• Availability & Price
  • Search SKU
Filter by attributes
  • Actual Depth
  • Actual Height
  • Actual Width
  • Air Filter Frame/Header Type
  • Application
  • Brand
  • Dimensional Weight
  • Division
  • Division
  • Filter Area
More Filters...

LoadTECH - Extended Surface Rigid Cell Filters

Picture for category LoadTECH - Extended Surface Rigid Cell Filters

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Product Overview

The Parker LoadTECH® product line is comprised of extended surface rigid cell filters. All filters utilize proprietary E-Pleat® media technology, which molds filtration media into a series of pre-formed channels that direct the air smoothly through the filter, allowing for even loading and complete media utilization.
The compact 4-inch design offers the same filtration performance as a 12-inch filter, but in a much smaller envelope, resulting in simplified handling, plus reduced storage space requirements and shipping costs. The 12-inch filter performance rivals the dust holding capacity of commercial 4-V filters in the HVAC market and are of tremendous value in applications where energy and total cost of ownership are priority.
The high-impact polystyrene (HIPS) frame resists cracking and is not affected by corrosion. The media resists tearing, damage, moisture and microbial growth. The filter is also completely incinerable, which minimizes waste disposal costs.
LoadTECH® filters are available in MERV 14, MERV 11 and MERV 8 efficiency ratings per ASHRAE Standard 52.2-2017. MERV 14 and MERV 11 efficiencies are available in box and single header construction in both 4-inch and 12-inch depths. MERV 8 is available in 4-inch box frame construction. These filters are fully incinerable and ideal for use in variable air volume (VAV) systems.

Markets

• Commercial and Industrial HVAC
• Process Air Filtration

Applications

• Hotels and entertainment complexes
• Food processing
• Microelectronics manufacturing
• Data centers
• Commercial office buildings
• Schools and universities
• Clean manufacturing facilities
• Hospitals and healthcare facilities
• Government institutions
• Industrial manufacturing

Benefits


• Proprietary E-Pleat® media technology efficiently directs air flow through the filter
• Offers longer service life and fewer filter change-outs with higher dust holding capacity
• Energy savings – Low pressure drop offers reduced energy use
• Completely incinerable with high impact polystyrene (HIPS) frame
• MERV 14 meets the efficiency requirements to earn points toward LEED green building certification

Features


• Filtration efficiency rating: MERV 14, MERV 11 and MERV 8 per ASHRAE Standard 52.2-2017
• Depth (in.): 4, 12
• Construction: Available in box and single header
• Materials of construction: high-impact polystyrene (HIPS) frame, synthetic media with embossed design, adhesive beads bond pleats   into rigid pack
• Maximum operating temperature: 170 °F (77 °C)
• Rated face velocity: 500 FPM
• Recommended final resistance: 1.50” W.G.
• Classified per UL Standard 900 for Flammability

Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceFilter AreaMaterials of ConstructionActual WidthTechnologyActual DepthProduct TypeMicron RatingApplicationInitial ResistanceActual HeightSpecifications MetMedia ColorFor Fluid TypeMaximum Operating TemperatureWeightProduct StyleDivisionBrandModel NumberFilter MaterialPackage QuantityDivisionFlow RateRated Air VelocityIndustryAir Filter Frame/Header TypeNominal Filter SizeFilter Efficiency RatingDimensional Weight
1136152
Backordered
POR
36 ft2High-Impact Plastic Frame Panels19.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 65% : 1.0 to 3.0 micronAir Filtration0.25 in wg19.375 inchClassified Per UL Standard 900 for FlammabilityWhiteAir170.0 °F4.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M11-13-PH-SASynthetic3HVAC Filtration Division1400 CFM500 ft/minHVAC and Refrigeration4-Inch Plastic Box, Single Header, Side Access Gasket20X20X4 (WxHxD)MERV 11
1136153
Backordered
POR
22 ft2High-Impact Plastic Frame Panels11.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 65% : 1.0 to 3.0 micronAir Filtration0.25 in wg23.375 inchClassified Per UL Standard 900 for FlammabilityWhiteAir170.0 °F3.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M11-03-PH-SASynthetic6HVAC Filtration Division1000 CFM500 ft/minHVAC and Refrigeration4-Inch Plastic Box, Single Header, Side Access Gasket12X24X4 (WxHxD)MERV 11
1136154
Backordered
POR
44 ft2High-Impact Plastic Frame Panels19.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 65% : 1.0 to 3.0 micronAir Filtration0.25 in wg23.375 inchClassified Per UL Standard 900 for FlammabilityWhiteAir170.0 °F4.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M11-15-PH-SA NEOPRENE GSKSynthetic3HVAC Filtration Division1650 CFM500 ft/minHVAC and Refrigeration4-Inch Plastic Box, Single Header, Side Access Gasket, Neoprene Gasket20X24X4 (WxHxD)MERV 11
1136175
Backordered
POR
n/a24 Gauge Galvanized Steel Frame24.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 65% : 1.0 to 3.0 micronAir Filtration0.25 in wg19.375 inchClassified Per UL Standard 900 for FlammabilityWhiteAir170.0 °F5.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M11-12-PH-MCSynthetic3HVAC Filtration Division1750 CFM500 ft/minHVAC and Refrigeration4-Inch Metal Cell, Single Header20X25X4 (WxHxD)MERV 11
1136176
Backordered
POR
n/a24 Gauge Galvanized Steel Frame24.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 65% : 1.0 to 3.0 micronAir Filtration0.25 in wg15.375 inchClassified Per UL Standard 900 for FlammabilityWhiteAir170.0 °F8.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M11-10-PH-MCSynthetic3HVAC Filtration Division1400 CFM500 ft/minHVAC and Refrigeration4-Inch Metal Cell, Single Header16X25X4 (WxHxD)MERV 11
1136177
Backordered
POR
36 ft224 Gauge Galvanized Steel Frame19.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 65% : 1.0 to 3.0 micronAir Filtration0.25 in wg19.375 inchClassified Per UL Standard 900 for FlammabilityWhiteAir170.0 °F5.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M11-13-PH-MCSynthetic3HVAC Filtration Division1400 CFM500 ft/minHVAC and Refrigeration4-Inch Metal Cell, Single Header20X20X4 (WxHxD)MERV 11
1136178
Backordered
POR
22 ft224 Gauge Galvanized Steel Frame11.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 65% : 1.0 to 3.0 micronAir Filtration0.25 in wg23.375 inchClassified Per UL Standard 900 for FlammabilityWhiteAir170.0 °F5.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M11-03-PH-MCSynthetic6HVAC Filtration Division1000 CFM500 ft/minHVAC and Refrigeration4-Inch Metal Cell, Single Header12X24X4 (WxHxD)MERV 11
1136179
Backordered
POR
53 ft224 Gauge Galvanized Steel Frame23.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 65% : 1.0 to 3.0 micronAir Filtration0.25 in wg23.375 inchClassified Per UL Standard 900 for FlammabilityWhiteAir170.0 °F9.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M11-04-PH-MCSynthetic3HVAC Filtration Division2000 CFM500 ft/minHVAC and Refrigeration4-Inch Metal Cell, Single Header24X24X4 (WxHxD)MERV 11
1136180
Backordered
POR
53 ft224 Gauge Galvanized Steel Frame23.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 65% : 1.0 to 3.0 micronAir Filtration0.25 in wg23.375 inchClassified Per UL Standard 900 for FlammabilityWhiteAir170.0 °F9.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M11-04-PH-MC-SASynthetic3HVAC Filtration Division2000 CFM500 ft/minHVAC and Refrigeration4-Inch Metal Cell, Single Header, Side Access Gasket24X24X4 (WxHxD)MERV 11
1136181
Backordered
POR
n/a24 Gauge Galvanized Steel Frame15.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 65% : 1.0 to 3.0 micronAir Filtration0.25 in wg19.375 inchClassified Per UL Standard 900 for FlammabilityWhiteAir170.0 °F4.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M11-09-PH-MCSynthetic3HVAC Filtration Division1120 CFM500 ft/minHVAC and Refrigeration4-Inch Metal Cell, Single Header16X20X4 (WxHxD)MERV 11
1136182
Backordered
POR
44 ft224 Gauge Galvanized Steel Frame19.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 65% : 1.0 to 3.0 micronAir Filtration0.25 in wg23.375 inchClassified Per UL Standard 900 for FlammabilityWhiteAir170.0 °F8.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M11-15-PH-MCSynthetic3HVAC Filtration Division1670 CFM500 ft/minHVAC and Refrigeration4-Inch Metal Cell, Single Header20X24X4 (WxHxD)MERV 11
1136198
Backordered
POR
53 ft2High-Impact Plastic Frame Panels23.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 65% : 1.0 to 3.0 micronAir Filtration0.25 in wg23.375 inchClassified Per UL Standard 900 for FlammabilityWhiteAir170.0 °F6.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M11-04-PH-RSynthetic3HVAC Filtration Division2000 CFM500 ft/minHVAC and Refrigeration4-Inch Plastic Box, Single Header, Reverse Air Flow24X24X4 (WxHxD)MERV 11
1136199
Backordered
POR
22 ft2High-Impact Plastic Frame Panels11.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 65% : 1.0 to 3.0 micronAir Filtration0.25 in wg23.375 inchClassified Per UL Standard 900 for FlammabilityWhiteAir170.0 °F2.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M11-03-PH-RSynthetic6HVAC Filtration Division1000 CFM500 ft/minHVAC and Refrigeration4-Inch Plastic Box, Single Header, Reverse Air Flow12X24X4 (WxHxD)MERV 11
1136400
Backordered
POR
26 ft2High-Impact Plastic Frame Panels11.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 90% : 1.0 to 3.0 micronAir Filtration0.45 in wg23.375 inchClassified Per UL Standard 900 for FlammabilityGoldAir170.0 °F17.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M14-03-NHSynthetic6HVAC Filtration Division1000 CFM500 ft/minHVAC and Refrigeration4-Inch Plastic Box, no Header12X24X4 (WxHxD)MERV 148.888 lb
1136401
Backordered
POR
29 ft2High-Impact Plastic Frame Panels15.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 90% : 1.0 to 3.0 micronAir Filtration0.45 in wg19.375 inchClassified Per UL Standard 900 for FlammabilityGoldAir170.0 °F10.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M14-09-NHSynthetic3HVAC Filtration Division1100 CFM500 ft/minHVAC and Refrigeration4-Inch Plastic Box, no Header16X20X4 (WxHxD)MERV 1411.510 lb
1136402
Backordered
POR
36 ft2High-Impact Plastic Frame Panels15.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 90% : 1.0 to 3.0 micronAir Filtration0.45 in wg24.375 inchClassified Per UL Standard 900 for FlammabilityGoldAir170.0 °F12.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M14-10-NHSynthetic3HVAC Filtration Division1400 CFM500 ft/minHVAC and Refrigeration4-Inch Plastic Box, no Header16X25X4 (WxHxD)MERV 1414.388 lb
1136403
Backordered
POR
36 ft2High-Impact Plastic Frame Panels19.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 90% : 1.0 to 3.0 micronAir Filtration0.45 in wg19.375 inchClassified Per UL Standard 900 for FlammabilityGoldAir170.0 °F12.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M14-13-NHSynthetic3HVAC Filtration Division1400 CFM500 ft/minHVAC and Refrigeration4-Inch Plastic Box, no Header20X20X4 (WxHxD)MERV 1411.510 lb
1136404
Backordered
POR
44 ft2High-Impact Plastic Frame Panels19.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 90% : 1.0 to 3.0 micronAir Filtration0.45 in wg23.375 inchClassified Per UL Standard 900 for FlammabilityGoldAir170.0 °F13.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M14-15-NHSynthetic3HVAC Filtration Division1650 CFM500 ft/minHVAC and Refrigeration4-Inch Plastic Box, no Header20X24X4 (WxHxD)MERV 1414.388 lb
1136405
Backordered
POR
46 ft2High-Impact Plastic Frame Panels19.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 90% : 1.0 to 3.0 micronAir Filtration0.45 in wg24.375 inchClassified Per UL Standard 900 for FlammabilityGoldAir170.0 °F14.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M14-12-NHSynthetic3HVAC Filtration Division1750 CFM500 ft/minHVAC and Refrigeration4-Inch Plastic Box, no Header20X25X4 (WxHxD)MERV 1414.388 lb
1136406
Backordered
POR
53 ft2High-Impact Plastic Frame Panels23.375 inchFiltration3.75 inchExtended Surface Rigid Cell Filters≥ 90% : 1.0 to 3.0 micronAir Filtration0.45 in wg23.375 inchClassified Per UL Standard 900 for FlammabilityGoldAir170.0 °F15.0 lbs.HVAC Frame SystemHVAC Filtration DivisionPARKERPLT4-M14-04-NHSynthetic3HVAC Filtration Division2000 CFM500 ft/minHVAC and Refrigeration4-Inch Plastic Box, no Header24X24X4 (WxHxD)MERV 1416.575 lb

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.