Pilot Operated Servo Proportional Directional Control Valve - Series D31FP / D41FP / D91FP / D111FP

Picture for category Pilot Operated Servo Proportional Directional Control Valve - Series D31FP / D41FP / D91FP / D111FP

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The top-level series of pilot operated servo proportional valves D*1FP is the ultimate choice for highest accuracy in positioning of hydraulic axis and controlling of pressure and velocity. It shows extremly high dynamics combined with high flow. It  The D*1FP series transfers the advantages of the Parker patented Voice Coil Drive (VCD) to larger frame sizes and thus high flow rates. The high dynamics/ high precision drive of the pilot valve allows the optimum control of the main spool and results in servo class performance of the complete valves.

The D*1FP series is available in 5 sizes:
• D31FP NG10 (CETOP 05)
• D41FP NG16 (CETOP 07)
• D91FP NG25 (CETOP 08) for port diameter up to 32 mm
• D111FP NG32 (CETOP 10)

Optionally available with EtherCAT® interface
The valves series D*1FP with EtherCAT® interface fulfill  the requirements of modern communication between valve and main control. Due to high data transmission speed and short cycle times, the high dynamics can be also utilized within the fieldbus system.

Markets:
• Industrial
• Machine tools
• Molding

Features/Benefits:
• Highest dynamics - shorter cycle times and thus higher machine output
• High flow capacity - optimum efficiency in relation to valve size
• High-resolution position feedback on main spool - assures stable spool position
• Progressive main spool design (sinus characteristics) - high-resolution position control at small command signals and for high flows where desirable
• Defined spool positioning at power-down - optional P-A/B-T or P-B/A-T or center position (for overlapped spools)
• IO-Link interface for parametrizing
• RGB diode for optical status check
• NFC interface
• Digital electronics - permits to store and load valve records
• Optionally with EtherCAT interface, 2x M12x1, connector 4-Pin (Ether-CAT In and EtherCAT Out) - high dynamics can be also utilized within the fieldbus system
• Very robust valve design - lower costs through less downtime
• Short delivery time - no warehousing necessary

Applications:
• General presses
• Die cast
• Injection molding
• Pulp & paper

Technical specifications:
The safety concept works with a safe 4th position at the D1FP pilot valve. This ensures that the main stage is hydraulically balanced at power down and allows to have the main spool spring centered (for overlapped spools) or approximately 10 % spring offset to spool position A or B (for zerolap spools).

Note: The versions with Regenerative or hybrid function are no longer available.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceBrandFunctionDivisionMaximum Operating PressureMounting TypeSeal MaterialOperation TypeTechnologyBody MaterialFlow RateMediaApplicationMaximum Ambient TemperatureMaximum Kinematic ViscosityMinimum Ambient TemperatureMinimum Fluid TemperatureFilter Efficiency RatingMaximum Flow RateFor Fluid TypeMinimum Kinematic ViscosityValve TypeDivisionProduct SeriesMaximum Fluid TemperatureElectronics TypeMaximum Pilot PressureIngress Protection RatingVariation of Opening PointMounting StyleMinimum Pilot PressureActuation TypeMounting PositionPower Supply VoltageVibration ResistanceLeak RateHysteresisPort ConnectionPressure DifferentialWeightResponse TimeSeal MaterialPort ConnectionFlow RateSignal InputFlow DirectionPilot Inlet / Drain LocationsSpool CodeValve OptionConnection TypeSpool TypePressure Differential (bar)Defined Spool Position At Power DownMaximum Flow RateMaterial - SealsTypeSeriesNominal SizeMaximum Flow Rate (lpm)Pilot Connection (Inlet/Drain)Electrical ConnectionFlow Rate (lpm)
D81FPE52HB4NK00
Backordered
POR
PARKER3-WayIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast Iron450 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °CISO 4406 18/16/131000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalISO 440120 barVCD®-actuatorPreferably HorizontalElectric Shut-off at < 19 V Nominal (tolerance range 22 … 30)10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64Depending on Spool< 0.1 %NG16 / CETOP 075.0 bar23.5 kg19 msNBRNG25 / CETOP 08450 l/min0-±10 V0-10 V = P-AInternal/internalE52Standard and regenerative valve function6+PEZerolap5P-B/A-T1000 L/MIN
D81FPE52HB5NK00
Backordered
POR
PARKER3-WayIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast Iron400 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °CISO 4406 18/16/131000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalNFPA20 barVCD®-actuatorPreferably HorizontalRipple < 5 V % Eff.15 Shock Acc. IEC 60068-2-27Depending on Spool< 0.1 %NG32 / CETOP 105.0 bar23.5 kg19 msNBRNG25 / CETOP 08400 l/min0-±10 V0-10 V = P-AExternal/internalE52Standard and regenerative valve function6+PEZerolap5P-B/A-T1000 L/MIN
D81FPE52HC2NB00
Backordered
POR
PARKERProportionalIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast Iron450 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °CISO 4406 18/16/131000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalCETOP RP12120 barVCD®-actuatorPreferably HorizontalRipple < 5 V % Eff.10 Sinus 5...2000 Hz Acc. IEC 60068-2-6Depending on Spool< 0.1 %NG32 / CETOP 105.0 bar23.5 kg19 msNBRNG25 / CETOP 08450 l/min0-±10 V0-10 V = P-BExternal/externalE52Standard and regenerative valve function6+PEZerolap5Center position1000 L/MIN
D81FPE52HC2NK00
Backordered
POR
PARKERProportionalIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast Iron450 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-25 °CISO 4406 18/16/131000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 2434020 barVCD®-actuatorPreferably Horizontal24 V Nominal (tolerance range 22 … 30)15 Shock Acc. IEC 60068-2-27Depending on Spool< 0.1 %NG10 / CETOP 055.0 bar23.5 kg19 msNBRNG25 / CETOP 08450 l/min0-±10 V0-10 V = P-AExternal/externalE52Standard and regenerative valve function6+PEZerolap5Center position1000 L/MIN
D81FPE52HC2NS00
Backordered
POR
PARKERProportionalIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast Iron450 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °CISO 4406 18/16/131000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalNFPA20 barVCD®-actuatorPreferably Horizontal24 V Nominal (tolerance range 22 … 30)10 Sinus 5...2000 Hz Acc. IEC 60068-2-6Depending on Spool< 0.1 %NG10 / CETOP 055.0 bar23.5 kg19 msNBRNG25 / CETOP 08450 l/min4-20 mA12-20 mA = P-AExternal/externalE52Standard and regenerative valve function6+PEZerolap5Center position1000 L/MIN
D81FPE52HC2VK00
Backordered
POR
PARKERProportionalIndustrial Systems Division Europe350 barSubplateFPMPilotHydraulicsCast Iron450 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °CISO 4406 18/16/131000 L/minOthers20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 2434020 barVCD®-actuatorPreferably HorizontalSurge Free V % Eff.10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64Depending on Spool< 0.1 %NG10 / CETOP 055.0 bar23.5 kg19 msFPMNG25 / CETOP 08450 l/min0-±10 V0-10 V = P-AExternal/externalE52Standard and regenerative valve function6+PEZerolap5Center position1000 L/MIN
D81FPE52HC4NB00
Backordered
POR
PARKERProportionalIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast Iron400 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °CISO 4406 18/16/131000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalNFPA20 barVCD®-actuatorPreferably Horizontal24 V Nominal (tolerance range 22 … 30)10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64Depending on Spool< 0.1 %NG16 / CETOP 075.0 bar23.5 kg19 msNBRNG25 / CETOP 08400 l/min0-±10 V0-10 V = P-BInternal/internalE52Standard and regenerative valve function6+PEZerolap5Center position1000 L/MIN
D81FPE52HC4NS00
Backordered
POR
PARKER3-WayIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast Iron400 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °CISO 4406 18/16/131000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalNFPA20 barVCD®-actuatorPreferably Horizontal24 V Nominal (tolerance range 22 … 30)15 Shock Acc. IEC 60068-2-27Depending on Spool< 0.1 %NG32 / CETOP 105.0 bar23.5 kg19 msNBRNG25 / CETOP 08400 l/min4-20 mA12-20 mA = P-AInternal/internalE52Standard and regenerative valve function6+PEZerolap5Center position1000 L/MIN
D91FPB31HC1NB00
Backordered
POR
PARKERProportional, 3-wayIndustrial Systems Division Europe350 barSubplate mountingNBRPilotHydraulicsCast Iron450.0 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °CISO 4406; 18/16/131000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard Electronics350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 24340 / ISO 4401 / CETOP RP121 / NFPA20 barVCD®-actuatorHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gDepending on Spool< 0.1 %NG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 105.0 bar23.5 kg19 msNBRNG25 / CETOP 08450 l/min0-±10 V0-10 V = P-BInternal/externalB31Standard and regenerative valve function6+PEOverlap5Center position1000 L/MIN
D91FPB31HC1NS00
Backordered
POR
PARKERProportional, 3-wayIndustrial Systems Division Europe350 barSubplate mountingNBRPilotHydraulicsCast Iron450.0 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °CISO 4406; 18/16/131000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard Electronics350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 24340 / ISO 4401 / CETOP RP121 / NFPA20 barVCD®-actuatorHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gDepending on Spool< 0.1 %NG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 105.0 bar23.5 kg19 msNBRNG25 / CETOP 08450 l/min4-20 mA12-20 mA = P-AInternal/externalB31Standard and regenerative valve function6+PEOverlap5Center position1000 L/MINNBROverlapD91FP, port size 32 mmNG25 / CETOP 081000Internal/external
D91FPB31HC1VK00
Backordered
POR
PARKERProportional, 3-wayIndustrial Systems Division Europe350 barSubplate mountingFPMPilotHydraulicsCast Iron450.0 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °CISO 4406; 18/16/131000 L/minHydraulic Oil20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard Electronics350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 24340 / ISO 4401 / CETOP RP121 / NFPA20 barVCD®-actuatorHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gDepending on Spool< 0.1 %NG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 105.0 bar23.5 kg19 msFPMNG25 / CETOP 08450 l/min0-±10 V0-10 V = P-AInternal/externalB31Standard and regenerative valve function6+PEOverlap5Center position1000 L/MIN
D91FPB31HC2NK00
Backordered
POR
PARKERProportional, 3-wayIndustrial Systems Division Europe350 barSubplate mountingNBRPilotHydraulicsCast Iron450.0 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °CISO 4406; 18/16/131000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard Electronics350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 24340 / ISO 4401 / CETOP RP121 / NFPA20 barVCD®-actuatorHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gDepending on Spool< 0.1 %NG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 105.0 bar23.5 kg19 msNBRNG25 / CETOP 08450 l/min0-±10 V0-10 V = P-AExternal/externalB31Standard and regenerative valve function6+PEOverlap5Center position1000 L/MINNBROverlapD91FP, port size 32 mmNG25 / CETOP 081000External/external0-±10 (V)450
D91FPB31HC2NK70
Backordered
POR
PARKERProportional, 3-wayIndustrial Systems Division Europe350 barSubplate mountingNBRPilotHydraulicsCast Iron450.0 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °CISO 4406; 18/16/131000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard Electronics350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 24340 / ISO 4401 / CETOP RP121 / NFPA20 barVCD®-actuatorHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gDepending on Spool< 0.1 %NG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 105.0 bar23.5 kg19 msNBRNG25 / CETOP 08450 l/min0-±10 V0-10 V = P-AExternal/externalB31Standard and regenerative valve function6+PE + enableOverlap5Center position1000 L/MIN
D91FPB31HC2NS00
Backordered
POR
PARKERProportional, 3-wayIndustrial Systems Division Europe350 barSubplate mountingNBRPilotHydraulicsCast Iron450.0 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °CISO 4406; 18/16/131000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard Electronics350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 24340 / ISO 4401 / CETOP RP121 / NFPA20 barVCD®-actuatorHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gDepending on Spool< 0.1 %NG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 105.0 bar23.5 kg19 msNBRNG25 / CETOP 08450 l/min4-20 mA12-20 mA = P-AExternal/externalB31Standard and regenerative valve function6+PEOverlap5Center position1000 L/MIN
D91FPB31HC2NS70
Backordered
POR
PARKERProportional, 3-wayIndustrial Systems Division Europe350 barSubplate mountingNBRPilotHydraulicsCast Iron450.0 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-25 °CISO 4406; 18/16/131000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard Electronics350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 24340 / ISO 4401 / CETOP RP121 / NFPA20 barVCD®-actuatorHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gDepending on Spool< 0.1 %NG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 105.0 bar23.5 kg19 msNBRNG25 / CETOP 08450 l/min4-20 mA12-20 mA = P-AExternal/externalB31Standard and regenerative valve function6+PEOverlap5Center position1000 L/MIN
D91FPB31HC4NB00
Backordered
POR
PARKERProportional, 3-wayIndustrial Systems Division Europe350 barSubplate mountingNBRPilotHydraulicsCast Iron450.0 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °CISO 4406; 18/16/131000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard Electronics350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 24340 / ISO 4401 / CETOP RP121 / NFPA20 barVCD®-actuatorHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gDepending on Spool< 0.1 %NG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 105.0 bar23.5 kg19 msNBRNG25 / CETOP 08450 l/min0-±10 V0-10 V = P-BInternal/internalB31Standard and regenerative valve function6+PEOverlap5Center position1000 L/MIN
D91FPB31HC4NB70
Backordered
POR
PARKERProportional, 3-wayIndustrial Systems Division Europe350 barSubplate mountingNBRPilotHydraulicsCast Iron450.0 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-25 °CISO 4406; 18/16/131000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard Electronics350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 24340 / ISO 4401 / CETOP RP121 / NFPA20 barVCD®-actuatorHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gDepending on Spool< 0.1 %NG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 105.0 bar23.5 kg19 msNBRNG25 / CETOP 08450 l/min0-±10 V0-10 V = P-BInternal/internalB31Standard and regenerative valve function6+PE + enableOverlap5Center position1000 L/MIN
D91FPB31HC4VK00
Backordered
POR
PARKERProportional, 3-wayIndustrial Systems Division Europe350 barSubplate mountingFPMPilotHydraulicsCast Iron450.0 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °CISO 4406; 18/16/131000 L/minHydraulic Oil20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard Electronics350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 24340 / ISO 4401 / CETOP RP121 / NFPA20 barVCD®-actuatorHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gDepending on Spool< 0.1 %NG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 105.0 bar23.5 kg19 msFPMNG25 / CETOP 08450 l/min0-±10 V0-10 V = P-AInternal/internalB31Standard and regenerative valve function6+PEOverlap5Center position1000 L/MIN
D91FPB32HC1NB00
Backordered
POR
PARKERProportional, 3-wayIndustrial Systems Division Europe350 barSubplate mountingNBRPilotHydraulicsCast Iron450.0 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °CISO 4406; 18/16/131000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard Electronics350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 24340 / ISO 4401 / CETOP RP121 / NFPA20 barVCD®-actuatorHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gDepending on Spool< 0.1 %NG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 105.0 bar23.5 kg19 msNBRNG25 / CETOP 08450 l/min0-±10 V0-10 V = P-BInternal/externalB32Standard and regenerative valve function6+PEOverlap5Center position1000 L/MIN
D91FPB32HC1NN00
Backordered
POR
PARKERProportional, 3-wayIndustrial Systems Division Europe350 barSubplate mountingNBRPilotHydraulicsCast Iron450.0 L/minHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °CISO 4406; 18/16/131000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard Electronics350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 24340 / ISO 4401 / CETOP RP121 / NFPA20 barVCD®-actuatorHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gDepending on Spool< 0.1 %NG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 105.0 bar23.5 kg19 msNBRNG25 / CETOP 08450 l/minEtherCAT bus type N0 - 4096 = P-AInternal/externalB32Standard and regenerative valve function6+PEOverlap5Center position1000 L/MIN

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains