• Availability & Price
  • Search SKU
Filter by attributes
  • Ambient Temperature
  • Application
  • Brand
  • Connection Type
  • Depth
  • Division
  • Division
  • Electrical Requirements
  • Flow Rate
  • Height
More Filters...

WVM Series Large Flow Low Energy Vacuum Regenerated Compressed Air Dryer

Picture for category WVM Series Large Flow Low Energy Vacuum Regenerated Compressed Air Dryer

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker Generation 5 WVM compressed air dryers provide an energy efficient heat regenerated compressed air drying solution for large scale compressed air applications. Ideal for electronics and automotive production plants but suitable for all general manufacturing industries where typically high volume flows and low pressure dewpoints are required.

Providing energy savings of up to 25% compared to conventional systems, WVM series compressed air dryers can be equipped with heat exchangers that allow steam or other available process heat sources to be used for heat regeneration. This alternative regeneration process can be employed in addition to or instead of the standard electrical heaters, resulting in even higher energy savings.

Features:
• Constant outlet dewpoint in accordance with ISO8573-1 classes 1, 2 or 3 for water vapour & -40°C PDP (other PDP: -20°C / -70°C on request)
• Full feature electronic control with dewpoint display and Energy Saving Technology fitted as standard
• Large flow capacities
• Active heating under vacuum
• Various options for optimal adaptability to customer needs
• Basic thermal insulation fitted as standard (high performance additional option required for PDP greater than -40°C)

Benefits:
• Low energy costs
• No process air loss
• Regeneration under vacuum further improves energy efficiency
• Low regeneration temperature

WVM series compressed air dryers combine highest quality and reliability with the added peace of mind of being covered by a two year extended warranty scheme*, as well as being backed by a variety of global approvals.

*For details on extended warranty, please see www.polewr.com.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceDivisionTechnologyNoise LevelProduct SeriesConnection TypeDivisionAmbient TemperatureIngress Protection RatingProduct TypeWeightIndustrySpecifications MetDepthApplicationOperating TemperatureISO GradeProduct StyleOperating PressureWidthElectrical RequirementsPressure Dew PointBrandHeightOptionsFlow RatePort Size
W125/11VM5-F400CT
Backordered
POR
Gas Separation and Filtration Division EMEAFiltration80 to 85 dBAWVM 5FlangedGas Separation and Filtration Division EMEA40.0 °C MaximumIP54 Indoor Use OnlyCompressed Air Dryer2977 inchIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> PharmaceuticalsPED 2014/68/EU Fluid Group II56 inchCompressed Air Applications5 to 40 °CStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2Low Energy - Vacuum Regenerated58 to 145 psig1692.0 mmStandard: 400V 3ph 50Hz<br/><br/>Options on request.Options: -70°C (-100°F) or -20°C (-4°F)PARKER85 inchHigh Performance Insulation for PDP <-40°C1170 m³/h @ 7 barg (689 cfm @ 102 psig)DN 80
W155/11VM5-F400CT
Backordered
POR
Gas Separation and Filtration Division EMEAFiltration80 to 85 dBAWVM 5FlangedGas Separation and Filtration Division EMEA104.0 °F MaximumIP54 Indoor Use OnlyCompressed Air Dryer1460 mmIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> PharmaceuticalsPED 2014/68/EU Fluid Group II1412.0 mmCompressed Air Applications41 to 104 °FStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2Low Energy - Vacuum Regenerated4 to 11 barg67 inchStandard: 400V 3ph 50Hz<br/><br/>Options on request.Options: -70°C (-100°F) or -20°C (-4°F)PARKER91 inchHigh Performance Insulation for PDP <-40°C1470 m³/h ) @ 7 barg (865 cfm @ 102 psig)DN 80
W210/11VM5-F400CT
Backordered
POR
Gas Separation and Filtration Division EMEAFiltration80 to 85 dBAWVM 5FlangedGas Separation and Filtration Division EMEA104.0 °F MaximumIP54 Indoor Use OnlyCompressed Air Dryer4123 inchIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> PharmaceuticalsPED 2014/68/EU Fluid Group II56 inchCompressed Air Applications41 to 104 °FStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2Low Energy - Vacuum Regenerated58 to 145 psig67 inchStandard: 400V 3ph 50Hz<br/><br/>Options on request.Options: -70°C (-100°F) or -20°C (-4°F)PARKER108 inchHigh Performance Insulation for PDP <-40°C2050 m³/h @ 7 barg (1207 cfm @ 102 psig)DN 80
W310/11VM5-F400CT
Backordered
POR
Gas Separation and Filtration Division EMEAFiltration80 to 85 dBAWVM 5FlangedGas Separation and Filtration Division EMEA40.0 °C MaximumIP54 Indoor Use OnlyCompressed Air Dryer5755 inchIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> PharmaceuticalsPED 2014/68/EU Fluid Group II1702.0 mmCompressed Air Applications41 to 104 °FStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2Low Energy - Vacuum Regenerated58 to 145 psig2115.0 mmStandard: 400V 3ph 50Hz<br/><br/>Options on request.Standard: -40°C (-40°F)<br/>PARKER106 inchHigh Performance Insulation for PDP <-40°C3050 m³/h @ 7 barg (1795 cfm @ 102 psig)DN 100
W370/11VM5-F400CT
Backordered
POR
Gas Separation and Filtration Division EMEAFiltration80 to 85 dBAWVM 5FlangedGas Separation and Filtration Division EMEA104.0 °F MaximumIP54 Indoor Use OnlyCompressed Air Dryer6395 inchIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> PharmaceuticalsPED 2014/68/EU Fluid Group II67 inchCompressed Air Applications5 to 40 °CStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2Low Energy - Vacuum Regenerated58 to 145 psig2115.0 mmStandard: 400V 3ph 50Hz<br/><br/>Options on request.Standard: -40°C (-40°F)<br/>PARKER118 inchHigh Performance Insulation for PDP <-40°C3700 m³/h @ 7 barg (2178 cfm @ 102 psig)DN 100
W45/11VM5-F400CT
Backordered
POR
Gas Separation and Filtration Division EMEAFiltration80 to 85 dBAWVM 5FlangedGas Separation and Filtration Division EMEA104.0 °F MaximumIP54 Indoor Use OnlyCompressed Air Dryer1698 inchIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> PharmaceuticalsPED 2014/68/EU Fluid Group II48 inchCompressed Air Applications41 to 104 °FStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2Low Energy - Vacuum Regenerated4 to 11 barg1222.0 mmStandard: 400V 3ph 50Hz<br/><br/>Options on request.Options: -70°C (-100°F) or -20°C (-4°F)PARKER80 inchHigh Performance Insulation for PDP <-40°C450 m³/h @ 7 barg (265 cfm @ 102 psig)DN 50
W520/11VM5-F400CT
Backordered
POR
Gas Separation and Filtration Division EMEAFiltration80 to 85 dBAWVM 5FlangedGas Separation and Filtration Division EMEA40.0 °C MaximumIP54 Indoor Use OnlyCompressed Air Dryer4275 mmIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> PharmaceuticalsPED 2014/68/EU Fluid Group II1910.0 mmCompressed Air Applications5 to 40 °CStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2Low Energy - Vacuum Regenerated58 to 145 psig102 inchStandard: 400V 3ph 50Hz<br/><br/>Options on request.Options: -70°C (-100°F) or -20°C (-4°F)PARKER3210.0 mmHigh Performance Insulation for PDP <-40°C5050 m³/h @ 7 barg (2972 cfm @ 102 psig)DN 150
W60/11VM5-F400CT
Backordered
POR
Gas Separation and Filtration Division EMEAFiltration80 to 85 dBAWVM 5FlangedGas Separation and Filtration Division EMEA40.0 °C MaximumIP54 Indoor Use OnlyCompressed Air Dryer800 mmIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> PharmaceuticalsPED 2014/68/EU Fluid Group II1219.0 mmCompressed Air Applications5 to 40 °CStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2Low Energy - Vacuum Regenerated58 to 145 psig48 inchStandard: 400V 3ph 50Hz<br/><br/>Options on request.Options: -70°C (-100°F) or -20°C (-4°F)PARKER80 inchHigh Performance Insulation for PDP <-40°C610 m³/h @ 7 barg (359 cfm @ 102 psig)DN 50
W615/11VM5-F400CT
Backordered
POR
Gas Separation and Filtration Division EMEAFiltration80 to 85 dBAWVM 5FlangedGas Separation and Filtration Division EMEA104.0 °F MaximumIP54 Indoor Use OnlyCompressed Air Dryer4735 mmIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> PharmaceuticalsPED 2014/68/EU Fluid Group II1910.0 mmCompressed Air Applications5 to 40 °CStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2Low Energy - Vacuum Regenerated58 to 145 psig102 inchStandard: 400V 3ph 50Hz<br/><br/>Options on request.Options: -70°C (-100°F) or -20°C (-4°F)PARKER136 inchHigh Performance Insulation for PDP <-40°C6050 m³/h @ 7 barg (3561 cfm @ 102 psig)DN 150
W750/11VM5-F400CT
Backordered
POR
Gas Separation and Filtration Division EMEAFiltration80 to 85 dBAWVM 5FlangedGas Separation and Filtration Division EMEA104.0 °F MaximumIP54 Indoor Use OnlyCompressed Air Dryer5380 mmIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> PharmaceuticalsPED 2014/68/EU Fluid Group II79 inchCompressed Air Applications41 to 104 °FStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2Low Energy - Vacuum Regenerated4 to 11 barg110 inchStandard: 400V 3ph 50Hz<br/><br/>Options on request.Options: -70°C (-100°F) or -20°C (-4°F)PARKER137 inchHigh Performance Insulation for PDP <-40°C7300 m³/h @ 7 barg (4297 cfm @ 102 psig)DN 150
W80/11VM5-F400CT
Backordered
POR
Gas Separation and Filtration Division EMEAFiltration80 to 85 dBAWVM 5FlangedGas Separation and Filtration Division EMEA40.0 °C MaximumIP54 Indoor Use OnlyCompressed Air Dryer1985 inchIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> PharmaceuticalsPED 2014/68/EU Fluid Group II1219.0 mmCompressed Air Applications5 to 40 °CStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2Low Energy - Vacuum Regenerated58 to 145 psig48 inchStandard: 400V 3ph 50Hz<br/><br/>Options on request.Options: -70°C (-100°F) or -20°C (-4°F)PARKER2379.0 mmHigh Performance Insulation for PDP <-40°C800 m³/h @ 7 barg (471 cfm @ 102 psig)DN 50

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains