• Availability & Price
  • Search SKU
Filter by attributes
  • Additional Options
  • Additional Protection Included
  • Allowable rotational torque
  • Contact Rating
  • Division
  • Length
  • Maximum Operating Voltage
  • Media
  • Operating Temperature
  • Power Consumption
More Filters...

Level Switches- level measurement (JB, JC7, JD, JF, JRS Series)

Picture for category Level Switches- level measurement (JB, JC7, JD, JF, JRS Series)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

A level switch is a device used to detect the level of substances such as liquid, chemical solvent, powders, lumps within tanks, silos, and hoppers. In addition, a level switch prevents overfilling of tanks and silos and ensures tanks do not run too low, possibly interrupting production.

JB Series - Features :
• A compact type product that can be easily maintained and repaired in small spaces
• Optimum for controlling powders and fine particles such as flour, wheat, sugar, and plastic materials
• Highly sensitive with buil-in springs that can be adjusted to four levels

JC7 Series - Features :
• Detection of the heights of stored goods
• Made with alumimum cases, these types can be installed and used outdorrs
• Customizatin with a various length of shaft

JD Series - Features :
• Easy handling and wiring
• Since the structure is simple, troubles occur rarely and maintenance is easy

JRS Series - Features :
• Detection balls and detection rods are completely enclosed and thus the products are not affected by pressure, vacuum, or gases
• The lead switch is enclosed in glass tube containing inert gas and thus the products operate safely in combustible gases

JF Series - Features :
• Used in small spaces and low flow rate tanks
• Applicable to water cooler/heater, coffee vending machines, medical appliances
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceDivisionAllowable rotational torqueProduct TypeMediaOperating TemperatureContact RatingRated SpeedPower ConsumptionMaximum Operating VoltageLengthAdditional OptionsAdditional Protection IncludedSeries
JC7-SL-AC110V 220MM
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 110V (50Hz)220 mmPropeller - Half wingNonJC7-SL
JC7-SL-AC110V 220MMP
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 110V (50Hz)220 mmPropeller - Half wingProtection Tube AttachedJC7-SL
JC7-SL-AC110V 2500MM
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 110V (50Hz)2500 mmPropeller - Half wingNonJC7-SL
JC7-SL-AC110V 250MM
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 110V (50Hz)250 mmPropeller - Half wingNonJC7-SL
JC7-SL-AC110V 250MMP
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 110V (50Hz)250 mmPropeller - Half wingProtection Tube AttachedJC7-SL
JC7-SL-AC110V 3000MM
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 110V (50Hz)3000 mmPropeller - Half wingNonJC7-SL
JC7-SL-AC110V 300MM
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 110V (50Hz)300 mmPropeller - Half wingNonJC7-SL
JC7-SL-AC110V 300MMP
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 110V (50Hz)300 mmPropeller - Half wingProtection Tube AttachedJC7-SL
JC7-SL-AC110V 350MM
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 110V (50Hz)350 mmPropeller - Half wingNonJC7-SL
JC7-SL-AC110V 350MMP
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 110V (50Hz)350 mmPropeller - Half wingProtection Tube AttachedJC7-SL
JC7-SL-AC110V 400MM
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 110V (50Hz)400 mmPropeller - Half wingNonJC7-SL
JC7-SL-AC110V 450MM
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 110V (50Hz)450 mmPropeller - Half wingNonJC7-SL
JC7-SL-AC110V 500MM
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 110V (50Hz)500 mmPropeller - Half wingNonJC7-SL
JC7-SL-AC110V 570MM
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 110V (50Hz)570 mmPropeller - Half wingNonJC7-SL
JC7-SL-AC110V 600MM
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 110V (50Hz)600 mmPropeller - Half wingNonJC7-SL
JC7-SL-AC110V 700MM
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 110V (50Hz)700 mmPropeller - Half wingNonJC7-SL
JC7-SL-AC110V 800MM
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 110V (50Hz)800 mmPropeller - Half wingNonJC7-SL
JC7-SL-AC220V
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropellerLumps0 to 60 (0 to 120 Optional) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 220V (60Hz)NAPropeller - Half wingNAJC7-SL
JC7-SL-AC220V 1000MM
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 220V (60Hz)1000 mmPropeller - Half wingNonJC7-SL
JC7-SL-AC220V 110MM
Backordered
POR
Motion Systems Division Korea500 to 1000 g/cmPropeller - Half wingLumps0 to 60 STANDARD (0 to 120 HEAT-RESISTANT) °C3 A AC250V6 RPM3 (When blad rotates) V/AAC 220V (60Hz)110 mmPropeller - Half wingNonJC7-SL

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains