The direct operated proportional DC valves series D1FC (NG06/ CETOP 03) and D3FC (NG10/CETOP 05) with digital onboard electronics and position feedback provides optimized process speed with high dynamics and flow for various applications. The LVDT is completely integrated into the compact housing,  therefore it does not require an exposed cable connection. Thus an unintended disconnection is impossible. The digital onboard electronics is situated in a robust metal housing, which allows the usage under rough environmental conditions. The nominal values are factory set. The cable connection to a serial RS232 interface is available as accessory.

Optionally available with EtherCAT® interface
The D1FC and D3FC with EtherCAT® interface  fulfill the requirements  of  modern communication between valve and main control. Due to high data transmission speed and short cycle times, also demanding control functions can be realized within the fieldbus system.

The valve is actuated and monitored by the EtherCAT® interface. Actual value (spool position), temperature, operating hours and different error messages are available as diagnostic signals. The valve parameters are factory set  and can be adapted with the Parker ProPxD software via the parametrizing interface.

In addition to the fieldbus communication, the valves provide the range of functions of the standard version including  analogue  command  signal  and  diagnostic  spare stroke. Thus they can be operated independent of the fieldbus control, particularly during commissioning and maintenance.

Markets:
• Industrial
• Power generation
• Machine tools
• Molding
• Rubber & tire processing

Features/benefits:
• High level of dynamics and flows - optimized process speed
• Very good repeatability - improved process and product accuracy
• Fully integrated position feedback system - protection from mechanical external influences, resulting in lower down times
• Position feedback sensor positioned directly on the spool - very precise measurements, resulting in improved process accuracy
• Digital electronics - can be easily adapted to the application, resulting in flexible use
• Short delivery time - no storage necessary
• Compact dimensions - for use in particularly confined conditions
• With EtherCAT® interface upon request - high data speeds, short cycle times
• Progressive flow characteristics for sensitive adjustment

Applications:
• Machine tool
• General presses
• Tire presses
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceFunctionMaximum Flow RateDivisionMaximum Operating PressureSeal MaterialBody MaterialMounting PositionMinimum Fluid TemperatureMaximum Ambient TemperatureMaximum Kinematic ViscosityMinimum Ambient TemperatureActuation TypeFor Fluid TypeMinimum Kinematic ViscosityFilter Efficiency RatingMaximum Fluid TemperatureMounting StyleElectronics TypeIngress Protection RatingVariation of Opening PointPower Supply VoltageHysteresisVibration ResistanceResponse TimeLeak RateSeal MaterialPort ConnectionMarkingFlow RateConnection TypeSpool TypeSignal InputFunctionSignal OutputDefined Spool Position At Power DownSpool CodeBrandFlow RateMounting TypeTechnologyOperation TypeMediaWeightApplicationValve TypeDivisionProduct SeriesPressure DifferentialSpool Design
D3FCE50SB9NB03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barNBRCast IronUnrestricted-25 °C60 °C400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V< 0,1 %15 Shock Acc. IEC 68-2-2740 ms<1000 (zerolap spool)NBRNG10 / CETOP 05Standard55 l/min6 + PEZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VP to BE50, equal metering, 4-way, 3 position, all ports open, metered
D3FCE50SB9NB73
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barNBRCast IronUnrestricted-25 °C60 °C400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V< 0,1 %15 Shock Acc. IEC 68-2-2740 ms<1000 (zerolap spool)NBRNG10 / CETOP 05Standard55 l/min6 + PE + enableZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VP to BE50, equal metering, 4-way, 3 position, all ports open, metered
D3FCE50SB9VS03XG183
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barFPMCast IronUnrestricted-20 °C60 °C400 cSt-20 °CProportionalWater-Glycol20 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V< 0,1 %10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-3640 ms<1000 (zerolap spool)FPMNG10 / CETOP 05Standard55 l/min6 + PEZerolap4 to 20 mA12 to 20 mA = P-A4...20mAP to BE50, equal metering, 4-way, 3 position, all ports open, meteredPARKERn/aSubplateHydraulicsDirectHydraulic Oil7.7 kgIndustrial HydraulicProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve5 barSpool/body
D3FCE50SC9NB73
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barNBRCast IronUnrestricted-25 °C60 °C400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V< 0,1 %15 Shock Acc. IEC 68-2-2740 ms<1000 (zerolap spool)NBRNG10 / CETOP 05Standard55 l/min6 + PE + enableZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VnaE50, equal metering, 4-way, 3 position, all ports open, metered
D3FCE50UA9NB03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barNBRCast IronUnrestricted-25 °C60 °C400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V< 0,1 %10 Sinus 5...2000 Hz Acc. IEC 68-2-640 ms<1000 (zerolap spool)NBRNG10 / CETOP 05Standard75 l/min6 + PEZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VP to AE50, equal metering, 4-way, 3 position, all ports open, meteredSubplateDirect7.7 kgProportional DC Valve5 barSpool/body
D3FCE50UA9NB73
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barNBRCast IronUnrestricted-25 °C60 °C400 cSt-20 °CSolenoidHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V< 0,1 %15 Shock Acc. IEC 68-2-2740 ms<1000 (zerolap spool)NBRNG10 / CETOP 05Standard75 l/min6 + PE + enableZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VP to AE50, equal metering, 4-way, 3 position, all ports open, meteredSubplateDirect7.7 kgProportional DC Valve5 barSpool/body
D3FCE50UB9NB03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barNBRCast IronUnrestricted-25 °C60 °C400 cSt-20 °CProportionalHydraulic Oil20 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V< 0,1 %10 (RMS) Random Noise 20...200040 ms<1000 (zerolap spool)NBRNG10 / CETOP 05Standard75 l/min6 + PEZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VP to BE50, equal metering, 4-way, 3 position, all ports open, meteredSubplateDirect7.7 kgProportional DC Valve5 barSpool/body
D3FCE50UB9NB73
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barNBRCast IronUnrestricted-25 °C60 °C400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V< 0,1 %10 Sinus 5...2000 Hz Acc. IEC 68-2-640 ms<1000 (zerolap spool)NBRNG10 / CETOP 05Standard75 l/min6 + PE + enableZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VP to BE50, equal metering, 4-way, 3 position, all ports open, meteredSubplateDirect7.7 kgProportional DC Valve5 barSpool/body
D3FCE50UB9NS03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barNBRCast IronUnrestricted-25 °C60 °C400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V< 0,1 %10 Sinus 5...2000 Hz Acc. IEC 68-2-640 ms<1000 (zerolap spool)NBRNG10 / CETOP 05Standard75 l/min6 + PEZerolap4 to 20 mA12 to 20 mA = P-A+10...0...-10 VP to BE50, equal metering, 4-way, 3 position, all ports open, meteredSubplateDirect7.7 kgProportional DC Valve5 barSpool/body
D3FCE50UB9NS03XG183
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barNBRCast IronUnrestricted-25 °C60 °C400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V< 0,1 %15 Shock Acc. IEC 68-2-2740 ms<1000 (zerolap spool)NBRNG10 / CETOP 05Standard75 l/min6 + PEZerolap4 to 20 mA12 to 20 mA = P-A4...20mAP to BE50, equal metering, 4-way, 3 position, all ports open, meteredPARKERn/aSubplateHydraulicsDirectHydraulic Oil7.7 kgIndustrial HydraulicProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve5 barSpool/body
D3FCE50UC9NS03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barNBRCast IronUnrestricted-25 °C60 °C400 cSt-20 °CSolenoidHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V< 0,1 %10 Sinus 5...2000 Hz Acc. IEC 68-2-640 ms<1000 (zerolap spool)NBRNG10 / CETOP 05Standard75 l/min6 + PEZerolap4 to 20 mA12 to 20 mA = P-A+10...0...-10 VCenter positionE50, equal metering, 4-way, 3 position, all ports open, meteredSubplateDirect7.7 kgProportional DC Valve5 barSpool/body