• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Body Material
  • Coil Specifications Met
  • Coil Type
  • Configuration
  • Configuration
  • Division
  • Exhaust Flow Coefficient
  • Function
More Filters...

G7 SERIES Solenoid Valves

Picture for category G7 SERIES Solenoid Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker Gold Ring™ and Skinner® valves have evolved.
The next generation of 2/2 and 3/2 solenoid valves delivers the confidence to get the job done in the most demanding applications.
High performance, Express Ship Program-eligibility, and a host of new and innovative features make doing business easier than ever before.
Ensuring high performance and an optimized total cost of ownership, Parker continues to focus on Engineering Your Success.

Features/ Benefits:
• Engineered for Long Life (up to 20 million cycles)
• Industry-Leading Pressure, Flow, and Temperature ratings - even in DC voltages
• IP69-rated Solenoid Coils
• Corrosion-Resistant Construction
• 24-Hour Express Ship Program
• Durable Laser-Marked Identification
• Innovative Parker Tracking System (PTS)

Markets:
• Commercial Equipment
• Food & Beverage
• Industrial Automation
• Oil & Gas
• Process Control
• Transportation

Applications
• Instrumentation Equipment
• Analyzers and Diagnostic Equipment
• Medical and Dental Equipment
• Portable Welding Equipment
• Spraying Equipment
• Lubrication Equipment
• Commercial and Industrial Plumbing
• Oil Burners
• Fuel Shut Off
• Textile and Dry Cleaning Equipment
• Irrigation Equipment
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceFunctionBody MaterialSeal MaterialSpecifications MetDivisionPort SizeInstallationOrifice SizeConfigurationInput VoltageActuation TypePower ConsumptionMain Flow CoefficientCoil Specifications MetExhaust Flow CoefficientMaximum Fluid TemperaturePreventive Maintenance KitMaximum Ambient TemperatureMaximum Pressure DifferentialMinimum Pressure DifferentialVoltageFunctionCoil TypeBody MaterialConfigurationSeal MaterialPort Size (inch)Orifice Size (inch)Minimum Pressure Differential (psi)Maximum Operating Pressure Differential (psig)
20LC041N7D7F
Backordered
POR
2-WayLead-Free BrassNBRCURus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72209/32 inchAll Ports in Body110/50 VACDirect Acting10 W1.06 CvIP65n/a185 °F7R004150 °F40 psig0 psi120/60, 110/502-WayDIN 43650A / ISO 4400Lead-Free BrassNormally ClosedNBR1/4 NPT9/32040
20LC04GN7
Backordered
POR
2-WayLead-Free BrassNBR-Fluid Control DivisionNPT 1/4 inchIOM72201/16 inchNormally Closed (NC)Pressure Vessel Only (AC or DC Voltage)Direct Acting10 W0.1 CvRequires G7 Series Coil Kitn/a185 °F7R004150 °F750 psig0 psiPressure Vessel Only (AC or DC Voltage)2-WayRequires G7 Series Coil KitLead-Free BrassNormally ClosedNBR1/4 NPT1/160750
20LC04GN7C7B
Backordered
POR
2-WayLead-Free BrassNBRCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72201/16 inchNormally Closed (NC)24.0 VDCDirect Acting10 W0.1 CvIP69n/a185 °F7R004150 °F750 psig0 psi24 VDC2-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedNBR1/4 NPT1/160750
20LC04GN7C7F
Backordered
POR
2-WayLead-Free BrassNBRCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72201/16 inchAll Ports in Body110/50 VACDirect Acting10 W0.1 CvIP69n/a185 °F7R004150 °F750 psig0 psi120/60, 110/502-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedNBR1/4 NPT1/160750
20LC04LN7
Backordered
POR
2-WayLead-Free BrassNBR-Fluid Control DivisionNPT 1/4 inchIOM72203/32 inchAll Ports in BodyPressure Vessel Only (AC or DC Voltage)Direct Acting10 W0.18 CvRequires G7 Series Coil Kitn/a185 °F7R004150 °F550 psig (AC)0 psiPressure Vessel Only (AC or DC Voltage)2-WayRequires G7 Series Coil KitLead-Free BrassNormally ClosedNBR1/4 NPT3/320550 (AC) / 520 (DC)
20LC04LN7C7B
Backordered
POR
2-WayLead-Free BrassNBRCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72203/32 inchNormally Closed (NC)24.0 VDCDirect Acting10 W0.18 CvIP69n/a185 °F7R004150 °F520 psig0 psi24 VDC2-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedNBR1/4 NPT3/320520
20LC04LN7C7F
Backordered
POR
2-WayLead-Free BrassNBRCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72203/32 inchAll Ports in Body110/50 VACDirect Acting10 W0.18 CvIP69n/a185 °F7R004150 °F550 psig0 psi120/60, 110/502-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedNBR1/4 NPT3/320550
20LC04LN7D7B
Backordered
POR
2-WayLead-Free BrassNBRCURus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72203/32 inchAll Ports in Body24.0 VDCDirect Acting10 W0.18 CvIP65n/a185 °F7R004150 °F520 psig0 psi24 VDC2-WayDIN 43650A / ISO 4400Lead-Free BrassNormally ClosedNBR1/4 NPT3/320520
20LC04LN7D7F
Backordered
POR
2-WayLead-Free BrassNBRCURus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72203/32 inchAll Ports in Body110/50 VACDirect Acting10 W0.18 CvIP65n/a185 °F7R004150 °F550 psig0 psi120/60, 110/502-WayDIN 43650A / ISO 4400Lead-Free BrassNormally ClosedNBR1/4 NPT3/320550
20LC04PN7
Backordered
POR
2-WayLead-Free BrassNBR-Fluid Control DivisionNPT 1/4 inchIOM72201/8 inchNormally Closed (NC)Pressure Vessel Only (AC or DC Voltage)Direct Acting10 W0.29 CvRequires G7 Series Coil Kitn/a185 °F7R004150 °F375 psig (AC)0 psiPressure Vessel Only (AC or DC Voltage)2-WayRequires G7 Series Coil KitLead-Free BrassNormally ClosedNBR1/4 NPT1/80375 (AC) / 165 (DC)
20LC04PN7C7B
Backordered
POR
2-WayLead-Free BrassNBRCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72201/8 inchAll Ports in Body24.0 VDCDirect Acting10 W0.29 CvIP69n/a185 °F7R004150 °F165 psig0 psi24 VDC2-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedNBR1/4 NPT1/80165
20LC04PN7C7F
Backordered
POR
2-WayLead-Free BrassNBRCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72201/8 inchAll Ports in Body110/50 VACDirect Acting10 W0.29 CvIP69n/a185 °F7R004150 °F375 psig0 psi120/60, 110/502-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedNBR1/4 NPT1/80375
20LC04PN7D7B
Backordered
POR
2-WayLead-Free BrassNBRCURus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72201/8 inchAll Ports in Body24.0 VDCDirect Acting10 W0.29 CvNEMA 4n/a185 °F7R004150 °F165 psig0 psi24 VDC2-WayDIN 43650A / ISO 4400Lead-Free BrassNormally ClosedNBR1/4 NPT1/80165
20LC04PV7
Backordered
POR
2-WayLead-Free BrassFKM-Fluid Control DivisionNPT 1/4 inchIOM72201/8 inchAll Ports in BodyPressure Vessel Only (AC or DC Voltage)Direct Acting10 W0.29 CvRequires G7 Series Coil Kitn/a185 °F7R003150 °F375 psig (AC)0 psiPressure Vessel Only (AC or DC Voltage)2-WayRequires G7 Series Coil KitLead-Free BrassNormally ClosedFKM1/4 NPT1/80375 (AC) / 165 (DC)
20LC04PV7C7B
Backordered
POR
2-WayLead-Free BrassFKMCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72201/8 inchAll Ports in Body24.0 VDCDirect Acting10 W0.29 CvIP69n/a185 °F7R003150 °F165 psig0 psi24 VDC2-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedFKM1/4 NPT1/80165
20LC04PV7C7F
Backordered
POR
2-WayLead-Free BrassFKMCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72201/8 inchNormally Closed (NC)120/60 VACDirect Acting10 W0.29 CvIP69n/a185 °F7R003150 °F375 psig0 psi120/60, 110/502-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedFKM1/4 NPT1/80375
20LC04PV7D7B
Backordered
POR
2-WayLead-Free BrassFKMCURus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72201/8 inchAll Ports in Body24.0 VDCDirect Acting10 W0.29 CvNEMA 4n/a185 °F7R003150 °F165 psig0 psi24 VDC2-WayDIN 43650A / ISO 4400Lead-Free BrassNormally ClosedFKM1/4 NPT1/80165
20LC04QN7
Backordered
POR
2-WayLead-Free BrassNBR-Fluid Control DivisionNPT 1/4 inchIOM72205/32 inchAll Ports in BodyPressure Vessel Only (AC or DC Voltage)Direct Acting10 W0.43 CvRequires G7 Series Coil Kitn/a185 °F7R004150 °F230 psig (AC)0 psiPressure Vessel Only (AC or DC Voltage)2-WayRequires G7 Series Coil KitLead-Free BrassNormally ClosedNBR1/4 NPT5/320230 (AC) / 85 (DC)
20LC04QN7C7A
Backordered
POR
2-WayLead-Free BrassNBRCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72205/32 inchNormally Closed (NC)12.0 VDCDirect Acting10 W0.43 CvIP69n/a185 °F7R004150 °F85 psig0 psi12 VDC2-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedNBR1/4 NPT5/32085
20LC04QN7C7B
Backordered
POR
2-WayLead-Free BrassNBRCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72205/32 inchAll Ports in Body24.0 VDCDirect Acting10 W0.43 CvIP69n/a185 °F7R004150 °F85 psig0 psi24 VDC2-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedNBR1/4 NPT5/32085

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains