• Availability & Price
  • Search SKU
Filter by attributes
  • ATEX Specifications Met
  • Control Signal
  • Division
  • Electrical Connection
  • Filter Efficiency Rating
  • For Fluid Type
  • Hysteresis
  • Materials of Construction
  • Maximum Ambient Temperature
  • Maximum Flow Rate
More Filters...

EPP4 Proportional Pressure Regulator

Picture for category EPP4 Proportional Pressure Regulator

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

EPP4 electro pneumatic pressure regulator
range with integrated electronic system provides highest accuracy thanks to a high precision closed loop signal. The regulator is also designed to achieve the best reliability thanks to a piston concept.
Features/benefits:
-All parameters fully adjustable through the PC software Calys
-Easy to use software
-Long life expectancy
-Compact and light
-Limited inventory
-Low power
-Low hysteresis
-High reliability (air <50µm)
Markets:
- Industrial
- Process

Industries:
- Welding
- Speed and brake control
- Sanding
- Cutting
- Humidification
- Tension regulation
- Painting
- Presses
- Polishing
- Adaptative suspension control
- Robotics
- Paper industry
- Machine tools
Read More...
View as Grid List
Sort by
Display per page
Action SKU Availability Price Minimum Regulating Pressure Division Operational Life Vibration Resistance Filter Efficiency Rating Specifications Met Power Supply Voltage Hysteresis Materials of Construction ATEX Specifications Met Protection Mode Minimum Pressure Differential Minimum Ambient Temperature Power Consumption Maximum Pressure Differential Maximum Flow Rate Mounting Position Maximum Ambient Temperature Options Control Signal For Fluid Type Maximum Regulating Pressure Electrical Connection Port Size
P4CG2001C006
Backordered
POR
0,05 bar Fluid and Climate Controls Europe &gt; 50 Million changes of control signal steps 30g (in all directions) 50 MICRON EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 24V DC &#177; 15% (Max. ripple 1V) &#177; 50mbar (factory set up) Silicon free - IP65 0 bar 0 &#176;C Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 12 bar 70 m3/hour Indifferent (recommended position: upright; electronic part on top) +50 &#176;C - 4 - 20 mA Lubricated or non lubricated air,neutral gases 7 bar M12 - 8 pin; male connector power supply/control signal 1/4&quot; BSP
P4CG4001C002
Backordered
POR
0,05 bar Fluid and Climate Controls Europe &gt; 50 Million changes of control signal steps 30g (in all directions) 50 MICRON EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 24V DC &#177; 15% (Max. ripple 1V) &#177; 50mbar (factory set up) Silicon free - IP65 0 bar 0 &#176;C Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 12 bar 150 m3/hour Indifferent (recommended position: upright; electronic part on top) +50 &#176;C - 4 - 20 mA Lubricated or non lubricated air,neutral gases 10 bar M12 - 8 pin; male connector power supply/control signal 1/2&quot; BSP
P4CG4001C006
Backordered
POR
0,05 bar Fluid and Climate Controls Europe &gt; 50 Million changes of control signal steps 30g (in all directions) 50 MICRON EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 24V DC &#177; 15% (Max. ripple 1V) &#177; 50mbar (factory set up) Silicon free - IP65 0 bar 0 &#176;C Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 12 bar 150 m3/hour Indifferent (recommended position: upright; electronic part on top) +50 &#176;C - 4 - 20 mA Lubricated or non lubricated air,neutral gases 7 bar M12 - 8 pin; male connector power supply/control signal 1/2&quot; BSP
P4CG4001C011
Backordered
POR
0,05 bar Fluid and Climate Controls Europe &gt; 50 Million changes of control signal steps 30g (in all directions) 50 MICRON EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 24V DC &#177; 15% (Max. ripple 1V) &#177; 50mbar (factory set up) Silicon free - IP65 0 bar 0 &#176;C Max. 2.8 W with 24 V DC and constant changes of the control signal &lt; 1.5 W without change of control signal 12 bar 150 m3/hour Indifferent (recommended position: upright; electronic part on top) +50 &#176;C - 0 - 10 V Lubricated or non lubricated air,neutral gases 5 bar M12 - 8 pin; male connector power supply/control signal 1/2&quot; BSP
P4CG4101D001
Backordered
POR
0,05 bar Fluid and Climate Controls Europe &gt; 50 Million changes of control signal steps 30g (in all directions) 50 MICRON EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 24V DC &#177; 15% (Max. ripple 1V) &#177; 50mbar (factory set up) Silicon free - IP65 0 bar 0 &#176;C Max. 6 W with 24 V DC and constant changes of the control signal, &lt; 2 W without change of control signal 21 bar 150 m3/hour Indifferent (recommended position: upright; electronic part on top) +50 &#176;C - 0 - 10 V Lubricated or non lubricated air,neutral gases 12 bar M12 - 8 pin; male connector power supply/control signal 1/2&quot; BSP
P4CG4201D003
Backordered
POR
0,05 bar Fluid and Climate Controls Europe &gt; 50 Million changes of control signal steps 30g (in all directions) 50 MICRON EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 24V DC &#177; 15% (Max. ripple 1V) ≤ 100 mbar if P inlet ≤ 10 bar&lt;br/&gt;≤ 200 mbar if P inlet &gt; 10 bar Silicon free - IP65 0 bar 0 &#176;C Max. 6 W with 24 V DC and constant changes of the control signal, &lt; 2 W without change of control signal 21 bar 150 m3/hour Indifferent (recommended position: upright; electronic part on top) +50 &#176;C - 0 - 10 V Lubricated or non lubricated air,neutral gases 20 bar M12 - 8 pin; male connector power supply/control signal 1/2&quot; BSP
P4CG4201D004
Backordered
POR
0,05 bar Fluid and Climate Controls Europe &gt; 50 Million changes of control signal steps 30g (in all directions) 50 MICRON EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 24V DC &#177; 15% (Max. ripple 1V) ≤ 100 mbar if P inlet ≤ 10 bar&lt;br/&gt;≤ 200 mbar if P inlet &gt; 10 bar Silicon free - IP65 0 bar 0 &#176;C Max. 6 W with 24 V DC and constant changes of the control signal, &lt; 2 W without change of control signal 21 bar 150 m3/hour Indifferent (recommended position: upright; electronic part on top) +50 &#176;C - 4 - 20 mA Lubricated or non lubricated air,neutral gases 20 bar M12 - 8 pin; male connector power supply/control signal 1/2&quot; BSP
P4CG4201D005
Backordered
POR
0,05 bar Fluid and Climate Controls Europe &gt; 50 Million changes of control signal steps 30g (in all directions) 50 MICRON EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 24V DC &#177; 15% (Max. ripple 1V) &#177; 50mbar (factory set up) Silicon free - IP65 0 bar 0 &#176;C Max. 6 W with 24 V DC and constant changes of the control signal, &lt; 2 W without change of control signal 21 bar 150 m3/hour Indifferent (recommended position: upright; electronic part on top) +50 &#176;C - 0 - 10 V Lubricated or non lubricated air,neutral gases 16 bar M12 - 8 pin; male connector power supply/control signal 1/2&quot; BSP
P4CG4461C002
Backordered
POR
0,05 bar Fluid and Climate Controls Europe &gt; 50 Million changes of control signal steps 30g (in all directions) 50 MICRON EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 24V DC &#177; 15% (Max. ripple 1V) ≤ 100 mbar Silicon free Ex II 3 G/D&lt;br/&gt;Ex nA IIC T4 Gc&lt;br/&gt;Ex tc IIIB T130&#176;C Dc IP65 0 bar 0 &#176;C Max. 6 W with 24 V DC and constant changes of the control signal, &lt; 2 W without change of control signal 12 bar 150 m3/hour Indifferent (recommended position: upright; electronic part on top) +50 &#176;C - 4-20 mA Lubricated or non lubricated air,neutral gases 10 bar M12 - 8 pin; male connector power supply/control signal 1/2&quot; BSP
P4CG6101C001
Backordered
POR
0,05 bar Fluid and Climate Controls Europe 30g (in all directions) 50 MICRON EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 24V DC &#177; 15% (Max. ripple 1V) ≤ 100 mbar if P inlet ≤ 10 bar&lt;br/&gt;≤ 200 mbar if P inlet &gt; 10 bar Silicon free - IP65 0 bar 0 &#176;C Max. 6 W with 24 V DC and constant changes of the control signal, &lt; 2 W without change of control signal 12 bar 1000 m3/hour Indifferent (recommended position: upright; electronic part on top) +50 &#176;C - 0 - 10 V Lubricated or non lubricated air,neutral gases 10 bar M12 - 8 pin; male connector power supply/control signal 1&quot; BSP
P4CG6101C002
Backordered
POR
0,05 bar Fluid and Climate Controls Europe 30g (in all directions) 50 MICRON EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 24V DC &#177; 15% (Max. ripple 1V) ≤ 100 mbar if P inlet ≤ 10 bar&lt;br/&gt;≤ 200 mbar if P inlet &gt; 10 bar Silicon free - IP65 0 bar 0 &#176;C Max. 6 W with 24 V DC and constant changes of the control signal, &lt; 2 W without change of control signal 12 bar 1000 m3/hour Indifferent (recommended position: upright; electronic part on top) +50 &#176;C - 4 - 20 mA Lubricated or non lubricated air,neutral gases 10 bar M12 - 8 pin; male connector power supply/control signal 1&quot; BSP
P4CG6101C009
Backordered
POR
0,05 bar Fluid and Climate Controls Europe 30g (in all directions) 50 MICRON EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 24V DC &#177; 15% (Max. ripple 1V) ≤ 100 mbar if P inlet ≤ 10 bar&lt;br/&gt;≤ 200 mbar if P inlet &gt; 10 bar Silicon free - IP65 0 bar 0 &#176;C Max. 6 W with 24 V DC and constant changes of the control signal, &lt; 2 W without change of control signal 12 bar 1000 m3/hour Indifferent (recommended position: upright; electronic part on top) +50 &#176;C - 4-20 mA Lubricated or non lubricated air,neutral gases 3,5 bar M12 - 8 pin; male connector power supply/control signal 1&quot; BSP
P4CG6101C011
Backordered
POR
0,05 bar Fluid and Climate Controls Europe 30g (in all directions) 50 MICRON EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 24V DC &#177; 15% (Max. ripple 1V) ≤ 100 mbar if P inlet ≤ 10 bar&lt;br/&gt;≤ 200 mbar if P inlet &gt; 10 bar Silicon free - IP65 0 bar 0 &#176;C Max. 6 W with 24 V DC and constant changes of the control signal, &lt; 2 W without change of control signal 12 bar 1000 m3/hour Indifferent (recommended position: upright; electronic part on top) +50 &#176;C - 0 - 10 V Lubricated or non lubricated air,neutral gases 5 bar M12 - 8 pin; male connector power supply/control signal 1&quot; BSP
P4CG6161C002
Backordered
POR
0,05 bar Fluid and Climate Controls Europe 30g (in all directions) 50 MICRON EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 24V DC &#177; 15% (Max. ripple 1V) ≤ 100 mbar Silicon free Ex II 3 G/D&lt;br/&gt;Ex nA IIC T4 Gc&lt;br/&gt;Ex tc IIIB T130&#176;C Dc IP65 0 bar 0 &#176;C Max. 6 W with 24 V DC and constant changes of the control signal, &lt; 2 W without change of control signal 12 bar 1000 m3/hour Indifferent (recommended position: upright; electronic part on top) +50 &#176;C - 4-20 mA Lubricated or non lubricated air,neutral gases 10 bar M12 - 8 pin; male connector power supply/control signal 1&quot; BSP
P4CG9101C001
Backordered
POR
0,05 bar Fluid and Climate Controls Europe 30g (in all directions) 50 MICRON EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 24V DC &#177; 15% (Max. ripple 1V) ≤ 100 mbar if P inlet ≤ 10 bar&lt;br/&gt;≤ 200 mbar if P inlet &gt; 10 bar Silicon free - IP65 0 bar 0 &#176;C Max. 6 W with 24 V DC and constant changes of the control signal, &lt; 2 W without change of control signal 12 bar 2700 m3/hour Indifferent (recommended position: upright; electronic part on top) +50 &#176;C - 0 - 10 V Lubricated or non lubricated air,neutral gases 10 bar M12 - 8 pin; male connector power supply/control signal 2&quot; BSP
P4CG9101C002
Backordered
POR
0,05 bar Fluid and Climate Controls Europe 30g (in all directions) 50 MICRON EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 24V DC &#177; 15% (Max. ripple 1V) ≤ 100 mbar if P inlet ≤ 10 bar&lt;br/&gt;≤ 200 mbar if P inlet &gt; 10 bar Silicon free - IP65 0 bar 0 &#176;C Max. 6 W with 24 V DC and constant changes of the control signal, &lt; 2 W without change of control signal 12 bar 2700 m3/hour Indifferent (recommended position: upright; electronic part on top) +50 &#176;C - 4 - 20 mA Lubricated or non lubricated air,neutral gases 10 bar M12 - 8 pin; male connector power supply/control signal 2&quot; BSP
P4CG9101C010
Backordered
POR
0,05 bar Fluid and Climate Controls Europe 30g (in all directions) 50 MICRON EN 61000-6-1: 2001 | EN 61000-6-2: 2001 | EN 61000-6-3: 2001 | EN61000-6-4:2001 24V DC &#177; 15% (Max. ripple 1V) ≤ 100 mbar if P inlet ≤ 10 bar&lt;br/&gt;≤ 200 mbar if P inlet &gt; 10 bar Silicon free - IP65 0 bar 0 &#176;C Max. 6 W with 24 V DC and constant changes of the control signal, &lt; 2 W without change of control signal 12 bar 2700 m3/hour Indifferent (recommended position: upright; electronic part on top) +50 &#176;C - 4-20 mA Lubricated or non lubricated air,neutral gases 6 bar M12 - 8 pin; male connector power supply/control signal 2&quot; BSP

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains