• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • ATEX Specifications Met
  • Body Material
  • Body Material
  • Coil Power Consumption
  • Coil Specifications Met
  • Coil Temperature Range
  • Division
  • Electrical Connection
  • Flow Coefficient 1
More Filters...

G Series direct and indirect acting Solenoid Valves for Industrial and Process applications

Picture for category G Series direct and indirect acting Solenoid Valves for Industrial and Process applications

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The G Series direct and indirect acting solenoid valves range includes many options to fullfill the demand of the most challenging applications in Industrial and Process markets. The range is designed to achieve the best in class robustness thanks to the reinforced diaphragm design and stainless steel operator rated for million of life cycles. This product solution can optimize the total ownership costs in a broad range of heavy duty and high demanding applications.

Markets:
- Industrial
- Process

Applications:
- Compressors and air treatment
- Fluid and gas control /handling
- Actuators control in safe ot harsh environment includin ATEX
- Water and steam controls
- Oil Burners

Features/Benefits:
- Wide range of electrical parts including VDE, UL and ATEX approvals
- No minimum pressure required for magnalift operated valves
- Lonf lyfe expectancy
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceDivisionMaximum Fluid TemperaturePort TypeSeat MaterialMinimum Operating PressureCoil Power ConsumptionCoil Temperature RangeFlow Coefficient 2Valve TypeInsulation ClassMediaOrifice SizeFunctionSeal MaterialSpecifications MetPower Supply VoltageCoil Specifications MetActuation TypeElectrical ConnectionATEX Specifications MetMinimum Fluid TemperaturePort SizeFlow Coefficient 1Maximum Operating Pressure
E121G2601
Backordered
POR
Fluid and Climate Controls Europe100 °CPipe MountingBrass0 bar---2/2 Way-Air, Inert Gases, Liquids14,5 mmNormally ClosedFKM---Direct Operated--0 °C3/4" G2800 Nl/min0,8 bar DC - 0,9 bar AC
E321G36
Backordered
POR
Fluid and Climate Controls Europe100 °CPipe MountingBrass0,3 bar--8,1 m3/hour2/2 Way-Water, Neutral Liquids20 mmNormally ClosedNBR---Pilot Operated---10 °C3/4" G135 l/min16 bar AC/DC
E321G3606
Backordered
POR
Fluid and Climate Controls Europe120 °CPipe MountingBrass0,3 bar--8,1 m3/hour2/2 Way-Water, Neutral Liquids20 mmNormally ClosedFKM---Pilot Operated---10 °C3/4" G135 l/min16 bar AC/DC
E321G3606-2995-481865C2
Backordered
POR
Fluid and Climate Controls Europe100 °CPipe MountingBrass0,3 bar9 W-40+50 °C8,1 m3/hour2/2 WayF 155 °CWater, Neutral Liquids20 mmNormally ClosedFKM-24V DCCE - VDE - EACPilot Operated2 P + E plug according to EN 175301-803 type A--10 °C3/4" G135 l/min16 bar
E321G3610
Backordered
POR
Fluid and Climate Controls Europe100 °CPipe MountingBrass0,3 bar--8,1 m3/hour2/2 Way-Water, Neutral Liquids20 mmNormally ClosedNBRManual Override - Closure Speed Control--Pilot Operated---10 °C3/4" G135 l/min16 bar AC/DC
E321G3610-2995-481865A5
Backordered
POR
Fluid and Climate Controls Europe100 °CPipe MountingBrass0,3 bar8 W-40+50 °C8,1 m3/hour2/2 WayF 155 °CWater, Neutral Liquids20 mmNormally ClosedNBRManual Override - Closure Speed Control110V 50HzCE - VDE - EACPilot Operated2 P + E plug according to EN 175301-803 type A--10 °C3/4" G135 l/min16 bar
E321G3610-2995-481865C2
Backordered
POR
Fluid and Climate Controls Europe100 °CPipe MountingBrass0,3 bar9 W-40+50 °C8,1 m3/hour2/2 WayF 155 °CWater, Neutral Liquids20 mmNormally ClosedNBRManual Override - Closure Speed Control24V DCCE - VDE - EACPilot Operated2 P + E plug according to EN 175301-803 type A--10 °C3/4" G135 l/min16 bar
E321G36-2995-481865C2
Backordered
POR
Fluid and Climate Controls Europe100 °CPipe MountingBrass0,3 bar9 W-40+50 °C8,1 m3/hour2/2 WayF 155 °CWater, Neutral Liquids20 mmNormally ClosedNBR-24V DCCE - VDE - EACPilot Operated2 P + E plug according to EN 175301-803 type A--10 °C3/4" G135 l/min16 bar
E321G37
Backordered
POR
Fluid and Climate Controls Europe100 °CPipe MountingBrass0,3 bar--10,8 m3/hour2/2 Way-Air, Inert Gases, Liquids25 mmNormally ClosedNBR---Pilot Operated---10 °C1" G180 l/min16 bar AC/DC
E321G3706
Backordered
POR
Fluid and Climate Controls Europe120 °CPipe MountingBrass0,3 bar--10,8 m3/hour2/2 Way-Air, Inert Gases, Liquids25 mmNormally ClosedFKM---Pilot Operated---10 °C1" G180 l/min16 bar AC/DC
E321G3706-2995-481865C2
Backordered
POR
Fluid and Climate Controls Europe100 °CPipe MountingBrass0,3 bar9 W-40+50 °C10,8 m3/hour2/2 WayF 155 °CAir, Inert Gases, Liquids25 mmNormally ClosedFKM-24V DCCE - VDE - EACPilot Operated2 P + E plug according to EN 175301-803 type A--10 °C1" G180 l/min16 bar
E321G3710
Backordered
POR
Fluid and Climate Controls Europe100 °CPipe MountingBrass0,3 bar--10,8 m3/hour2/2 Way-Water, Neutral Liquids25 mmNormally ClosedNBRManual Override - Closure Speed Control--Pilot Operated---10 °C1" G180 l/min16 bar AC/DC
E321G3710-2995-4818653D
Backordered
POR
Fluid and Climate Controls Europe100 °CPipe MountingBrass0,3 bar8 W-40+50 °C10,8 m3/hour2/2 WayF 155 °CWater, Neutral Liquids25 mmNormally ClosedNBRManual Override - Closure Speed Control220-230V 50HzCE - VDE - EACPilot Operated2 P + E plug according to EN 175301-803 type A--10 °C1" G180 l/min16 bar
E321G3710-2995-481865C2
Backordered
POR
Fluid and Climate Controls Europe100 °CPipe MountingBrass0,3 bar9 W-40+50 °C10,8 m3/hour2/2 WayF 155 °CWater, Neutral Liquids25 mmNormally ClosedNBRManual Override - Closure Speed Control24V DCCE - VDE - EACPilot Operated2 P + E plug according to EN 175301-803 type A--10 °C1" G180 l/min16 bar
E321G3710-2995-483510S6
Backordered
POR
Fluid and Climate Controls Europe100 °CPipe MountingBrass0,3 bar9 W-40+50 °C10,8 m3/hour2/2 WayF 155 °CWater, Neutral Liquids25 mmNormally ClosedNBRManual Override - Closure Speed Control220-240V 50Hz - 240V 60HzCE - VDE - EACPilot Operated2 P + E plug according to EN 175301-803 type A--10 °C1" G180 l/min16 bar
E321G37-2995-4818653D
Backordered
POR
Fluid and Climate Controls Europe100 °CPipe MountingBrass0,3 bar8 W-40+50 °C10,8 m3/hour2/2 WayF 155 °CAir, Inert Gases, Liquids25 mmNormally ClosedNBR-220-230V 50HzCE - VDE - EACPilot Operated2 P + E plug according to EN 175301-803 type A--10 °C1" G180 l/min16 bar
E321G37-2995-481865A2
Backordered
POR
Fluid and Climate Controls Europe100 °CPipe MountingBrass0,3 bar8 W-40+50 °C10,8 m3/hour2/2 WayF 155 °CAir, Inert Gases, Liquids25 mmNormally ClosedNBR-24V 50HzCE - VDE - EACPilot Operated2 P + E plug according to EN 175301-803 type A--10 °C1" G180 l/min16 bar
E321G37-2995-481865C2
Backordered
POR
Fluid and Climate Controls Europe100 °CPipe MountingBrass0,3 bar9 W-40+50 °C10,8 m3/hour2/2 WayF 155 °CAir, Inert Gases, Liquids25 mmNormally ClosedNBR-24V DCCE - VDE - EACPilot Operated2 P + E plug according to EN 175301-803 type A--10 °C1" G180 l/min16 bar
E321G38
Backordered
POR
Fluid and Climate Controls Europe100 °CPipe MountingBrass0,3 bar--16,2 m3/hour2/2 Way-Air, Inert Gases, Liquids28 mmNormally ClosedNBR---Pilot Operated---10 °C1 1/4" G270 l/min16 bar AC/DC
E321G3806-2995-481865C2
Backordered
POR
Fluid and Climate Controls Europe100 °CPipe MountingBrass0,3 bar9 W-40+50 °C16,2 m3/hour2/2 WayF 155 °CAir, Inert Gases, Liquids28 mmNormally ClosedFKM-24V DCCE - VDE - EACPilot Operated2 P + E plug according to EN 175301-803 type A--10 °C1 1/4" G270 l/min16 bar

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains