*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Action | SKU | Availability | Price | Function | Actuation Type | Minimum Operating Temperature | Division | Maximum Operating Temperature | Maximum Operating Pressure | Mounting Type | Seal Material | For Fluid Type | Body Material | Operation Type | Mounting Position | Weight | Maximum Flow Rate | Product Series | Seal Material | Marking | Port Connection | Solenoid Connection | Spool Code | Spool Position | Signal Input | Solenoid Option | Nominal Size | Corrosion Resistance Included |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
D1MW002KNJWW1P | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Unrestricted | 1.5 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | EN 175301-803 | 002 | 2 positions, spring offset in position 0, operated in position b | 24 V | Extended manual override with rubber cover | NG06 / CETOP 03 | Anti corrosion coating | |
D1MW003CNJA | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Preferably Horizontal | 2.1 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 2-pin AMP Junior Timer | 003 | 3 positions, spring offset in position 0, operated in position a or b | 24 V | Standard solenoid | NG06 / CETOP 03 | Standard surface protection | |
D1MW004CNJA | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Preferably Horizontal | 2.1 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 2-pin AMP Junior Timer | 004 | 3 positions, spring offset in position 0, operated in position a or b | 24 V | Standard solenoid | NG06 / CETOP 03 | Standard surface protection | |
D1MW004CNJAW | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Unrestricted | 2.1 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 2-pin AMP Junior Timer | 004 | 3 positions, spring offset in position 0, operated in position a or b | 24 V | Extended manual override with rubber cover | NG06 / CETOP 03 | Standard surface protection | |
D1MW004CNJJ | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Unrestricted | 2.1 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | DT04-2P | 004 | 3 positions, spring offset in position 0, operated in position a or b | 24 V | Standard solenoid | NG06 / CETOP 03 | Standard surface protection | |
D1MW004CNJJ1P | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Unrestricted | 2.1 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | DT04-2P | 004 | 3 positions, spring offset in position 0, operated in position a or b | 24 V | Standard solenoid | NG06 / CETOP 03 | Anti corrosion coating | |
D1MW004CNJJW | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Unrestricted | 2.1 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | DT04-2P | 004 | 3 positions, spring offset in position 0, operated in position a or b | 24 V | Extended manual override with rubber cover | NG06 / CETOP 03 | Standard surface protection | |
D1MW004CNJJW1P | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Preferably Horizontal | 2.1 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | DT04-2P | 004 | 3 positions, spring offset in position 0, operated in position a or b | 24 V | Extended manual override with rubber cover | NG06 / CETOP 03 | Anti corrosion coating | |
D1MW004CNJW1P | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Unrestricted | 2.1 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | EN 175301-803 | 004 | 3 positions, spring offset in position 0, operated in position a or b | 24 V | Standard solenoid | NG06 / CETOP 03 | Anti corrosion coating | |
D1MW004CNJWW | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Preferably Horizontal | 2.1 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | EN 175301-803 | 004 | 3 positions, spring offset in position 0, operated in position a or b | 24 V | Extended manual override with rubber cover | NG06 / CETOP 03 | Standard surface protection | |
D1MW004CNJWW1P | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Preferably Horizontal | 2.1 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | EN 175301-803 | 004 | 3 positions, spring offset in position 0, operated in position a or b | 24 V | Extended manual override with rubber cover | NG06 / CETOP 03 | Anti corrosion coating | |
D1MW004CNKA | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Preferably Horizontal | 2.1 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 2-pin AMP Junior Timer | 004 | 3 positions, spring offset in position 0, operated in position a or b | 12 V | Standard solenoid | NG06 / CETOP 03 | Standard surface protection | |
D1MW004CNKJ | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Unrestricted | 2.1 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | DT04-2P | 004 | 3 positions, spring offset in position 0, operated in position a or b | 12 V | Standard solenoid | NG06 / CETOP 03 | Standard surface protection | |
D1MW004CNKJ1P | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Preferably Horizontal | 2.1 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | DT04-2P | 004 | 3 positions, spring offset in position 0, operated in position a or b | 12 V | Standard solenoid | NG06 / CETOP 03 | Anti corrosion coating | |
D1MW004CNKW1P | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Preferably Horizontal | 2.1 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | EN 175301-803 | 004 | 3 positions, spring offset in position 0, operated in position a or b | 12 V | Standard solenoid | NG06 / CETOP 03 | Anti corrosion coating | |
D1MW004CNKWW | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Preferably Horizontal | 2.1 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | EN 175301-803 | 004 | 3 positions, spring offset in position 0, operated in position a or b | 12 V | Extended manual override with rubber cover | NG06 / CETOP 03 | Standard surface protection | |
D1MW004CNKWW1P | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Preferably Horizontal | 1.5 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | EN 175301-803 | 004 | 3 positions, spring offset in position 0, operated in position a or b | 12 V | Extended manual override with rubber cover | NG06 / CETOP 03 | Anti corrosion coating | |
D1MW004CVJJW1P | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | FPM | Water-Glycol | Cast Iron | Direct | Unrestricted | 2.1 kg | 80 L/min | Directional Control Valve | FPM | Standard | NG06 / CETOP 03 | DT04-2P | 004 | 3 positions, spring offset in position 0, operated in position a or b | 24 V | Extended manual override with rubber cover | NG06 / CETOP 03 | Anti corrosion coating | |
D1MW004CVJW1P | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | FPM | Water-Glycol | Cast Iron | Direct | Unrestricted | 2.1 kg | 80 L/min | Directional Control Valve | FPM | Standard | NG06 / CETOP 03 | EN 175301-803 | 004 | 3 positions, spring offset in position 0, operated in position a or b | 24 V | Standard solenoid | NG06 / CETOP 03 | Anti corrosion coating | |
D1MW004CVJWW | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | FPM | Water-Glycol | Cast Iron | Direct | Unrestricted | 2.1 kg | 80 L/min | Directional Control Valve | FPM | Standard | NG06 / CETOP 03 | EN 175301-803 | 004 | 3 positions, spring offset in position 0, operated in position a or b | 24 V | Extended manual override with rubber cover | NG06 / CETOP 03 | Standard surface protection |
REWARD Status
Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.