Product Overview

The Parker LoadTECH® product line is comprised of extended surface rigid cell filters. All filters utilize proprietary E-Pleat® media technology, which molds filtration media into a series of pre-formed channels that direct the air smoothly through the filter, allowing for even loading and complete media utilization.
The compact 4-inch design offers the same filtration performance as a 12-inch filter, but in a much smaller envelope, resulting in simplified handling, plus reduced storage space requirements and shipping costs. The 12-inch filter performance rivals the dust holding capacity of commercial 4-V filters in the HVAC market and are of tremendous value in applications where energy and total cost of ownership are priority.
The high-impact polystyrene (HIPS) frame resists cracking and is not affected by corrosion. The media resists tearing, damage, moisture and microbial growth. The filter is also completely incinerable, which minimizes waste disposal costs.
LoadTECH® filters are available in MERV 14, MERV 11 and MERV 8 efficiency ratings per ASHRAE Standard 52.2-2017. MERV 14 and MERV 11 efficiencies are available in box and single header construction in both 4-inch and 12-inch depths. MERV 8 is available in 4-inch box frame construction. These filters are fully incinerable and ideal for use in variable air volume (VAV) systems.

Markets

• Commercial and Industrial HVAC
• Process Air Filtration

Applications

• Hotels and entertainment complexes
• Food processing
• Microelectronics manufacturing
• Data centers
• Commercial office buildings
• Schools and universities
• Clean manufacturing facilities
• Hospitals and healthcare facilities
• Government institutions
• Industrial manufacturing

Benefits


• Proprietary E-Pleat® media technology efficiently directs air flow through the filter
• Offers longer service life and fewer filter change-outs with higher dust holding capacity
• Energy savings – Low pressure drop offers reduced energy use
• Completely incinerable with high impact polystyrene (HIPS) frame
• MERV 14 meets the efficiency requirements to earn points toward LEED green building certification

Features


• Filtration efficiency rating: MERV 14, MERV 11 and MERV 8 per ASHRAE Standard 52.2-2017
• Depth (in.): 4, 12
• Construction: Available in box and single header
• Materials of construction: high-impact polystyrene (HIPS) frame, synthetic media with embossed design, adhesive beads bond pleats   into rigid pack
• Maximum operating temperature: 170 °F (77 °C)
• Rated face velocity: 500 FPM
• Recommended final resistance: 1.50” W.G.
• Classified per UL Standard 900 for Flammability

Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceFilter MaterialFilter AreaBrandDivisionWeightRated Air VelocityMaterials of ConstructionActual DepthIndustryActual HeightFor Fluid TypeFlow RateTechnologyPackage QuantityActual WidthProduct TypeModel NumberApplicationDivisionSpecifications MetMaximum Operating TemperatureMedia ColorProduct StyleMicron RatingInitial ResistanceNominal Filter SizeFilter Efficiency RatingAir Filter Frame/Header TypeDimensional Weight
1135750
Backordered
POR
Synthetic60 ft2PARKERHVAC Filtration Division3.0 lbs.500 ft/min24 Gauge Galvanized Steel Frame11.5 inchHVAC and Refrigeration23.375 inchAir1000 CFMFiltration111.375 inchExtended Surface Rigid Cell FiltersPLT12-M14-03-NH-MCAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FGoldHVAC Frame System≥ 90% : 1.0 to 3.0 micron0.29 in wg12X24X12 (WxHxD)MERV 1412-Inch Metal Cell, no Header
1135751
Backordered
POR
Synthetic122 ft2PARKERHVAC Filtration Division21.0 lbs.500 ft/min24 Gauge Galvanized Steel Frame11.5 inchHVAC and Refrigeration23.375 inchAir2000 CFMFiltration123.375 inchExtended Surface Rigid Cell FiltersPLT12-M14-04-NH-MCAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FGoldHVAC Frame System≥ 90% : 1.0 to 3.0 micron0.29 in wg24X24X12 (WxHxD)MERV 1412-Inch Metal Cell, no Header
1135752
Backordered
POR
Synthetic103 ft2PARKERHVAC Filtration Division21.0 lbs.500 ft/min24 Gauge Galvanized Steel Frame11.5 inchHVAC and Refrigeration23.375 inchAir1650 CFMFiltration119.375 inchExtended Surface Rigid Cell FiltersPLT12-M14-15-NH-MCAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FGoldHVAC Frame System≥ 90% : 1.0 to 3.0 micron0.29 in wg20X24X12 (WxHxD)MERV 1412-Inch Metal Cell, no Header
1135799
Backordered
POR
Synthetic46 ft2PARKERHVAC Filtration Division8.0 lbs.500 ft/minHigh-Impact Plastic Frame Panels11.5 inchHVAC and Refrigeration23.375 inchAir1000 CFMFiltration211.375 inchExtended Surface Rigid Cell FiltersPLT12-M14-03-PH-DAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FGoldHVAC Frame System≥ 90% : 1.0 to 3.0 micron0.38 in wg12X24X12 (WxHxD)MERV 1412-Inch Plastic Box, Single Header, Downstream Gasket
1135800
Backordered
POR
Synthetic46 ft2PARKERHVAC Filtration Division8.0 lbs.500 ft/minHigh-Impact Plastic Frame Panels11.5 inchHVAC and Refrigeration23.375 inchAir1000 CFMFiltration211.375 inchExtended Surface Rigid Cell FiltersPLT12-M14-03-PH-SAAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FGoldHVAC Frame System≥ 90% : 1.0 to 3.0 micron0.38 in wg12X24X12 (WxHxD)MERV 1412-Inch Plastic Box, Single Header, Side Access Gasket
1135801
Backordered
POR
Synthetic105 ft2PARKERHVAC Filtration Division12.0 lbs.500 ft/minHigh-Impact Plastic Frame Panels11.5 inchHVAC and Refrigeration23.375 inchAir2000 CFMFiltration123.375 inchExtended Surface Rigid Cell FiltersPLT12-M14-04-PH-DAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FGoldHVAC Frame System≥ 90% : 1.0 to 3.0 micron0.38 in wg24X24X12 (WxHxD)MERV 1412-Inch Plastic Box, Single Header, Downstream Gasket49.726 lb
1135802
Backordered
POR
Synthetic105 ft2PARKERHVAC Filtration Division12.0 lbs.500 ft/minHigh-Impact Plastic Frame Panels11.5 inchHVAC and Refrigeration23.375 inchAir2000 CFMFiltration123.375 inchExtended Surface Rigid Cell FiltersPLT12-M14-04-PH-SAAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FGoldHVAC Frame System≥ 90% : 1.0 to 3.0 micron0.38 in wg24X24X12 (WxHxD)MERV 1412-Inch Plastic Box, Single Header, Side Access Gasket
1135803
Backordered
POR
Synthetic105 ft2PARKERHVAC Filtration Division12.0 lbs.500 ft/minHigh-Impact Plastic Frame Panels11.5 inchHVAC and Refrigeration23.375 inchAir2000 CFMFiltration123.375 inchExtended Surface Rigid Cell FiltersPLT12-M14-04-PH-UAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FGoldHVAC Frame System≥ 90% : 1.0 to 3.0 micron0.38 in wg24X24X12 (WxHxD)MERV 1412-Inch Plastic Box, Single Header, Upstream Gasket
1135804
Backordered
POR
Synthetic86 ft2PARKERHVAC Filtration Division11.0 lbs.500 ft/minHigh-Impact Plastic Frame Panels11.5 inchHVAC and Refrigeration23.375 inchAir1650 CFMFiltration119.375 inchExtended Surface Rigid Cell FiltersPLT12-M14-15-PH-DAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FGoldHVAC Frame System≥ 90% : 1.0 to 3.0 micron0.38 in wg20X24X12 (WxHxD)MERV 1412-Inch Plastic Box, Single Header, Downstream Gasket
1135825
Backordered
POR
Synthetic46 ft2PARKERHVAC Filtration Division5.0 lbs.500 ft/minHigh-Impact Plastic Frame Panels11.5 inchHVAC and Refrigeration23.375 inchAir1000 CFMFiltration211.375 inchExtended Surface Rigid Cell FiltersPLT12-M14-03-PH-RAFAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FGoldHVAC Frame System≥ 90% : 1.0 to 3.0 micron0.38 in wg12X24X12 (WxHxD)MERV 1412-Inch Plastic Box, Single Header, Reverse Air Flow
1135826
Backordered
POR
Synthetic105 ft2PARKERHVAC Filtration Division11.0 lbs.500 ft/minHigh-Impact Plastic Frame Panels11.5 inchHVAC and Refrigeration23.375 inchAir2000 CFMFiltration123.375 inchExtended Surface Rigid Cell FiltersPLT12-M14-04-PH-RAFAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FGoldHVAC Frame System≥ 90% : 1.0 to 3.0 micron0.38 in wg24X24X12 (WxHxD)MERV 1412-Inch Plastic Box, Single Header, Reverse Air Flow
1135827
Backordered
POR
Synthetic105 ft2PARKERHVAC Filtration Division12.0 lbs.500 ft/minHigh-Impact Plastic Frame Panels11.5 inchHVAC and Refrigeration23.375 inchAir2000 CFMFiltration123.375 inchExtended Surface Rigid Cell FiltersPLT12-M14-04-PH-RAF-DAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FGoldHVAC Frame System≥ 90% : 1.0 to 3.0 micron0.38 in wg24X24X12 (WxHxD)MERV 1412-Inch Plastic Box, Single Header, Reverse Air Flow, Downstream Gasket
1135828
Backordered
POR
Synthetic46 ft2PARKERHVAC Filtration Division8.0 lbs.500 ft/minHigh-Impact Plastic Frame Panels11.5 inchHVAC and Refrigeration23.375 inchAir1000 CFMFiltration211.375 inchExtended Surface Rigid Cell FiltersPLT12-M14-03-PH-R-DAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FGoldHVAC Frame System≥ 90% : 1.0 to 3.0 micron0.38 in wg12X24X12 (WxHxD)MERV 1412-Inch Plastic Box, Single Header, Reverse Air Flow, Downstream Gasket
1135850
Backordered
POR
Synthetic46 ft2PARKERHVAC Filtration Division12.0 lbs.500 ft/min24 Gauge Galvanized Steel Frame11.5 inchHVAC and Refrigeration23.375 inchAir1000 CFMFiltration111.375 inchExtended Surface Rigid Cell FiltersPLT12-M14-03-PH-MCAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FGoldHVAC Frame System≥ 90% : 1.0 to 3.0 micron0.38 in wg12X24X12 (WxHxD)MERV 1412-Inch Metal Cell, Single Header
1135851
Backordered
POR
Synthetic105 ft2PARKERHVAC Filtration Division21.0 lbs.500 ft/min24 Gauge Galvanized Steel Frame11.5 inchHVAC and Refrigeration23.375 inchAir2000 CFMFiltration123.375 inchExtended Surface Rigid Cell FiltersPLT12-M14-04-PH-MCAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FGoldHVAC Frame System≥ 90% : 1.0 to 3.0 micron0.38 in wg24X24X12 (WxHxD)MERV 1412-Inch Metal Cell, Single Header
1135852
Backordered
POR
Synthetic71 ft2PARKERHVAC Filtration Division4.0 lbs.500 ft/min24 Gauge Galvanized Steel Frame11.5 inchHVAC and Refrigeration19.375 inchAir1400 CFMFiltration119.375 inchExtended Surface Rigid Cell FiltersPLT12-M14-13-PH-MCAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FGoldHVAC Frame System≥ 90% : 1.0 to 3.0 micron0.38 in wg20X20X12 (WxHxD)MERV 1412-Inch Metal Cell, Single Header
1135853
Backordered
POR
Synthetic86 ft2PARKERHVAC Filtration Division16.0 lbs.500 ft/min24 Gauge Galvanized Steel Frame11.5 inchHVAC and Refrigeration23.375 inchAir1650 CFMFiltration119.375 inchExtended Surface Rigid Cell FiltersPLT12-M14-15-PH-MCAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FGoldHVAC Frame System≥ 90% : 1.0 to 3.0 micron0.38 in wg20X24X12 (WxHxD)MERV 1412-Inch Metal Cell, Single Header
1136001
Backordered
POR
Synthetic32 ft2PARKERHVAC Filtration Division10.0 lbs.500 ft/minHigh-Impact Plastic Frame Panels3.75 inchHVAC and Refrigeration19.375 inchAir1100 CFMFiltration315.375 inchExtended Surface Rigid Cell FiltersPLT4-M11-09-NHAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FWhiteHVAC Frame System≥ 65% : 1.0 to 3.0 micron0.19 in wg16X20X4 (WxHxD)MERV 114-Inch Plastic Box, no Header11.510 lb
1136002
Backordered
POR
Synthetic38 ft2PARKERHVAC Filtration Division12.0 lbs.500 ft/minHigh-Impact Plastic Frame Panels3.75 inchHVAC and Refrigeration24.375 inchAir1400 CFMFiltration315.375 inchExtended Surface Rigid Cell FiltersPLT4-M11-10-NHAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FWhiteHVAC Frame System≥ 65% : 1.0 to 3.0 micron0.19 in wg16X25X4 (WxHxD)MERV 114-Inch Plastic Box, no Header14.388 lb
1136003
Backordered
POR
Synthetic39 ft2PARKERHVAC Filtration Division12.0 lbs.500 ft/minHigh-Impact Plastic Frame Panels3.75 inchHVAC and Refrigeration19.375 inchAir1400 CFMFiltration319.375 inchExtended Surface Rigid Cell FiltersPLT4-M11-13-NHAir FiltrationHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability170.0 °FWhiteHVAC Frame System≥ 65% : 1.0 to 3.0 micron0.19 in wg20X20X4 (WxHxD)MERV 114-Inch Plastic Box, no Header11.510 lb

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains