EPP4 electro pneumatic pressure regulator
range with integrated electronic system provides highest accuracy thanks to a high precision closed loop signal. The regulator is also designed to achieve the best reliability thanks to a piston concept.
Features/benefits:
-All parameters fully adjustable through the PC software Calys
-Easy to use software
-Long life expectancy
-Compact and light
-Limited inventory
-Low power
-Low hysteresis
-High reliability (air <50µm)
Markets:
- Industrial
- Process

Industries:
- Welding
- Speed and brake control
- Sanding
- Cutting
- Humidification
- Tension regulation
- Painting
- Presses
- Polishing
- Adaptative suspension control
- Robotics
- Paper industry
- Machine tools
Read More...
View as Grid List
Sort by
Display per page
Action SKU Availability Price Specifications Met Hysteresis Power Consumption Power Supply Voltage ATEX Specifications Met Protection Mode Materials of Construction Maximum Pressure Differential Minimum Ambient Temperature Maximum Flow Rate Maximum Ambient Temperature Mounting Position Minimum Regulating Pressure Division Minimum Pressure Differential Vibration Resistance Options Control Signal For Fluid Type Maximum Regulating Pressure Port Size Electrical Connection Safety Features Filter Efficiency Rating Minimum Fluid Temperature Maximum Fluid Temperature Operational Life
P4BG2001A001
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 70 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) - 4 - 20 mA Lubricated or non lubricated air,neutral gases 4 bar 1/4&quot; BSP M12 - 4 pin; male connector communication
P4BG2001A002
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 70 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) - 0 - 10 V Lubricated or non lubricated air,neutral gases 10 bar 1/4&quot; BSP M12 - 4 pin; male connector communication
P4BG2001A003
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 70 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) - 4 - 20 mA Lubricated or non lubricated air,neutral gases 10 bar 1/4&quot; BSP M12 - 4 pin; male connector communication
P4BG2001A006
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 70 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) - 0 - 10 V Lubricated or non lubricated air,neutral gases 5 bar 1/4&quot; BSP M12 - 4 pin; male connector communication
P4BG2001A007
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 70 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) - 4 - 20 mA Lubricated or non lubricated air,neutral gases 5 bar 1/4&quot; BSP M12 - 4 pin; male connector communication
P4BG2001A008
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 70 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) - 0 - 10 V Lubricated or non lubricated air,neutral gases 7 bar 1/4&quot; BSP M12 - 4 pin; male connector communication
P4BG2001A009
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 70 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) - 4 - 20 mA Lubricated or non lubricated air,neutral gases 7 bar 1/4&quot; BSP M12 - 4 pin; male connector communication
P4BG2003A002
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 70 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) Integrated pilot exhaust 0 - 10 V Lubricated or non lubricated air,neutral gases 10 bar 1/4&quot; BSP M12 - 4 pin; male connector communication In case of control signal failure or if it is less than 50mV, the regulated pressure drops automatically to 0 bar (atmospheric pressure). In case of voltage supply failure, the regulated pressure will be kept constant. 50 MICRON 0 +50 &#176;C &gt; 50 Million changes of control signal steps
P4BG4001A002
Backordered
$2,416.92
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 150 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) - 0 - 10 V Lubricated or non lubricated air,neutral gases 10 bar 1/2&quot; BSP M12 - 4 pin; male connector communication
P4BG4001A003
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 150 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) - 4 - 20 mA Lubricated or non lubricated air,neutral gases 10 bar 1/2&quot; BSP M12 - 4 pin; male connector communication
P4BG4001A004
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 150 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) - 0 - 10 V Lubricated or non lubricated air,neutral gases 6 bar 1/2&quot; BSP M12 - 4 pin; male connector communication
P4BG4001A005
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 150 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) - 4 - 20 mA Lubricated or non lubricated air,neutral gases 6 bar 1/2&quot; BSP M12 - 4 pin; male connector communication
P4BG4004A010
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 150 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) External Pressure Supply 0 - 10 V Lubricated or non lubricated air,neutral gases, propane 4 bar 1/2&quot; BSP M12 - 4 pin; male connector communication
P4BG4051A002
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 150 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) - 4 - 20 mA Oxygen 10 bar 1/2&quot; BSP M12 - 4 pin; male connector communication
P4BG6101A002
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 6 W with 24 V DC and constant changes of the control signal, &lt; 2 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 1000 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) - 0 - 10 V Lubricated or non lubricated air,neutral gases 10 bar 1&quot; BSP M12 - 4 pin; male connector communication &gt; 20 Million changes of control signal steps
P4BG6101A003
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 6 W with 24 V DC and constant changes of the control signal, &lt; 2 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 1000 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) - 4 - 20 mA Lubricated or non lubricated air,neutral gases 10 bar 1&quot; BSP M12 - 4 pin; male connector communication &gt; 20 Million changes of control signal steps
P4BG9101A002
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 6 W with 24 V DC and constant changes of the control signal, &lt; 2 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 2700 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) - 0 - 10 V Lubricated or non lubricated air,neutral gases 10 bar 2&quot; BSP M12 - 4 pin; male connector communication &gt; 20 Million changes of control signal steps
P4BG9101A003
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 6 W with 24 V DC and constant changes of the control signal, &lt; 2 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 2700 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) - 4 - 20 mA Lubricated or non lubricated air,neutral gases 10 bar 2&quot; BSP M12 - 4 pin; male connector communication &gt; 20 Million changes of control signal steps
P4CG2001C002
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 70 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) - 4 - 20 mA Lubricated or non lubricated air,neutral gases 10 bar 1/4&quot; BSP M12 - 8 pin; male connector power supply/control signal 50 MICRON &gt; 50 Million changes of control signal steps
P4CG2001C005
Backordered
POR
EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 &#177; 50mbar (factory set up) Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 24V DC &#177; 15% (Max. ripple 1V) - IP65 Silicon free 12 bar 0 &#176;C 70 m3/hour +50 &#176;C Indifferent (recommended position: upright; electronic part on top) 0,05 bar Fluid and Climate Controls Europe 0 bar 30g (in all directions) - 0 - 10 V Lubricated or non lubricated air,neutral gases 7 bar 1/4&quot; BSP M12 - 8 pin; male connector power supply/control signal 50 MICRON &gt; 50 Million changes of control signal steps