*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Action | SKU | Availability | Price | Function | Port Size | Installation | Orifice Size | Body Material | Configuration | Input Voltage | Seal Material | Actuation Type | Power Consumption | Division | Main Flow Coefficient | Maximum Fluid Temperature | Preventive Maintenance Kit | Maximum Ambient Temperature | Maximum Pressure Differential | Minimum Pressure Differential | Specifications Met | Coil Specifications Met | Exhaust Flow Coefficient | Voltage | Function | Coil Type | Body Material | Configuration | Seal Material | Port Size (inch) | Orifice Size (inch) | Minimum Pressure Differential (psi) | Maximum Operating Pressure Differential (psig) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
20CC041V7 | Backordered | POR | 2-Way | NPT 1/4 inch | IOM7220 | 9/32 inch | Stainless Steel 303 | All Ports in Body | Pressure Vessel Only (AC or DC Voltage) | FKM | Direct Acting | 10 W | Fluid Control Division | 1.06 Cv | 185 °F | 7R003 | 150 °F | 40 psig (AC) | 0 psi | - | Requires G7 Series Coil Kit | n/a | Pressure Vessel Only (AC or DC Voltage) | 2-Way | Requires G7 Series Coil Kit | 303 Stainless Steel | Normally Closed | FKM | 1/4 NPT | 9/32 | 0 | 40 (AC) / 15 (DC) | |
20CC041V7B7A | Backordered | POR | 2-Way | NPT 1/4 inch | IOM7220 | 9/32 inch | Stainless Steel 303 | All Ports in Body | 12.0 VDC | FKM | Direct Acting | 10 W | Fluid Control Division | 1.06 Cv | 185 °F | 7R003 | 150 °F | 15 psig | 0 psi | CURus Safety Shutoff | IP69 | n/a | 12 VDC | 2-Way | Leads-only (Incl. Ground Lead) | 303 Stainless Steel | Normally Closed | FKM | 1/4 NPT | 9/32 | 0 | 15 | |
20CC041V7C7B | 9 in stock | POR | 2-Way | NPT 1/4 inch | IOM7220 | 9/32 inch | Stainless Steel 303 | All Ports in Body | 24.0 VDC | FKM | Direct Acting | 10 W | Fluid Control Division | 1.06 Cv | 185 °F | 7R003 | 150 °F | 15 psig | 0 psi | CULus Safety Shutoff | IP69 | n/a | 24 VDC | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | 303 Stainless Steel | Normally Closed | FKM | 1/4 NPT | 9/32 | 0 | 15 | |
20CC041V7C7F | Backordered | POR | 2-Way | NPT 1/4 inch | IOM7220 | 9/32 inch | Stainless Steel 303 | All Ports in Body | 110/50 VAC | FKM | Direct Acting | 10 W | Fluid Control Division | 1.06 Cv | 185 °F | 7R003 | 150 °F | 40 psig | 0 psi | CULus Safety Shutoff | IP69 | n/a | 120/60, 110/50 | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | 303 Stainless Steel | Normally Closed | FKM | 1/4 NPT | 9/32 | 0 | 40 | |
20CC041V7C7G | 45 in stock | POR | 2-Way | NPT 1/4 inch | IOM7220 | 9/32 inch | Stainless Steel 303 | Normally Closed (NC) | 240/60 | FKM | Direct Acting | 10 W | Fluid Control Division | 1.06 Cv | 185 °F | 7R003 | 150 °F | 40 psig | 0 psi | CULus Safety Shutoff | IP69 | n/a | 240/60, 220/50 | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | 303 Stainless Steel | Normally Closed | FKM | 1/4 NPT | 9/32 | 0 | 40 | |
20CC041V7D7B | 3 in stock | POR | 2-Way | NPT 1/4 inch | IOM7220 | 9/32 inch | Stainless Steel 303 | Normally Closed (NC) | 24.0 VDC | FKM | Direct Acting | 10 W | Fluid Control Division | 1.06 Cv | 185 °F | 7R003 | 150 °F | 15 psig | 0 psi | CURus Safety Shutoff | IP65 | n/a | 24 VDC | 2-Way | DIN 43650A / ISO 4400 | 303 Stainless Steel | Normally Closed | FKM | 1/4 NPT | 9/32 | 0 | 15 | |
20CC04EP7 | Backordered | POR | 2-Way | NPT 1/4 inch | IOM7220 | 3/64 inch | Stainless Steel 303 | All Ports in Body | Pressure Vessel Only (AC or DC Voltage) | UR (Urethane) | Direct Acting | 10 W | Fluid Control Division | 0.05 Cv | 140 °F | 7R001 | 150 °F | 2200 psig | 0 psi | - | Requires G7 Series Coil Kit | n/a | Pressure Vessel Only (AC or DC Voltage) | 2-Way | Requires G7 Series Coil Kit | 303 Stainless Steel | Normally Closed | UR (Urethane) | 1/4 NPT | 3/64 | 0 | 2200 | |
20CC04EP7B7B | Backordered | POR | 2-Way | NPT 1/4 inch | IOM7220 | 3/64 inch | Stainless Steel 303 | All Ports in Body | 24.0 VDC | UR (Urethane) | Direct Acting | 10 W | Fluid Control Division | 0.05 Cv | 140 °F | 7R001 | 150 °F | 2200 psig | 0 psi | CURus General Purpose | IP69 | n/a | 24 VDC | 2-Way | Leads-only (Incl. Ground Lead) | 303 Stainless Steel | Normally Closed | UR (Urethane) | 1/4 NPT | 3/64 | 0 | 2200 | |
20CC04EP7C7B | Backordered | POR | 2-Way | NPT 1/4 inch | IOM7220 | 3/64 inch | Stainless Steel 303 | Normally Closed (NC) | 24.0 VDC | UR (Urethane) | Direct Acting | 10 W | Fluid Control Division | 0.05 Cv | 140 °F | 7R001 | 150 °F | 2200 psig | 0 psi | CULus General Purpose | IP69 | n/a | 24 VDC | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | 303 Stainless Steel | Normally Closed | UR (Urethane) | 1/4 NPT | 3/64 | 0 | 2200 | |
20CC04EP7C7E | Backordered | POR | 2-Way | NPT 1/4 inch | IOM7220 | 3/64 inch | Stainless Steel 303 | All Ports in Body | 24/60 | UR (Urethane) | Direct Acting | 10 W | Fluid Control Division | 0.05 Cv | 140 °F | 7R001 | 150 °F | 2200 psig | 0 psi | CULus General Purpose | IP69 | n/a | 24/60 | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | 303 Stainless Steel | Normally Closed | UR (Urethane) | 1/4 NPT | 3/64 | 0 | 2200 | |
20CC04EP7C7F | Backordered | POR | 2-Way | NPT 1/4 inch | IOM7220 | 3/64 inch | Stainless Steel 303 | Normally Closed (NC) | 120/60 VAC | UR (Urethane) | Direct Acting | 10 W | Fluid Control Division | 0.05 Cv | 140 °F | 7R001 | 150 °F | 2200 psig | 0 psi | CULus General Purpose | IP69 | n/a | 120/60, 110/50 | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | 303 Stainless Steel | Normally Closed | UR (Urethane) | 1/4 NPT | 3/64 | 0 | 2200 | |
20CC04EP7D7B | 21 in stock | POR | 2-Way | NPT 1/4 inch | IOM7220 | 3/64 inch | Stainless Steel 303 | Normally Closed (NC) | 24.0 VDC | UR (Urethane) | Direct Acting | 10 W | Fluid Control Division | 0.05 Cv | 140 °F | 7R001 | 150 °F | 2200 psig | 0 psi | CURus General Purpose | IP65 | n/a | 24 VDC | 2-Way | DIN 43650A / ISO 4400 | 303 Stainless Steel | Normally Closed | UR (Urethane) | 1/4 NPT | 3/64 | 0 | 2200 | |
20CC04GP7 | 2 in stock | POR | 2-Way | NPT 1/4 inch | IOM7220 | 1/16 inch | Stainless Steel 303 | Normally Closed (NC) | Pressure Vessel Only (AC or DC Voltage) | UR (Urethane) | Direct Acting | 10 W | Fluid Control Division | 0.1 Cv | 140 °F | 7R001 | 150 °F | 1400.0 psig (AC) | 0 psi | - | Requires G7 Series Coil Kit | n/a | Pressure Vessel Only (AC or DC Voltage) | 2-Way | Requires G7 Series Coil Kit | 303 Stainless Steel | Normally Closed | UR (Urethane) | 1/4 NPT | 1/16 | 0 | 1400 (AC) / 1250 (DC) | |
20CC04GP7C7B | Backordered | POR | 2-Way | NPT 1/4 inch | IOM7220 | 1/16 inch | Stainless Steel 303 | All Ports in Body | 24.0 VDC | UR (Urethane) | Direct Acting | 10 W | Fluid Control Division | 0.1 Cv | 140 °F | 7R001 | 150 °F | 1250 psig | 0 psi | CULus General Purpose | IP69 | n/a | 24 VDC | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | 303 Stainless Steel | Normally Closed | UR (Urethane) | 1/4 NPT | 1/16 | 0 | 1250 | |
20CC04GP7C7F | 1 in stock | POR | 2-Way | NPT 1/4 inch | IOM7220 | 1/16 inch | Stainless Steel 303 | All Ports in Body | 110/50 VAC | UR (Urethane) | Direct Acting | 10 W | Fluid Control Division | 0.1 Cv | 140 °F | 7R001 | 150 °F | 1400 psig | 0 psi | CULus General Purpose | IP69 | n/a | 120/60, 110/50 | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | 303 Stainless Steel | Normally Closed | UR (Urethane) | 1/4 NPT | 1/16 | 0 | 1400 | |
20CC04GP7D7B | Backordered | POR | 2-Way | NPT 1/4 inch | IOM7220 | 1/16 inch | Stainless Steel 303 | Normally Closed (NC) | 24.0 VDC | UR (Urethane) | Direct Acting | 10 W | Fluid Control Division | 0.1 Cv | 140 °F | 7R001 | 150 °F | 1250 psig | 0 psi | CURus General Purpose | IP65 | n/a | 24 VDC | 2-Way | DIN 43650A / ISO 4400 | 303 Stainless Steel | Normally Closed | UR (Urethane) | 1/4 NPT | 1/16 | 0 | 1250 | |
20CC04GV7 | Backordered | POR | 2-Way | NPT 1/4 inch | IOM7220 | 1/16 inch | Stainless Steel 303 | All Ports in Body | Pressure Vessel Only (AC or DC Voltage) | FKM | Direct Acting | 10 W | Fluid Control Division | 0.1 Cv | 185 °F | 7R003 | 150 °F | 750 psig | 0 psi | - | Requires G7 Series Coil Kit | n/a | Pressure Vessel Only (AC or DC Voltage) | 2-Way | Requires G7 Series Coil Kit | 303 Stainless Steel | Normally Closed | FKM | 1/4 NPT | 1/16 | 0 | 750 | |
20CC04GV7B7A | Backordered | POR | 2-Way | NPT 1/4 inch | IOM7220 | 1/16 inch | Stainless Steel 303 | Normally Closed (NC) | 12.0 VDC | FKM | Direct Acting | 10 W | Fluid Control Division | 0.1 Cv | 185 °F | 7R003 | 150 °F | 750 psig | 0 psi | CURus Safety Shutoff | IP69 | n/a | 12 VDC | 2-Way | Leads-only (Incl. Ground Lead) | 303 Stainless Steel | Normally Closed | FKM | 1/4 NPT | 1/16 | 0 | 750 | |
20CC04GV7B7B | Backordered | POR | 2-Way | NPT 1/4 inch | IOM7220 | 1/16 inch | Stainless Steel 303 | Normally Closed (NC) | 24.0 VDC | FKM | Direct Acting | 10 W | Fluid Control Division | 0.1 Cv | 185 °F | 7R003 | 150 °F | 750 psig | 0 psi | CURus Safety Shutoff | IP69 | n/a | 24 VDC | 2-Way | Leads-only (Incl. Ground Lead) | 303 Stainless Steel | Normally Closed | FKM | 1/4 NPT | 1/16 | 0 | 750 | |
20CC04GV7B7F | Backordered | POR | 2-Way | NPT 1/4 inch | IOM7220 | 1/16 inch | Stainless Steel 303 | Normally Closed (NC) | 120/60 VAC | FKM | Direct Acting | 10 W | Fluid Control Division | 0.1 Cv | 185 °F | 7R003 | 150 °F | 750 psig | 0 psi | CURus Safety Shutoff | IP69 | n/a | 120/60, 110/50 | 2-Way | Leads-only (Incl. Ground Lead) | 303 Stainless Steel | Normally Closed | FKM | 1/4 NPT | 1/16 | 0 | 750 |