Direct Operated Proportional Directional Control Valve - Series D1FC / D3FC

Picture for category Direct Operated Proportional Directional Control Valve - Series D1FC / D3FC

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The direct operated proportional DC valves series D1FC (NG06/ CETOP 03) and D3FC (NG10/CETOP 05) with digital onboard electronics and position feedback provides optimized process speed with high dynamics and flow for various applications. The LVDT is completely integrated into the compact housing,  therefore it does not require an exposed cable connection. Thus an unintended disconnection is impossible. The digital onboard electronics is situated in a robust metal housing, which allows the usage under rough environmental conditions. The nominal values are factory set. The cable connection to a serial RS232 interface is available as accessory.

Optionally available with EtherCAT® interface
The D1FC and D3FC with EtherCAT® interface  fulfill the requirements  of  modern communication between valve and main control. Due to high data transmission speed and short cycle times, also demanding control functions can be realized within the fieldbus system.

The valve is actuated and monitored by the EtherCAT® interface. Actual value (spool position), temperature, operating hours and different error messages are available as diagnostic signals. The valve parameters are factory set  and can be adapted with the Parker ProPxD software via the parametrizing interface.

In addition to the fieldbus communication, the valves provide the range of functions of the standard version including  analogue  command  signal  and  diagnostic  spare stroke. Thus they can be operated independent of the fieldbus control, particularly during commissioning and maintenance.

Markets:
• Industrial
• Power generation
• Machine tools
• Molding
• Rubber & tire processing

Features/benefits:
• High level of dynamics and flows - optimized process speed
• Very good repeatability - improved process and product accuracy
• Fully integrated position feedback system - protection from mechanical external influences, resulting in lower down times
• Position feedback sensor positioned directly on the spool - very precise measurements, resulting in improved process accuracy
• Digital electronics - can be easily adapted to the application, resulting in flexible use
• Short delivery time - no storage necessary
• Compact dimensions - for use in particularly confined conditions
• With EtherCAT® interface upon request - high data speeds, short cycle times
• Progressive flow characteristics for sensitive adjustment

Applications:
• Machine tool
• General presses
• Tire presses
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceFunctionMaximum Flow RateDivisionMaximum Operating PressureMounting TypeSeal MaterialBody MaterialOperation TypeMounting PositionWeightMinimum Fluid TemperatureMaximum Ambient TemperatureMaximum Kinematic ViscosityMinimum Ambient TemperatureActuation TypeFor Fluid TypeMinimum Kinematic ViscosityFilter Efficiency RatingProduct SeriesMaximum Fluid TemperatureMounting StyleElectronics TypeIngress Protection RatingVariation of Opening PointPower Supply VoltagePressure DifferentialHysteresisSpool DesignVibration ResistanceLeak RateResponse TimeSeal MaterialPort ConnectionMarkingConnection TypeSpool TypeDefined Spool Position At Power DownSpool CodeSignal InputFunctionSignal OutputFlow RateBrandFlow RateTechnologyMediaApplicationValve TypeDivision
D3FCB31SC9NS03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRCast IronDirectUnrestricted7.7 kg-25 °C60 °C400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar< 0,1 %Spool/body15 Shock Acc. IEC 68-2-27<100 (overlap spool)40 msNBRNG10 / CETOP 05Standard6 + PEOverlapCenter positionB31, 2:1 metering, 4-way, 3 position, all ports open4 to 20 mA12 to 20 mA = P-A+10...0...-10 V27 / 55 L/MIN
D3FCB31SC9NS73
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRCast IronDirectUnrestricted7.7 kg-25 °C60 °C400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar< 0,1 %Spool/body10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36<100 (overlap spool)40 msNBRNG10 / CETOP 05Standard6 + PE + enableOverlapCenter positionB31, 2:1 metering, 4-way, 3 position, all ports open4 to 20 mA12 to 20 mA = P-A+10...0...-10 V27 / 55 L/MIN
D3FCB31SC9VB03
Backordered
POR
Industrial Systems Division EuropeDirectDIN 24340 / ISO 4401 / CETOP RP121 / NFPAFPMNG10 / CETOP 05Standard6 + PEOverlapCenter positionB31, 2:1 metering, 4-way, 3 position, all ports open0 to ±10 V0 to 10 V = P-A+10...0...-10 V27 / 55 L/MIN
D3FCB31SC9VS03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barFPMCast IronUnrestricted-20 °C60 °C400 cSt-20 °CProportionalWater-Glycol20 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V< 0,1 %10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36<100 (overlap spool)40 msFPMNG10 / CETOP 05Standard6 + PEOverlapCenter positionB31, 2:1 metering, 4-way, 3 position, all ports open4 to 20 mA12 to 20 mA = P-A+10...0...-10 V27 / 55 L/MIN
D3FCB31UC9NB03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRCast IronDirectUnrestricted7.7 kg-25 °C60 °C400 cSt-20 °CSolenoidHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar< 0,1 %Spool/body10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36<100 (overlap spool)40 msNBRNG10 / CETOP 05Standard6 + PEOverlapCenter positionB31, 2:1 metering, 4-way, 3 position, all ports open0 to ±10 V0 to 10 V = P-A+10...0...-10 V37 / 75 L/MIN
D3FCB31UC9VB03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateFPMCast IronDirectUnrestricted7.7 kg-20 °C60 °C400 cSt-20 °CProportionalWater-Glycol20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar< 0,1 %Spool/body10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36<100 (overlap spool)40 msFPMNG10 / CETOP 05Standard6 + PEOverlapCenter positionB31, 2:1 metering, 4-way, 3 position, all ports open0 to ±10 V0 to 10 V = P-A+10...0...-10 V37 / 75 L/MIN
D3FCB32MC9NB03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRCast IronDirectUnrestricted7.7 kg-25 °C60 °C400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar< 0,1 %Spool/body15 Shock Acc. IEC 68-2-27<100 (overlap spool)40 msNBRNG10 / CETOP 05Standard6 + PEOverlapCenter positionB32, 2:1 metering, 4-way, 3 position, A + B bleed to T, metered, P port blocked0 to ±10 V0 to 10 V = P-A+10...0...-10 V17 / 35 L/MIN
D3FCB32MC9NS03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRCast IronDirectUnrestricted7.7 kg-25 °C60 °C400 cSt-20 °CSolenoidHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar< 0,1 %Spool/body10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36<100 (overlap spool)40 msNBRNG10 / CETOP 05Standard6 + PEOverlapCenter positionB32, 2:1 metering, 4-way, 3 position, A + B bleed to T, metered, P port blocked4 to 20 mA12 to 20 mA = P-A+10...0...-10 V17 / 35 L/MIN
D3FCB32MC9VB03
Backordered
POR
Industrial Systems Division EuropeDirectDIN 24340 / ISO 4401 / CETOP RP121 / NFPAFPMNG10 / CETOP 05Standard6 + PEOverlapCenter positionB32, 2:1 metering, 4-way, 3 position, A + B bleed to T, metered, P port blocked0 to ±10 V0 to 10 V = P-A+10...0...-10 V17 / 35 L/MIN
D3FCB32MC9VS03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateFPMCast IronDirectUnrestricted7.7 kg-20 °C60 °C400 cSt-20 °CSolenoidWater-Glycol20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar< 0,1 %Spool/body10 Sinus 5...2000 Hz Acc. IEC 68-2-6<100 (overlap spool)40 msFPMNG10 / CETOP 05Standard6 + PEOverlapCenter positionB32, 2:1 metering, 4-way, 3 position, A + B bleed to T, metered, P port blocked4 to 20 mA12 to 20 mA = P-A+10...0...-10 V17 / 35 L/MIN
D3FCB32MC9VS03XG183
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateFPMCast IronDirectUnrestricted7.7 kg-20 °C60 °C400 cSt-20 °CProportionalWater-Glycol20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar< 0,1 %Spool/body10 Sinus 5...2000 Hz Acc. IEC 68-2-6<100 (overlap spool)40 msFPMNG10 / CETOP 05Standard6 + PEOverlapCenter positionB32, 2:1 metering, 4-way, 3 position, A + B bleed to T, metered, P port blocked4 to 20 mA12 to 20 mA = P-A4...20mA17 / 35 L/MINPARKERn/aHydraulicsHydraulic OilIndustrial HydraulicProportional DC ValveIndustrial Systems Division Europe
D3FCB32SC9NB03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRCast IronDirectUnrestricted7.7 kg-25 °C60 °C400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar< 0,1 %Spool/body10 Sinus 5...2000 Hz Acc. IEC 68-2-6<100 (overlap spool)40 msNBRNG10 / CETOP 05Standard6 + PEOverlapCenter positionB32, 2:1 metering, 4-way, 3 position, A + B bleed to T, metered, P port blocked0 to ±10 V0 to 10 V = P-A+10...0...-10 V27 / 55 L/MIN
D3FCB32SC9NB73
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRCast IronDirectUnrestricted7.7 kg-25 °C60 °C400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar< 0,1 %Spool/body15 Shock Acc. IEC 68-2-27<100 (overlap spool)40 msNBRNG10 / CETOP 05Standard6 + PE + enableOverlapCenter positionB32, 2:1 metering, 4-way, 3 position, A + B bleed to T, metered, P port blocked0 to ±10 V0 to 10 V = P-A+10...0...-10 V27 / 55 L/MIN
D3FCB32SC9NE03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRCast IronDirectUnrestricted7.7 kg-25 °C60 °C400 cSt-20 °CSolenoidHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar< 0,1 %Spool/body10 Sinus 5...2000 Hz Acc. IEC 68-2-6<100 (overlap spool)40 msNBRNG10 / CETOP 05Standard6 + PEOverlapCenter positionB32, 2:1 metering, 4-way, 3 position, A + B bleed to T, metered, P port blocked0 to ±20 mA0 to 20 mA = P-A+10...0...-10 V27 / 55 L/MIN
D3FCB32SC9NS03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRCast IronDirectUnrestricted7.7 kg-25 °C60 °C400 cSt-20 °CSolenoidHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar< 0,1 %Spool/body10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36<100 (overlap spool)40 msNBRNG10 / CETOP 05Standard6 + PEOverlapCenter positionB32, 2:1 metering, 4-way, 3 position, A + B bleed to T, metered, P port blocked4 to 20 mA12 to 20 mA = P-A+10...0...-10 V27 / 55 L/MIN
D3FCB32SC9NS03XG183
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRCast IronDirectUnrestricted7.7 kg-25 °C60 °C400 cSt-20 °CSolenoidHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar< 0,1 %Spool/body15 Shock Acc. IEC 68-2-27<100 (overlap spool)40 msNBRNG10 / CETOP 05Standard6 + PEOverlapCenter positionB32, 2:1 metering, 4-way, 3 position, A + B bleed to T, metered, P port blocked4 to 20 mA12 to 20 mA = P-A4...20mA27 / 55 L/MINPARKERn/aHydraulicsHydraulic OilIndustrial HydraulicProportional DC ValveIndustrial Systems Division Europe
D3FCB32SC9NS73
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barNBRCast IronUnrestricted-25 °C60 °C400 cSt-20 °CSolenoidHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V< 0,1 %15 Shock Acc. IEC 68-2-27<100 (overlap spool)40 msNBRNG10 / CETOP 05Standard6 + PE + enableOverlapCenter positionB32, 2:1 metering, 4-way, 3 position, A + B bleed to T, metered, P port blocked4 to 20 mA12 to 20 mA = P-A+10...0...-10 V27 / 55 L/MIN
D3FCB32SC9VS03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateFPMCast IronDirectUnrestricted7.7 kg-20 °C60 °C400 cSt-20 °CProportionalWater-Glycol20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar< 0,1 %Spool/body10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36<100 (overlap spool)40 msFPMNG10 / CETOP 05Standard6 + PEOverlapCenter positionB32, 2:1 metering, 4-way, 3 position, A + B bleed to T, metered, P port blocked4 to 20 mA12 to 20 mA = P-A+10...0...-10 V27 / 55 L/MIN
D3FCB32SC9VS03XG183
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateFPMCast IronDirectUnrestricted7.7 kg-20 °C60 °C400 cSt-20 °CProportionalWater-Glycol20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar< 0,1 %Spool/body10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36<100 (overlap spool)40 msFPMNG10 / CETOP 05Standard6 + PEOverlapCenter positionB32, 2:1 metering, 4-way, 3 position, A + B bleed to T, metered, P port blocked4 to 20 mA12 to 20 mA = P-A4...20mA27 / 55 L/MINPARKERn/aHydraulicsHydraulic OilIndustrial HydraulicProportional DC ValveIndustrial Systems Division Europe
D3FCB32UC9NB03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRCast IronDirectUnrestricted7.7 kg-25 °C60 °C400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar< 0,1 %Spool/body10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36<100 (overlap spool)40 msNBRNG10 / CETOP 05Standard6 + PEOverlapCenter positionB32, 2:1 metering, 4-way, 3 position, A + B bleed to T, metered, P port blocked0 to ±10 V0 to 10 V = P-A+10...0...-10 V37 / 75 L/MIN