Directional Control Valve - D1VW Series(AP)

Picture for category Directional Control Valve - D1VW Series(AP)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The directional control valve series D1VW in NG06 (CETOP 03 / NFPA D03) provides high functional limits up to 80 l/min in combination with a very low, energy-saving pressure drop due to optimized flow passages. The maximum pressure is 350 bar.

A wide variety of spools and options allows to design an unlimited number of hydraulic circuits. The D1VW is available with a soft shift option for smooth operation. An additional orifice in the solenoid anchor dampens the shifting time.

Markets:
• Industrial

Features/Benefits:
• Compact, proven design that represents our long-term experience in hydraulics
• Wide range of spools - fits all hydraulic systems
• Shortest lead time - no warehousing necessary
• Optional soft shift option - for smooth operation
• Optional manual override

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceInterface TypeIngress Protection RatingActuation TypeBody MaterialSizeWeightMaximum Operating PressureMaximum Operating TemperatureProduct TypeMaximum Flow RateMinimum Operating TemperatureDivisionSolenoid OptionMaterial - SealsConnection TypeSpool CodeSpool PositionInput VoltageProduct Series
SD1VW030DNJW
Backordered
POR
DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidGray IronDIN NG06 / CETOP 03 / NFPA D03 nom2.1 kgP, A, B: 350; T: 210 bar60 °CDirectional Spool Valve80 (depending on spool, see shift limits) L/min-25 °CControl Division ChinaOmit - Manual Override (standard)N - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)030D - 2 positions, operated in position a or b, no center or offset position24 VDCS Series
SD1VW030DNTW
Backordered
POR
DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidGray IronDIN NG06 / CETOP 03 / NFPA D03 nom2.1 kgP, A, B: 350; T: 140 bar60 °CDirectional Spool Valve80 (depending on spool, see shift limits) L/min-25 °CControl Division ChinaOmit - Manual Override (standard)N - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)030D - 2 positions, operated in position a or b, no center or offset position230V 50Hz / 240V 60HzS Series
SD1VW030DVJW
Backordered
POR
DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidGray IronDIN NG06 / CETOP 03 / NFPA D03 nom2.1 kgP, A, B: 350; T: 210 bar60 °CDirectional Spool Valve80 (depending on spool, see shift limits) L/min-25 °CControl Division ChinaOmit - Manual Override (standard)V - FKMConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)030D - 2 positions, operated in position a or b, no center or offset position24 VDCS Series
SD1VW030DVTW
Backordered
POR
DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidGray IronDIN NG06 / CETOP 03 / NFPA D03 nom2.1 kgP, A, B: 350; T: 140 bar60 °CDirectional Spool Valve80 (depending on spool, see shift limits) L/min-25 °CControl Division ChinaOmit - Manual Override (standard)V - FKMConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)030D - 2 positions, operated in position a or b, no center or offset position230V 50Hz / 240V 60HzS Series
SD1VW030HNJW
Backordered
POR
DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidGray IronDIN NG06 / CETOP 03 / NFPA D03 nom1.5 kgP, A, B: 350; T: 210 bar60 °CDirectional Spool Valve80 (depending on spool, see shift limits) L/min-25 °CControl Division ChinaOmit - Manual Override (standard)N - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)030H - 2 positions, spring offset in position a, operated in position b24 VDCS Series
SD1VW030HNKW
Backordered
POR
DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidGray IronDIN NG06 / CETOP 03 / NFPA D03 nom1.5 kgP, A, B: 350; T: 210 bar60 °CDirectional Spool Valve80 (depending on spool, see shift limits) L/min-25 °CControl Division ChinaOmit - Manual Override (standard)N - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)030H - 2 positions, spring offset in position a, operated in position b12 VDCS Series
SD1VW030HNTW
Backordered
POR
DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidGray IronDIN NG06 / CETOP 03 / NFPA D03 nom1.5 kgP, A, B: 350; T: 140 bar60 °CDirectional Spool Valve80 (depending on spool, see shift limits) L/min-25 °CControl Division ChinaOmit - Manual Override (standard)N - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)030H - 2 positions, spring offset in position a, operated in position b230V 50Hz / 240V 60HzS Series
SD1VW034CNJW
Backordered
POR
DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidGray IronDIN NG06 / CETOP 03 / NFPA D03 nom2.1 kgP, A, B: 350; T: 210 bar60 °CDirectional Spool Valve80 (depending on spool, see shift limits) L/min-25 °CControl Division ChinaOmit - Manual Override (standard)N - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)034C - 3 positions, spring offset in position 0, operated in position a or b24 VDCS Series
SD1VW083BNJW
Backordered
POR
DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidGray IronDIN NG06 / CETOP 03 / NFPA D03 nom1.5 kgP, A, B: 350; T: 210 bar60 °CDirectional Spool Valve80 (depending on spool, see shift limits) L/min-25 °CControl Division ChinaOmit - Manual Override (standard)N - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)083B - 2 positions, spring offset in position b, operated in position a24 VDCS Series