Direct Operated Proportional Directional Control Valve - Series D1FC / D3FC

Picture for category Direct Operated Proportional Directional Control Valve - Series D1FC / D3FC

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The direct operated proportional DC valves series D1FC (NG06/ CETOP 03) and D3FC (NG10/CETOP 05) with digital onboard electronics and position feedback provides optimized process speed with high dynamics and flow for various applications. The LVDT is completely integrated into the compact housing,  therefore it does not require an exposed cable connection. Thus an unintended disconnection is impossible. The digital onboard electronics is situated in a robust metal housing, which allows the usage under rough environmental conditions. The nominal values are factory set. The cable connection to a serial RS232 interface is available as accessory.

Optionally available with EtherCAT® interface
The D1FC and D3FC with EtherCAT® interface  fulfill the requirements  of  modern communication between valve and main control. Due to high data transmission speed and short cycle times, also demanding control functions can be realized within the fieldbus system.

The valve is actuated and monitored by the EtherCAT® interface. Actual value (spool position), temperature, operating hours and different error messages are available as diagnostic signals. The valve parameters are factory set  and can be adapted with the Parker ProPxD software via the parametrizing interface.

In addition to the fieldbus communication, the valves provide the range of functions of the standard version including  analogue  command  signal  and  diagnostic  spare stroke. Thus they can be operated independent of the fieldbus control, particularly during commissioning and maintenance.

Markets:
• Industrial
• Power generation
• Machine tools
• Molding
• Rubber & tire processing

Features/benefits:
• High level of dynamics and flows - optimized process speed
• Very good repeatability - improved process and product accuracy
• Fully integrated position feedback system - protection from mechanical external influences, resulting in lower down times
• Position feedback sensor positioned directly on the spool - very precise measurements, resulting in improved process accuracy
• Digital electronics - can be easily adapted to the application, resulting in flexible use
• Short delivery time - no storage necessary
• Compact dimensions - for use in particularly confined conditions
• With EtherCAT® interface upon request - high data speeds, short cycle times
• Progressive flow characteristics for sensitive adjustment

Applications:
• Machine tool
• General presses
• Tire presses
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceFunctionMaximum Flow RateDivisionMaximum Operating PressureMounting TypeSeal MaterialFor Fluid TypeBody MaterialOperation TypeMounting PositionMaximum Ambient TemperatureMaximum Kinematic ViscosityMinimum Ambient TemperatureActuation TypeMinimum Fluid TemperatureWeightMinimum Kinematic ViscosityFilter Efficiency RatingProduct SeriesMaximum Fluid TemperatureMounting StyleElectronics TypeIngress Protection RatingVariation of Opening PointPower Supply VoltagePressure DifferentialLeak RateHysteresisSpool DesignResponse TimeVibration ResistanceSeal MaterialMarkingPort ConnectionFlow RateConnection TypeSpool TypeDefined Spool Position At Power DownSignal InputFunctionSignal OutputSpool Code
D1FCE01FC9VB73
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateFPMWater-GlycolCast IronDirectUnrestricted60 °C400 cSt-20 °CProportional-20 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36FPMStandardNG06 / CETOP 0310 l/min6 + PE + enableOverlapCenter position0 to ±10 V0 to 10 V = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01FC9VE03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateFPMWater-GlycolCast IronDirectUnrestricted60 °C400 cSt-20 °CProportional-20 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36FPMStandardNG06 / CETOP 0310 l/min6 + PEOverlapCenter position0 to ±20 mA0 to 20 mA = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01FC9VS03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateFPMWater-GlycolCast IronDirectUnrestricted60 °C400 cSt-20 °CSolenoid-20 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms15 ShockFPMStandardNG06 / CETOP 0310 l/min6 + PEOverlapCenter position4 to 20 mA12 to 20 mA = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01HC9NB03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535Cast IronDirectUnrestricted60 °C400 cSt-20 °CSolenoid-25 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms10 Sinus 5...2000 Hz Acc. IEC 68-2-6NBRStandardNG06 / CETOP 0320 l/min6 + PEOverlapCenter position0 to ±10 V0 to 10 V = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01HC9NB73
1 in stock
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535Cast IronDirectUnrestricted60 °C400 cSt-20 °CProportional-25 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms15 Shock Acc. IEC 68-2-27NBRStandardNG06 / CETOP 0320 l/min6 + PE + enableOverlapCenter position0 to ±10 V0 to 10 V = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01HC9NE03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535Cast IronDirectUnrestricted60 °C400 cSt-20 °CSolenoid-25 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36NBRStandardNG06 / CETOP 0320 l/min6 + PEOverlapCenter position0 to ±20 mA0 to 20 mA = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01HC9NE53
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barNBRHydraulic Oil According to DIN 51524 ... 535Cast IronUnrestricted60 °C400 cSt-20 °CProportional-25 °C20 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V<50 (overlap spool)< 0,1 %20 ms15 Shock Acc. IEC 68-2-27NBRStandardNG06 / CETOP 0320 l/min11 + PEOverlapCenter position0 to ±20 mA0 to 20 mA = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01HC9NE73
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535Cast IronDirectUnrestricted60 °C400 cSt-20 °CProportional-25 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36NBRStandardNG06 / CETOP 0320 l/min6 + PE + enableOverlapCenter position0 to ±20 mA0 to 20 mA = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01HC9NS03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535Cast IronDirectUnrestricted60 °C400 cSt-20 °CProportional-25 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36NBRStandardNG06 / CETOP 0320 l/min6 + PEOverlapCenter position4 to 20 mA12 to 20 mA = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01HC9NS73
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535Cast IronDirectUnrestricted60 °C400 cSt-20 °CProportional-25 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms15 Shock Acc. IEC 68-2-27NBRStandardNG06 / CETOP 0320 l/min6 + PE + enableOverlapCenter position4 to 20 mA12 to 20 mA = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01HC9VB03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateFPMWater-GlycolCast IronDirectUnrestricted60 °C400 cSt-20 °CSolenoid-20 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms15 Shock Acc. IEC 68-2-27FPMStandardNG06 / CETOP 0320 l/min6 + PEOverlapCenter position0 to ±10 V0 to 10 V = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01HC9VB53
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateFPMWater-GlycolCast IronDirectUnrestricted60 °C400 cSt-20 °CSolenoid-20 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms15 Shock Acc. IEC 68-2-27FPMStandardNG06 / CETOP 0320 l/min11 + PEOverlapCenter position0 to ±10 V0 to 10 V = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01HC9VS03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateFPMWater-GlycolCast IronDirectUnrestricted60 °C400 cSt-20 °CSolenoid-20 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36FPMStandardNG06 / CETOP 0320 l/min6 + PEOverlapCenter position4 to 20 mA12 to 20 mA = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01KC9NB03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535Cast IronDirectUnrestricted60 °C400 cSt-20 °CSolenoid-25 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms15 Shock Acc. IEC 68-2-27NBRStandardNG06 / CETOP 0330 l/min6 + PEOverlapCenter position0 to ±10 V0 to 10 V = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01KC9NB73
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535Cast IronDirectUnrestricted60 °C400 cSt-20 °CSolenoid-25 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms15 Shock Acc. IEC 68-2-27NBRStandardNG06 / CETOP 0330 l/min6 + PE + enableOverlapCenter position0 to ±10 V0 to 10 V = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01KC9NE03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535Cast IronDirectUnrestricted60 °C400 cSt-20 °CSolenoid-25 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36NBRStandardNG06 / CETOP 0330 l/min6 + PEOverlapCenter position0 to ±20 mA0 to 20 mA = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01KC9NE73
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535Cast IronDirectUnrestricted60 °C400 cSt-20 °CProportional-25 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms15 Shock Acc. IEC 68-2-27NBRStandardNG06 / CETOP 0330 l/min6 + PE + enableOverlapCenter position0 to ±20 mA0 to 20 mA = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01KC9NS03
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535Cast IronDirectUnrestricted60 °C400 cSt-20 °CSolenoid-25 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36NBRStandardNG06 / CETOP 0330 l/min6 + PEOverlapCenter position4 to 20 mA12 to 20 mA = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01KC9NS53
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535Cast IronDirectUnrestricted60 °C400 cSt-20 °CProportional-25 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36NBRStandardNG06 / CETOP 0330 l/min11 + PEOverlapCenter position4 to 20 mA12 to 20 mA = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open
D1FCE01KC9NS73
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535Cast IronDirectUnrestricted60 °C400 cSt-20 °CProportional-25 °C3.4 kg20 cStISO 4406; 18/16/13Proportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboardIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V5 bar<50 (overlap spool)< 0,1 %Spool/body20 ms10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36NBRStandardNG06 / CETOP 0330 l/min6 + PE + enableOverlapCenter position4 to 20 mA12 to 20 mA = P-A+10...0...-10 VE01, equal metering, 4-way, 3 position, all ports open