• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Connection Type
  • Division
  • Ingress Protection Rating
  • Input Voltage
  • Interface Type
  • Material - Seals
  • Maximum Flow Rate
  • Maximum Operating Pressure
More Filters...

Directional Control Valve - D1VW Series(AP)

Picture for category Directional Control Valve - D1VW Series(AP)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The directional control valve series D1VW in NG06 (CETOP 03 / NFPA D03) provides high functional limits up to 80 l/min in combination with a very low, energy-saving pressure drop due to optimized flow passages. The maximum pressure is 350 bar.

A wide variety of spools and options allows to design an unlimited number of hydraulic circuits. The D1VW is available with a soft shift option for smooth operation. An additional orifice in the solenoid anchor dampens the shifting time.

Markets:
• Industrial

Features/Benefits:
• Compact, proven design that represents our long-term experience in hydraulics
• Wide range of spools - fits all hydraulic systems
• Shortest lead time - no warehousing necessary
• Optional soft shift option - for smooth operation
• Optional manual override

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceMaximum Flow RateDivisionMaximum Operating PressureProduct TypeSolenoid OptionIngress Protection RatingActuation TypeInterface TypeBody MaterialMinimum Operating TemperatureSizeMaximum Operating TemperatureWeightSpool PositionProduct SeriesSpool CodeMaterial - SealsInput VoltageConnection Type
SD1VW002ENYW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 140 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgE - 2 positions, spring offset in position 0, operated in position aS Series002N - NBR110V 50 Hz / 120V 60 HzConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW002FNJW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 210 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgF - 2 positions, Spring offset in position b, operated in position 0S Series002N - NBR24 VDCConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW002FNYW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 140 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgF - 2 positions, Spring offset in position b, operated in position 0S Series002N - NBR110V 50 Hz / 120V 60 HzConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW002KNJW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 210 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgK - 2 positions, spring offset in position 0, operated in position bS Series002N - NBR24 VDCConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW002KNKW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 210 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgK - 2 positions, spring offset in position 0, operated in position bS Series002N - NBR12 VDCConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW002KNTW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 140 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgK - 2 positions, spring offset in position 0, operated in position bS Series002N - NBR230V 50Hz / 240V 60HzConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW002KNYW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 140 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgK - 2 positions, spring offset in position 0, operated in position bS Series002N - NBR110V 50 Hz / 120V 60 HzConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW002KVJW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 210 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgK - 2 positions, spring offset in position 0, operated in position bS Series002V - FKM24 VDCConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW003CNJW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 210 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgC - 3 positions, spring offset in position 0, operated in position a or bS Series003N - NBR24 VDCConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW003KNJW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 210 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgK - 2 positions, spring offset in position 0, operated in position bS Series003N - NBR24 VDCConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW004CNJW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 210 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgC - 3 positions, spring offset in position 0, operated in position a or bS Series004N - NBR24 VDCConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW004CNKW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 210 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgC - 3 positions, spring offset in position 0, operated in position a or bS Series004N - NBR12 VDCConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW004CNTW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 140 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgC - 3 positions, spring offset in position 0, operated in position a or bS Series004N - NBR230V 50Hz / 240V 60HzConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW004CNYW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 140 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgC - 3 positions, spring offset in position 0, operated in position a or bS Series004N - NBR110V 50 Hz / 120V 60 HzConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW004CVJW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 210 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgC - 3 positions, spring offset in position 0, operated in position a or bS Series004V - FKM24 VDCConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW004CVTW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 140 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C2.1 kgC - 3 positions, spring offset in position 0, operated in position a or bS Series004V - FKM230V 50Hz / 240V 60HzConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW004ENJW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 210 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgE - 2 positions, spring offset in position 0, operated in position aS Series004N - NBR24 VDCConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW004ENTW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 140 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgE - 2 positions, spring offset in position 0, operated in position aS Series004N - NBR230V 50Hz / 240V 60HzConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW004EVJW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 210 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgE - 2 positions, spring offset in position 0, operated in position aS Series004V - FKM24 VDCConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)
SD1VW004FNJW
Backordered
POR
80 (depending on spool, see shift limits) L/minControl Division ChinaP, A, B: 350; T: 210 barDirectional Spool ValveOmit - Manual Override (standard)IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)SolenoidDIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Gray Iron-25 °CDIN NG06 / CETOP 03 / NFPA D03 nom60 °C1.5 kgF - 2 positions, Spring offset in position b, operated in position 0S Series004N - NBR24 VDCConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains