Picture for category Directional Control Valve - D1VW Series(AP)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The directional control valve series D1VW in NG06 (CETOP 03 / NFPA D03) provides high functional limits up to 80 l/min in combination with a very low, energy-saving pressure drop due to optimized flow passages. The maximum pressure is 350 bar.

A wide variety of spools and options allows to design an unlimited number of hydraulic circuits. The D1VW is available with a soft shift option for smooth operation. An additional orifice in the solenoid anchor dampens the shifting time.

Markets:
• Industrial

Features/Benefits:
• Compact, proven design that represents our long-term experience in hydraulics
• Wide range of spools - fits all hydraulic systems
• Shortest lead time - no warehousing necessary
• Optional soft shift option - for smooth operation
• Optional manual override

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceDivisionProduct TypeSolenoid OptionIngress Protection RatingActuation TypeInterface TypeBody MaterialMinimum Operating TemperatureSizeMaximum Operating TemperatureWeightMaximum Operating PressureMaximum Flow RateInput VoltageProduct SeriesMaterial - SealsConnection TypeSpool PositionSpool Code
SD1VW010CNJW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgP, A, B: 350; T: 210 bar80 (depending on spool, see shift limits) L/min24 VDCS SeriesN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b010
SD1VW010CNTW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgP, A, B: 350; T: 140 bar80 (depending on spool, see shift limits) L/min230V 50Hz / 240V 60HzS SeriesN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b010
SD1VW010CVTW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgP, A, B: 350; T: 140 bar80 (depending on spool, see shift limits) L/min230V 50Hz / 240V 60HzS SeriesV - FKMConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b010
SD1VW010KNJW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgP, A, B: 350; T: 210 bar80 (depending on spool, see shift limits) L/min24 VDCS SeriesN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)K - 2 positions, spring offset in position 0, operated in position b010
SD1VW011CNJW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgP, A, B: 350; T: 210 bar80 (depending on spool, see shift limits) L/min24 VDCS SeriesN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b011
SD1VW011CNTW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgP, A, B: 350; T: 140 bar80 (depending on spool, see shift limits) L/min230V 50Hz / 240V 60HzS SeriesN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b011
SD1VW011CNYW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgP, A, B: 350; T: 140 bar80 (depending on spool, see shift limits) L/min110V 50 Hz / 120V 60 HzS SeriesN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b011
SD1VW011CVJW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgP, A, B: 350; T: 210 bar80 (depending on spool, see shift limits) L/min24 VDCS SeriesV - FKMConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b011
SD1VW014CNJW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgP, A, B: 350; T: 210 bar80 (depending on spool, see shift limits) L/min24 VDCS SeriesN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b014
SD1VW014CNKW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgP, A, B: 350; T: 210 bar80 (depending on spool, see shift limits) L/min12 VDCS SeriesN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b014
SD1VW014CNTW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgP, A, B: 350; T: 140 bar80 (depending on spool, see shift limits) L/min230V 50Hz / 240V 60HzS SeriesN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b014
SD1VW014CNYW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgP, A, B: 350; T: 140 bar80 (depending on spool, see shift limits) L/min110V 50 Hz / 120V 60 HzS SeriesN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b014
SD1VW014ENJW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgP, A, B: 350; T: 210 bar80 (depending on spool, see shift limits) L/min24 VDCS SeriesN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a014
SD1VW014ENTW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgP, A, B: 350; T: 140 bar80 (depending on spool, see shift limits) L/min230V 50Hz / 240V 60HzS SeriesN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a014
SD1VW014EVJW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgP, A, B: 350; T: 210 bar80 (depending on spool, see shift limits) L/min24 VDCS SeriesV - FKMConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a014
SD1VW014EVTW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgP, A, B: 350; T: 140 bar80 (depending on spool, see shift limits) L/min230V 50Hz / 240V 60HzS SeriesV - FKMConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a014
SD1VW015CNJW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgP, A, B: 350; T: 210 bar80 (depending on spool, see shift limits) L/min24 VDCS SeriesN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b015
SD1VW015CNTW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgP, A, B: 350; T: 140 bar80 (depending on spool, see shift limits) L/min230V 50Hz / 240V 60HzS SeriesN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b015
SD1VW015ENJW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgP, A, B: 350; T: 210 bar80 (depending on spool, see shift limits) L/min24 VDCS SeriesN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a015
SD1VW015ENTW
Backordered
POR
Control Division ChinaDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgP, A, B: 350; T: 140 bar80 (depending on spool, see shift limits) L/min230V 50Hz / 240V 60HzS SeriesN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a015

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains