• Availability & Price
  • Search SKU
Filter by attributes
  • Actual Depth
  • Actual Height
  • Actual Width
  • Air Filter Frame/Header Type
  • Application
  • Brand
  • Dimensional Weight
  • Division
  • Division
  • Filter Area
More Filters...

LoadTECH - Extended Surface Rigid Cell Filters

Picture for category LoadTECH - Extended Surface Rigid Cell Filters

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Product Overview

The Parker LoadTECH® product line is comprised of extended surface rigid cell filters. All filters utilize proprietary E-Pleat® media technology, which molds filtration media into a series of pre-formed channels that direct the air smoothly through the filter, allowing for even loading and complete media utilization.
The compact 4-inch design offers the same filtration performance as a 12-inch filter, but in a much smaller envelope, resulting in simplified handling, plus reduced storage space requirements and shipping costs. The 12-inch filter performance rivals the dust holding capacity of commercial 4-V filters in the HVAC market and are of tremendous value in applications where energy and total cost of ownership are priority.
The high-impact polystyrene (HIPS) frame resists cracking and is not affected by corrosion. The media resists tearing, damage, moisture and microbial growth. The filter is also completely incinerable, which minimizes waste disposal costs.
LoadTECH® filters are available in MERV 14, MERV 11 and MERV 8 efficiency ratings per ASHRAE Standard 52.2-2017. MERV 14 and MERV 11 efficiencies are available in box and single header construction in both 4-inch and 12-inch depths. MERV 8 is available in 4-inch box frame construction. These filters are fully incinerable and ideal for use in variable air volume (VAV) systems.

Markets

• Commercial and Industrial HVAC
• Process Air Filtration

Applications

• Hotels and entertainment complexes
• Food processing
• Microelectronics manufacturing
• Data centers
• Commercial office buildings
• Schools and universities
• Clean manufacturing facilities
• Hospitals and healthcare facilities
• Government institutions
• Industrial manufacturing

Benefits


• Proprietary E-Pleat® media technology efficiently directs air flow through the filter
• Offers longer service life and fewer filter change-outs with higher dust holding capacity
• Energy savings – Low pressure drop offers reduced energy use
• Completely incinerable with high impact polystyrene (HIPS) frame
• MERV 14 meets the efficiency requirements to earn points toward LEED green building certification

Features


• Filtration efficiency rating: MERV 14, MERV 11 and MERV 8 per ASHRAE Standard 52.2-2017
• Depth (in.): 4, 12
• Construction: Available in box and single header
• Materials of construction: high-impact polystyrene (HIPS) frame, synthetic media with embossed design, adhesive beads bond pleats   into rigid pack
• Maximum operating temperature: 170 °F (77 °C)
• Rated face velocity: 500 FPM
• Recommended final resistance: 1.50” W.G.
• Classified per UL Standard 900 for Flammability

Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceTechnologyFor Fluid TypeFlow RateInitial ResistanceMaximum Operating TemperatureActual WidthMedia ColorProduct StyleActual HeightMaterials of ConstructionActual DepthDivisionWeightSpecifications MetModel NumberMicron RatingIndustryFilter MaterialFilter AreaPackage QuantityDivisionBrandProduct TypeApplicationRated Air VelocityAir Filter Frame/Header TypeFilter Efficiency RatingNominal Filter SizeDimensional Weight
1136455
Backordered
POR
FiltrationAir1750 CFM0.45 in wg170.0 °F19.375 inchGoldHVAC Frame System24.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division5.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-12-NH-D≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic46 ft23HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, no Header, Downstream GasketMERV 1420X25X4 (WxHxD)
1136456
Backordered
POR
FiltrationAir2000 CFM0.45 in wg170.0 °F23.375 inchGoldHVAC Frame System23.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division5.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-04-NH-D≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic53 ft23HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, no Header, Downstream GasketMERV 1424X24X4 (WxHxD)
1136457
Backordered
POR
FiltrationAir2000 CFM0.45 in wg170.0 °F23.375 inchGoldHVAC Frame System23.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division5.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-04-NH-SA≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic53 ft23HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, no Header, Side Access GasketMERV 1424X24X4 (WxHxD)
1136458
Backordered
POR
FiltrationAir1100 CFM0.45 in wg170.0 °F15.375 inchGoldHVAC Frame System19.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division4.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-09-NH-SA≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic29 ft23HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, no Header, Side Access GasketMERV 1416X20X4 (WxHxD)
1136459
Backordered
POR
FiltrationAir2000 CFM0.45 in wg170.0 °F23.375 inchGoldHVAC Frame System23.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division5.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-04-NH-U≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic53 ft23HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, no Header, Upstream GasketMERV 1424X24X4 (WxHxD)
1136470
Backordered
POR
FiltrationAir2000 CFM0.45 in wg170.0 °F23.375 inchGoldHVAC Frame System23.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division5.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-04-NH-SP≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic53 ft23HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, no Header, Special GasketMERV 1424X24X4 (WxHxD)
1136471
Backordered
POR
FiltrationAir1650 CFM0.45 in wg170.0 °F19.375 inchGoldHVAC Frame System23.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division5.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-15-NH-SP≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic44 ft23HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, no Header, Special GasketMERV 1420X24X4 (WxHxD)
1136472
Backordered
POR
FiltrationAir1000 CFM0.45 in wg170.0 °F11.375 inchGoldHVAC Frame System23.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division3.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-03-NH-D≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic26 ft26HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, no Header, Downstream GasketMERV 1412X24X4 (WxHxD)
1136476
Backordered
POR
FiltrationAir1000 CFM0.45 in wg170.0 °F11.375 inchGoldHVAC Frame System23.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division3.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-03-NH-SA-SP≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic26 ft26HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, no Header, Side Access Gasket, with Special GasketMERV 1412X24X4 (WxHxD)
1136477
Backordered
POR
FiltrationAir1650 CFM0.45 in wg170.0 °F19.375 inchGoldHVAC Frame System23.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division5.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-15-NH-D≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic44 ft23HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, no Header, Side Access GasketMERV 1420X24X4 (WxHxD)
1136478
Backordered
POR
FiltrationAir1400 CFM0.45 in wg170.0 °F19.375 inchGoldHVAC Frame System19.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division4.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-13-NH-D≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic36 ft23HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, no Header, Downstream GasketMERV 1420X20X4 (WxHxD)
1136479
Backordered
POR
FiltrationAir1400 CFM0.45 in wg170.0 °F15.375 inchGoldHVAC Frame System24.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division4.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-10-NH-D≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic36 ft23HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, no Header, Downstream GasketMERV 1416X25X4 (WxHxD)
1136480
Backordered
POR
FiltrationAir1100 CFM0.45 in wg170.0 °F15.375 inchGoldHVAC Frame System19.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division4.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-09-NH-D≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic29 ft23HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, no Header, Downstream GasketMERV 1416X20X4 (WxHxD)
1136500
Backordered
POR
FiltrationAir1000 CFM0.51 in wg170.0 °F11.375 inchGoldHVAC Frame System23.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division17.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-03-PH≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic22 ft26HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, Single HeaderMERV 1412X24X4 (WxHxD)8.287 lb
1136504
Backordered
POR
FiltrationAir1650 CFM0.51 in wg170.0 °F19.375 inchGoldHVAC Frame System23.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division13.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-15-PH≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic45 ft23HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, Single HeaderMERV 1420X24X4 (WxHxD)14.388 lb
1136509
Backordered
POR
FiltrationAir1100 CFM0.51 in wg170.0 °F15.375 inchGoldHVAC Frame System19.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division3.5 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-09-PH≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic25 ft23HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, Single HeaderMERV 1416X20X4 (WxHxD)
1136510
Backordered
POR
FiltrationAir1400 CFM0.51 in wg170.0 °F15.375 inchGoldHVAC Frame System24.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division4.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-10-PH≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic34 ft23HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, Single HeaderMERV 1416X25X4 (WxHxD)
1136512
Backordered
POR
FiltrationAir1750 CFM0.51 in wg170.0 °F19.375 inchGoldHVAC Frame System24.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division5.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-12-PH≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic44 ft23HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, Single HeaderMERV 1420X25X4 (WxHxD)
1136513
Backordered
POR
FiltrationAir1400 CFM0.51 in wg170.0 °F19.375 inchGoldHVAC Frame System19.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division12.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-13-PH≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic37 ft23HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, Single HeaderMERV 1420X20X4 (WxHxD)11.510 lb
1136516
Backordered
POR
FiltrationAir2000 CFM0.51 in wg170.0 °F23.375 inchGoldHVAC Frame System23.375 inchHigh-Impact Plastic Frame Panels3.75 inchHVAC Filtration Division15.0 lbs.Classified Per UL Standard 900 for FlammabilityPLT4-M14-04-PH≥ 90% : 1.0 to 3.0 micronHVAC and RefrigerationSynthetic53 ft23HVAC Filtration DivisionPARKERExtended Surface Rigid Cell FiltersAir Filtration500 ft/min4-Inch Plastic Box, Single HeaderMERV 1424X24X4 (WxHxD)16.575 lb

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains