• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Application
  • Body Material
  • Brand
  • Connection Type
  • Defined Spool Position At Power Down
  • Division
  • Division
  • Electrical Connection
  • Electronics Type
More Filters...

Pilot Operated Servo Proportional Directional Control Valve - Series D31FP / D41FP / D91FP / D111FP

Picture for category Pilot Operated Servo Proportional Directional Control Valve - Series D31FP / D41FP / D91FP / D111FP

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The top-level series of pilot operated servo proportional valves D*1FP is the ultimate choice for highest accuracy in positioning of hydraulic axis and controlling of pressure and velocity. It shows extremly high dynamics combined with high flow. It  The D*1FP series transfers the advantages of the Parker patented Voice Coil Drive (VCD) to larger frame sizes and thus high flow rates. The high dynamics/ high precision drive of the pilot valve allows the optimum control of the main spool and results in servo class performance of the complete valves.

The D*1FP series is available in 5 sizes:
• D31FP NG10 (CETOP 05)
• D41FP NG16 (CETOP 07)
• D91FP NG25 (CETOP 08) for port diameter up to 32 mm
• D111FP NG32 (CETOP 10)

Optionally available with EtherCAT® interface
The valves series D*1FP with EtherCAT® interface fulfill  the requirements of modern communication between valve and main control. Due to high data transmission speed and short cycle times, the high dynamics can be also utilized within the fieldbus system.

Markets:
• Industrial
• Machine tools
• Molding

Features/Benefits:
• Highest dynamics - shorter cycle times and thus higher machine output
• High flow capacity - optimum efficiency in relation to valve size
• High-resolution position feedback on main spool - assures stable spool position
• Progressive main spool design (sinus characteristics) - high-resolution position control at small command signals and for high flows where desirable
• Defined spool positioning at power-down - optional P-A/B-T or P-B/A-T or center position (for overlapped spools)
• IO-Link interface for parametrizing
• RGB diode for optical status check
• NFC interface
• Digital electronics - permits to store and load valve records
• Optionally with EtherCAT interface, 2x M12x1, connector 4-Pin (Ether-CAT In and EtherCAT Out) - high dynamics can be also utilized within the fieldbus system
• Very robust valve design - lower costs through less downtime
• Short delivery time - no warehousing necessary

Applications:
• General presses
• Die cast
• Injection molding
• Pulp & paper

Technical specifications:
The safety concept works with a safe 4th position at the D1FP pilot valve. This ensures that the main stage is hydraulically balanced at power down and allows to have the main spool spring centered (for overlapped spools) or approximately 10 % spring offset to spool position A or B (for zerolap spools).

Note: The versions with Regenerative or hybrid function are no longer available.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceBrandDivisionMaximum Operating PressureSeal MaterialOperation TypeTechnologyBody MaterialMediaApplicationMaximum Ambient TemperatureMaximum Kinematic ViscosityMinimum Ambient TemperatureMinimum Fluid TemperatureMaximum Flow RateFor Fluid TypeMinimum Kinematic ViscosityFilter Efficiency RatingValve TypeDivisionProduct SeriesMaximum Fluid TemperatureMounting StyleMaximum Pilot PressureIngress Protection RatingVariation of Opening PointMinimum Pilot PressureActuation TypeLeak RateHysteresisPressure DifferentialMounting TypeWeightResponse TimeFlow RateFunctionElectronics TypeMounting PositionPower Supply VoltageVibration ResistancePort ConnectionSeal MaterialPort ConnectionFlow RateSpool CodeSignal InputFlow DirectionPilot Inlet / Drain LocationsValve OptionConnection TypeSpool TypePressure Differential (bar)Defined Spool Position At Power DownMaximum Flow Rate
D91FPB32HC1NS00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA350 barIP65 in accordance with EN 60529set to 10 % command signal20 barVCD®-actuatorDepending on Spool< 0.1 %5.0 barSubplate mounting23.5 kg19 ms450.0 L/minProportional, 3-wayOnboard ElectronicsHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gNG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 10NBRNG25 / CETOP 08450 l/minB324-20 mA12-20 mA = P-AInternal/externalStandard and regenerative valve function6+PEOverlap5Center position1000 L/MIN
D91FPB32HC1NS70
Backordered
POR
PARKERIndustrial Systems Division Europe350 barNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA350 barIP65 in accordance with EN 60529set to 10 % command signal20 barVCD®-actuatorDepending on Spool< 0.1 %5.0 barSubplate mounting23.5 kg19 ms450.0 L/minProportional, 3-wayOnboard ElectronicsHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gNG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 10NBRNG25 / CETOP 08450 l/minB324-20 mA12-20 mA = P-AInternal/externalStandard and regenerative valve function6+PE + enableOverlap5Center position1000 L/MIN
D91FPB32HC2NB00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA350 barIP65 in accordance with EN 60529set to 10 % command signal20 barVCD®-actuatorDepending on Spool< 0.1 %5.0 barSubplate mounting23.5 kg19 ms450.0 L/minProportional, 3-wayOnboard ElectronicsHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gNG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 10NBRNG25 / CETOP 08450 l/minB320-±10 V0-10 V = P-BExternal/externalStandard and regenerative valve function6+PEOverlap5Center position1000 L/MIN
D91FPB32HC2NK00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-25 °C1000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA350 barIP65 in accordance with EN 60529set to 10 % command signal20 barVCD®-actuatorDepending on Spool< 0.1 %5.0 barSubplate mounting23.5 kg19 ms450.0 L/minProportional, 3-wayOnboard ElectronicsHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gNG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 10NBRNG25 / CETOP 08450 l/minB320-±10 V0-10 V = P-AExternal/externalStandard and regenerative valve function6+PEOverlap5Center position1000 L/MIN
D91FPB32HC2NK70
Backordered
POR
PARKERIndustrial Systems Division Europe350 barNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA350 barIP65 in accordance with EN 60529set to 10 % command signal20 barVCD®-actuatorDepending on Spool< 0.1 %5.0 barSubplate mounting23.5 kg19 ms450.0 L/minProportional, 3-wayOnboard ElectronicsHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gNG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 10NBRNG25 / CETOP 08450 l/minB320-±10 V0-10 V = P-AExternal/externalStandard and regenerative valve function6+PE + enableOverlap5Center position1000 L/MIN
D91FPB32HC2NS00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-25 °C1000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA350 barIP65 in accordance with EN 60529set to 10 % command signal20 barVCD®-actuatorDepending on Spool< 0.1 %5.0 barSubplate mounting23.5 kg19 ms450.0 L/minProportional, 3-wayOnboard ElectronicsHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gNG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 10NBRNG25 / CETOP 08450 l/minB324-20 mA12-20 mA = P-AExternal/externalStandard and regenerative valve function6+PEOverlap5Center position1000 L/MIN
D91FPB32HC4HS70
Backordered
POR
PARKERIndustrial Systems Division Europe350 barFor HFC FluidsPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/minWater Glycol20 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA350 barIP65 in accordance with EN 60529set to 10 % command signal20 barVCD®-actuatorDepending on Spool< 0.1 %5.0 barSubplate mounting23.5 kg19 ms450.0 L/minProportional, 3-wayOnboard ElectronicsHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gNG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 10for HFC fluidNG25 / CETOP 08450 l/minB324-20 mA12-20 mA = P-AInternal/internalStandard and regenerative valve function6+PE + enableOverlap5Center position1000 L/MIN
D91FPB32HC4NB00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-25 °C1000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA350 barIP65 in accordance with EN 60529set to 10 % command signal20 barVCD®-actuatorDepending on Spool< 0.1 %5.0 barSubplate mounting23.5 kg19 ms450.0 L/minProportional, 3-wayOnboard ElectronicsHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gNG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 10NBRNG25 / CETOP 08450 l/minB320-±10 V0-10 V = P-BInternal/internalStandard and regenerative valve function6+PEOverlap5Center position1000 L/MIN
D91FPB32HC4NS00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA350 barIP65 in accordance with EN 60529set to 10 % command signal20 barVCD®-actuatorDepending on Spool< 0.1 %5.0 barSubplate mounting23.5 kg19 ms450.0 L/minProportional, 3-wayOnboard ElectronicsHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gNG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 10NBRNG25 / CETOP 08450 l/minB324-20 mA12-20 mA = P-AInternal/internalStandard and regenerative valve function6+PEOverlap5Center position1000 L/MIN
D91FPB61HA1NB00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA350 barIP65 in accordance with EN 60529set to 10 % command signal20 barVCD®-actuatorDepending on Spool< 0.1 %5.0 barSubplate mounting23.5 kg19 ms450.0 L/minProportional, 3-wayOnboard ElectronicsHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gNG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 10NBRNG25 / CETOP 08450 l/minB610-±10 V0-10 V = P-BInternal/externalStandard and regenerative valve function6+PEZerolap5P-A/B-T1000 L/MIN
D91FPB61HA1NS00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA350 barIP65 in accordance with EN 60529set to 10 % command signal20 barVCD®-actuatorDepending on Spool< 0.1 %5.0 barSubplate mounting23.5 kg19 ms450.0 L/minProportional, 3-wayOnboard ElectronicsHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gNG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 10NBRNG25 / CETOP 08450 l/minB614-20 mA12-20 mA = P-AInternal/externalStandard and regenerative valve function6+PEZerolap5P-A/B-T1000 L/MIN
D91FPB61HA2NB70
Backordered
POR
PARKERIndustrial Systems Division Europe350 barNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA350 barIP65 in accordance with EN 60529set to 10 % command signal20 barVCD®-actuatorDepending on Spool< 0.1 %5.0 barSubplate mounting23.5 kg19 ms450.0 L/minProportional, 3-wayOnboard ElectronicsHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gNG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 10NBRNG25 / CETOP 08450 l/minB610-±10 V0-10 V = P-BExternal/externalStandard and regenerative valve function6+PE + enableZerolap5P-A/B-T1000 L/MIN
D91FPB61HA2NE70
Backordered
POR
PARKERIndustrial Systems Division Europe350 barNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA350 barIP65 in accordance with EN 60529set to 10 % command signal20 barVCD®-actuatorDepending on Spool< 0.1 %5.0 barSubplate mounting23.5 kg19 ms450.0 L/minProportional, 3-wayOnboard ElectronicsHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gNG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 10NBRNG25 / CETOP 08450 l/minB610-±20 mA0-20 mA = P-BExternal/externalStandard and regenerative valve function6+PE + enableZerolap5P-A/B-T1000 L/MIN
D91FPB61HB1NB00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA350 barIP65 in accordance with EN 60529set to 10 % command signal20 barVCD®-actuatorDepending on Spool< 0.1 %5.0 barSubplate mounting23.5 kg19 ms450.0 L/minProportional, 3-wayOnboard ElectronicsHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gNG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 10NBRNG25 / CETOP 08450 l/minB610-±10 V0-10 V = P-BInternal/externalStandard and regenerative valve function6+PEZerolap5P-B/A-T1000 L/MIN
D91FPB61HB1NB70
Backordered
POR
PARKERIndustrial Systems Division Europe350 barNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA350 barIP65 in accordance with EN 60529set to 10 % command signal20 barVCD®-actuatorDepending on Spool< 0.1 %5.0 barSubplate mounting23.5 kg19 ms450.0 L/minProportional, 3-wayOnboard ElectronicsHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gNG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 10NBRNG25 / CETOP 08450 l/minB610-±10 V0-10 V = P-BInternal/externalStandard and regenerative valve function6+PE + enableZerolap5P-B/A-T1000 L/MIN
D91FPB61HB1NK00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA350 barIP65 in accordance with EN 60529set to 10 % command signal20 barVCD®-actuatorDepending on Spool< 0.1 %5.0 barSubplate mounting23.5 kg19 ms450.0 L/minProportional, 3-wayOnboard ElectronicsHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gNG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 10NBRNG25 / CETOP 08450 l/minB610-±10 V0-10 V = P-AInternal/externalStandard and regenerative valve function6+PEZerolap5P-B/A-T1000 L/MIN
D91FPB61HB1NK70
Backordered
POR
Industrial Systems Division EuropeNBRNG25 / CETOP 08450 l/minB610-±10 V0-10 V = P-AInternal/externalStandard and regenerative valve function6+PE + enableZerolap5P-B/A-T1000 L/MIN
D91FPB61HB2NB00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA350 barIP65 in accordance with EN 60529set to 10 % command signal20 barVCD®-actuatorDepending on Spool< 0.1 %5.0 barSubplate mounting23.5 kg19 ms450.0 L/minProportional, 3-wayOnboard ElectronicsHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gNG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 10NBRNG25 / CETOP 08450 l/minB610-±10 V0-10 V = P-BExternal/externalStandard and regenerative valve function6+PEZerolap5P-B/A-T1000 L/MIN
D91FPB61HB2NB70
Backordered
POR
PARKERIndustrial Systems Division Europe350 barNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/minHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA350 barIP65 in accordance with EN 60529set to 10 % command signal20 barVCD®-actuatorDepending on Spool< 0.1 %5.0 barSubplate mounting23.5 kg19 ms450.0 L/minProportional, 3-wayOnboard ElectronicsHorizontal mounting preferred24 nominal (tolerance range 22 … 30), electric shut-off at < 19, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-64 15 Shock acc. IEC 60068-2-27 gNG10 / CETOP 05, NG16 / CETOP 07, NG25 / CETOP 08, NG32 / CETOP 10NBRNG25 / CETOP 08450 l/minB610-±10 V0-10 V = P-BExternal/externalStandard and regenerative valve function6+PE + enableZerolap5P-B/A-T1000 L/MIN
D91FPB61HB2NE70
Backordered
POR
Industrial Systems Division EuropeNBRNG25 / CETOP 08450 l/minB610-±20 mA0-20 mA = P-BExternal/externalStandard and regenerative valve function6+PE + enableZerolap5P-B/A-T1000 L/MIN

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains