.5 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileVisual M10x110 µm10QL EcoglassG1Diffuser type P1.5 bar0 to 170 l/min10QL Ecoglass *1,5 *120G1 *
TTF410QLBP2E2G163
Backordered
POR
PARKERHydraulicsConstructionRefuse TrucksHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA10QL Ecoglass-40 to 100 °CTTF SeriesTanktop MountedNo indicator150 psi1.5 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileNo indicator, port plugged L+R10 µm10QL Ecoglass2 x G1Diffuser type T1.5 bar0 to 170 l/min
TTF410QLBP2EG163
Backordered
POR
PARKERHydraulicsMaterials HandlingDrilling EquipmentHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA10QL Ecoglass-40 to 100 °CTTF SeriesTanktop MountedNo indicator150 psi1.5 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileNo indicator, port plugged L+R10 µm10QL EcoglassG1Diffuser type T1.5 bar0 to 170 l/min10QL Ecoglass *1,5 *120G1 *
TTF410QLBP2HG161
Backordered
POR
PARKERHydraulicsTrucks and BusesPower PacksHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA10QL Ecoglass-40 to 100 °CTTF SeriesTanktop MountedNo indicator150 psi2 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileNo indicator, port plugged L+R10 µm10QL EcoglassG1No diffuser2.0 bar0 to 170 l/min
TTF410QLBS1EG163
Backordered
POR
PARKERFiltrationMaterials HandlingRefuse TrucksHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA10QL Ecoglass-40 to 100 °CTTF SeriesTanktop Mounted1.2 bar150 psi1.5 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileElectrical 42V, NO/NC, M10x110 µm10QL EcoglassG1Diffuser type T1.5 bar0 to 170 l/min10QL Ecoglass *1,5 *120G1 *
TTF420QBG1EG123
Backordered
POR
PARKERHydraulicsConstructionPower PacksHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA20Q Microglass-40 to 100 °CTTF SeriesTanktop Mounted1.2 bar150 psi1.5 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileVisual M10x120 µm20Q MicroglassG3/4Diffuser type T1.5 bar0 to 180 l/min20Q Microglass *1,5 *120G3/4 *
TTF420QBP2EG169
Backordered
POR
PARKERFiltrationMaterials HandlingDrilling EquipmentHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA20Q Microglass-40 to 100 °CTTF SeriesTanktop MountedNo indicator10 bar1.5 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileNo indicator, port plugged L+R20 µm20Q MicroglassG1Funnel with hose connection1.5 bar0 to 180 l/min
TTF420QBP2HG165
Backordered
POR
PARKERFiltrationTrucks and BusesPower PacksHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA20Q Microglass-40 to 100 °CTTF SeriesTanktop MountedNo indicator10 bar2 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileNo indicator, port plugged L+R20 µm20Q MicroglassG1No Diffuser, No Magnets2.0 bar0 to 180 l/min
TTF420QLBP2EG163
Backordered
POR
PARKERFiltrationTrucks and BusesWheel LoadersHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA20QL Ecoglass-40 to 100 °CTTF SeriesTanktop MountedNo indicator10 bar1.5 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileNo indicator, port plugged L+R20 µm20QL EcoglassG1Diffuser type T1.5 bar0 to 180 l/min20QL Ecoglass *1,5 *120G1 *
TTF4A10QBP2E2G164
Backordered
POR
PARKERHydraulicsMaterials HandlingDrilling EquipmentHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA10Q Microglass-40 to 100 °CTTF SeriesTanktop MountedNo indicator150 psi1.5 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileNo indicator, port plugged L+R10 µm10Q Microglass2 x G1Diffuser type P1.5 bar0 to 175 l/min
TTF4A10QBP2EG164
Backordered
POR
PARKERHydraulicsTrucks and BusesPower PacksHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA10Q Microglass-40 to 100 °CTTF SeriesTanktop MountedNo indicator150 psi1.5 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileNo indicator, port plugged L+R10 µm10Q MicroglassG1Diffuser type P1.5 bar0 to 175 l/min
TTF4A20QBP2EG164
Backordered
POR
PARKERHydraulicsTrucks and BusesPower PacksHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA20Q Microglass-40 to 100 °CTTF SeriesTanktop MountedNo indicator10 bar1.5 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileNo indicator, port plugged L+R20 µm20Q MicroglassG1Diffuser type P1.5 bar0 to 200 l/min
TTF4B10QBP2E2G164
Backordered
POR
PARKERHydraulicsConstructionMobile CranesHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA10Q Microglass-40 to 100 °CTTF SeriesTanktop MountedNo indicator10 bar1.5 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileNo indicator, port plugged L+R10 µm10Q Microglass2 x G1Diffuser type P1.5 bar0 to 200 l/min
TTF4B10QLBG6H2G16B
Backordered
POR
PARKERHydraulicsTrucks and BusesWheel LoadersHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA10QL Ecoglass-40 to 100 °CTTF SeriesTanktop Mounted0.8 bar10 bar2 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileVisual G1/810 µm10QL Ecoglass2 x G1Diffuser type P, No magnets2.0 bar0 to 200 l/min
TTF4B20QLBP2HG161
Backordered
POR
PARKERHydraulicsMaterials HandlingMobile CranesHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA20QL Ecoglass-40 to 100 °CTTF SeriesTanktop MountedNo indicator10 bar2 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileNo indicator, port plugged L+R20 µm20QL EcoglassG1No diffuser2.0 bar0 to 210 l/min
TTF502QLBP2HG16E
Backordered
POR
PARKERHydraulicsTrucks and BusesWheel LoadersHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA02QL Ecoglass-40 to 100 °CTTF SeriesTanktop MountedNo indicator10 bar2 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileNo indicator, port plugged L+R2 µm02QL EcoglassG12.0 bar0 to 75 l/min
TTF502QLBS1EG163
Backordered
POR
PARKERFiltrationConstructionMobile CranesHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA02QL Ecoglass-40 to 100 °CTTF SeriesTanktop Mounted1.2 bar150 psi1.5 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileElectrical 42V, NO/NC, M10x12 µm02QL EcoglassG1Diffuser type T1.5 bar0 to 75 l/min02QL Ecoglass1,5 *150 *G1 *
TTF505QBS1EG163
Backordered
POR
PARKERHydraulicsConstructionPower PacksHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA05Q Microglass-40 to 100 °CTTF SeriesTanktop Mounted1.2 bar10 bar1.5 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileElectrical 42V, NO/NC, M10x15 µm05Q MicroglassG1Diffuser type T1.5 bar0 to 175 l/min05Q Microglass1,5 *150 *G1 *
TTF505QLBG1EG123
Backordered
POR
PARKERFiltrationConstructionMobile CranesHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA05QL Ecoglass-40 to 100 °CTTF SeriesTanktop Mounted1.2 bar10 bar1.5 barHydraulic Oil FiltersTanktop Mounted Return Line FilterNitrileVisual M10x15 µm05QL EcoglassG3/4Diffuser type T1.5 bar0 to 175 l/min05QL Ecoglass *1,5 *150 *G3/4 *

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains