Flow measurement with low flow resistance. Combined p, T and Q measurement possible with additional sensors.

Function

A turbine wheel is driven by the oil flow. The frequencies thus produced are processed by digital electronics. The influence of turbulent flow effects is compensated for. Because of the low flow resistance QR the hydraulic circuit operates with very low losses. For pressure measurement, the turbine is equipped with an EMA-3 quick-connector. Oil temperatures can be measured directly in the oil flow in the turbine flow meter. Consequently all the important measurement parameters are available at one measuring location.

Features / Advantages:
• 6 measuring ranges of up to 750 l/min
• Easy installation
• High-pressure resistant up to 480 bar
• Low flow resistance
• Built-in pressure and temperature measurement connections
• Suitable for reverse-mode operation

Markets:
• Mobile and industrial hydraulics

Applications:
• Mobile diagnostic
• p-Q measurement
• Hydraulic tests with load valve
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceHeightProduct TypeAccuracyMaximum Fluid TemperatureWidthLengthSpecifications MetFor Fluid TypeWeightDivisionMinimum Fluid TemperatureDivisionOperating TemperatureCalibration TypeFlow RatesPort SizePort TypeProduct StyleOperating Pressure
K-SCFT-015-02-02
Backordered
POR
108 mmFlow meter analogue± 1 % FS90 °C37136 mmCEOil based hydraulic fluids650High Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CFactory calibration according to ISO 90011…015 l/min1/2“ BSPPBSPPAnalogoue Turbine350 bar
K-SCFT-015-22-07
Backordered
POR
115 mmFlow meter± 1 % FS80 °C37136CEOil based hydraulic fluids700 gHigh Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CFactory calibration according to ISO 90011...15 l/minG1/2 BSPPBSPPTurbine350 bar
K-SCFT-060-02-02
Backordered
POR
121 mmFlow meter analogue± 1 % IR90 °C62190 mmCEOil based hydraulic fluids750High Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CFactory calibration according to ISO 90013…060 l/min3/4“ BSPPBSPPAnalogoue Turbine350 bar
K-SCFT-060-22-07
Backordered
POR
130 mmFlow meter± 1 % IR80 °C62190CEOil based hydraulic fluids1600 gHigh Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CFactory calibration according to ISO 90013...60 l/minG3/4 BSPPBSPPTurbine350 bar
K-SCFT-150-02-02
Backordered
POR
121 mmFlow meter analogue± 1 % IR90 °C62190 mmCEOil based hydraulic fluids750High Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CFactory calibration according to ISO 90015...150 l/min3/4“ BSPPBSPPAnalogoue Turbine350 bar
K-SCFT-150-22-07
Backordered
POR
130 mmFlow meter± 1 % IR80 °C62190CEOil based hydraulic fluids1600 gHigh Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CFactory calibration according to ISO 90015...150 l/minG3/4 BSPPBSPPTurbine350 bar
K-SCFT-300-02-02
Backordered
POR
125 mmFlow meter analogue± 1 % IR90 °C62190 mmCEOil based hydraulic fluids1200High Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CFactory calibration according to ISO 90018...300 l/min1“ BSPPBSPPAnalogoue Turbine350 bar
K-SCFT-300-22-07
Backordered
POR
134 mmFlow meter± 1 % IR80 °C62190CEOil based hydraulic fluids1700 gHigh Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CFactory calibration according to ISO 90018...300 l/minG1 BSPPBSPPTurbine350 bar
K-SCFT-600-02-02
Backordered
POR
140 mmFlow meter analogue± 1 % IR90 °C62212 mmCEOil based hydraulic fluids1800High Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CFactory calibration according to ISO 900115...600 l/min1-1/4“ BSPPBSPPAnalogoue Turbine290 bar
K-SCFT-600-22-07
Backordered
POR
149 mmFlow meter± 1 % IR80 °C62212CEOil based hydraulic fluids2700 gHigh Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CFactory calibration according to ISO 900115...600 l/minG1 1/4 BSPPBSPPTurbine290 bar
K-SCFT-750-02-02
Backordered
POR
143 mmFlow meter analogue± 1 % IR90 °C100212 mmCEOil based hydraulic fluids2100High Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CFactory calibration according to ISO 900120...750 l/min1-7/8“ UNFUNFAnalogoue Turbine400 bar
K-SCFT-800-22-07
Backordered
POR
152 mmFlow meter± 1 % IR80 °C100212CEOil based hydraulic fluids5000 gHigh Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CFactory calibration according to ISO 900120...800 l/minG1 7/8 UNFUNFTurbine400 bar
K-SCFTT-015-C2-05
Backordered
POR
105 mmFlow meter CAN± 1 % FS90 °C37136 mmCEOil based hydraulic fluids650 gHigh Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CFactory calibration according to ISO 90011…015 l/min1/2“ BSPPBSPPCAN Turbine350 bar
K-SCFTT-060-C2-05
Backordered
POR
118 mmFlow meter CAN± 1 % IR90 °C62190 mmCEOil based hydraulic fluids750 gHigh Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CFactory calibration according to ISO 90013…060 l/min3/4“ BSPPBSPPCAN Turbine350 bar
K-SCFTT-150-C2-05
Backordered
POR
118 mmFlow meter CAN± 1 % IR90 °C62190 mmCEOil based hydraulic fluids750 gHigh Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CFactory calibration according to ISO 90015...150 l/min3/4“ BSPPBSPPCAN Turbine350 bar
K-SCFTT-300-C2-05
Backordered
POR
119 mmFlow meter CAN± 1 % IR90 °C62190 mmCEOil based hydraulic fluids1200 gHigh Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CFactory calibration according to ISO 90018...300 l/min1“ BSPPBSPPCAN Turbine350 bar
K-SCFTT-600-C2-05
Backordered
POR
137 mmFlow meter CAN± 1 % IR90 °C62212 mmCEOil based hydraulic fluids1800 gHigh Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CFactory calibration according to ISO 900115...600 l/min1-1/4“ BSPPBSPPCAN Turbine290 bar
K-SCFTT-750-C2-05
Backordered
POR
141 mmFlow meter CAN± 1 % IR90 °C100212 mmCEOil based hydraulic fluids2100 gHigh Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CFactory calibration according to ISO 900120...750 l/min1-7/8“ UNFUNFCAN Turbine400 bar
SCFT-015-02-02
Backordered
POR
108 mmFlow meter analogue± 1 % FS90 °C37136 mmCEOil based hydraulic fluids650High Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CNone1…015 l/min1/2“ BSPPBSPPAnalogoue Turbine350 bar
SCFT-015-22-07
Backordered
POR
115 mmFlow meter± 1 % FS80 °C37136 mmCEOil based hydraulic fluids700 gHigh Pressure Connectors Europe Division-20 °CHigh Pressure Connectors Europe Division-10...+50 °CNone1...15 l/minG1/2 BSPPBSPPTurbine350 bar