• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Connection Type
  • Division
  • Ingress Protection Rating
  • Input Voltage
  • Interface Type
  • Material - Seals
  • Maximum Flow Rate
  • Maximum Operating Pressure
More Filters...

Directional Control Valve - D3W Series(AP)

Picture for category Directional Control Valve - D3W Series(AP)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s direct operated directional control valve series D3W in NG10 (CETOP 05/ NFPA D05) features low energy losses due to optimized flow passages for economical operation. It offers high functional limits up to 150 l/min and a maximum pressure of 350 bar. The wide variety of options includes soft shift anchor tubes for smooth operation.

Market:
• Industrial

Features/Benefits:
• Compact, proven design that represents our long-term experience in hydraulics
• High functional limits – low forces resulting in safe operation also at high flow rates
• Low pressure drop – resulting in low energy losses in operation
• Wide range of spools - fits all hydraulic systems
• Shortest lead time - no warehousing necessary
• Also available as 5-chamber valve (D3DW) for high tank pressure and extreme flow conditions

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceMaximum Flow RateMaximum Operating TemperatureDivisionProduct TypeSolenoid OptionSizeIngress Protection RatingWeightActuation TypeMinimum Operating TemperatureBody MaterialMaximum Operating PressureInterface TypeMaterial - SealsInput VoltageProduct SeriesSpool CodeConnection TypeSpool Position
SD3W001CVJW
Backordered
POR
150(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)6.3 kgSolenoid-25 °CGray IronP, A, B: 350; T: 210 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05V - FKM24 VDCS Series001Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b
SD3W001CVTW
Backordered
POR
115(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)6.3 kgSolenoid-25 °CGray IronP, A, B: 350; T: 105 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05V - FKM230V 50Hz / 240V 60HzS Series001Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b
SD3W001CVYW
Backordered
POR
115(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)6.3 kgSolenoid-25 °CGray IronP, A, B: 350; T: 105 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05V - FKM110V 50 Hz / 120V 60 HzS Series001Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b
SD3W001ENJW
Backordered
POR
150(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)4.8 kgSolenoid-25 °CGray IronP, A, B: 350; T: 210 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05N - NBR24 VDCS Series001Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a
SD3W001ENKW
Backordered
POR
150(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)4.8 kgSolenoid-25 °CGray IronP, A, B: 350; T: 210 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05N - NBR12 VDCS Series001Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a
SD3W001ENTW
Backordered
POR
115(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)4.8 kgSolenoid-25 °CGray IronP, A, B: 350; T: 105 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05N - NBR230V 50Hz / 240V 60HzS Series001Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a
SD3W001EVJW
Backordered
POR
150(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)4.8 kgSolenoid-25 °CGray IronP, A, B: 350; T: 210 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05V - FKM24 VDCS Series001Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a
SD3W001EVTW
Backordered
POR
115(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)4.8 kgSolenoid-25 °CGray IronP, A, B: 350; T: 105 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05V - FKM230V 50Hz / 240V 60HzS Series001Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a
SD3W001FNJW
Backordered
POR
150(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)4.8 kgSolenoid-25 °CGray IronP, A, B: 350; T: 210 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05N - NBR24 VDCS Series001Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)F - 2 positions, Spring offset in position b, operated in position 0
SD3W001FVJW
Backordered
POR
150(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)4.8 kgSolenoid-25 °CGray IronP, A, B: 350; T: 210 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05V - FKM24 VDCS Series001Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)F - 2 positions, Spring offset in position b, operated in position 0
SD3W001KNJW
Backordered
POR
150(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)4.8 kgSolenoid-25 °CGray IronP, A, B: 350; T: 210 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05N - NBR24 VDCS Series001Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)K - 2 positions, spring offset in position 0, operated in position b
SD3W001KNTW
Backordered
POR
115(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)4.8 kgSolenoid-25 °CGray IronP, A, B: 350; T: 105 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05N - NBR230V 50Hz / 240V 60HzS Series001Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)K - 2 positions, spring offset in position 0, operated in position b
SD3W002CNJW
Backordered
POR
150(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)6.3 kgSolenoid-25 °CGray IronP, A, B: 350; T: 210 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05N - NBR24 VDCS Series002Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b
SD3W002CNKW
Backordered
POR
150(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)6.3 kgSolenoid-25 °CGray IronP, A, B: 350; T: 210 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05N - NBR12 VDCS Series002Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b
SD3W002CNTW
Backordered
POR
115(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)6.3 kgSolenoid-25 °CGray IronP, A, B: 350; T: 105 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05N - NBR230V 50Hz / 240V 60HzS Series002Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b
SD3W002CNYW
Backordered
POR
115(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)6.3 kgSolenoid-25 °CGray IronP, A, B: 350; T: 105 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05N - NBR110V 50 Hz / 120V 60 HzS Series002Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b
SD3W002CVJW
Backordered
POR
150(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)6.3 kgSolenoid-25 °CGray IronP, A, B: 350; T: 210 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05V - FKM24 VDCS Series002Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b
SD3W002ENJW
Backordered
POR
150(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)4.8 kgSolenoid-25 °CGray IronP, A, B: 350; T: 210 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05N - NBR24 VDCS Series002Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a
SD3W002ENKW
Backordered
POR
150(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)4.8 kgSolenoid-25 °CGray IronP, A, B: 350; T: 210 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05N - NBR12 VDCS Series002Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a
SD3W002ENTW
Backordered
POR
115(depending on spool, see shift limits) L/min50 °CControl Division ChinaDirectional Spool ValveOmit - Manual Override (standard)DIN NG10 / CETOP 05 / NFPA D05 nomIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)4.8 kgSolenoid-25 °CGray IronP, A, B: 350; T: 105 barDIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05N - NBR230V 50Hz / 240V 60HzS Series002Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains