R9 Valve - 9 mm Miniature Diaphragm Isolation Valve

Picture for category R9 Valve - 9 mm Miniature Diaphragm Isolation Valve

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The Parker R9 valve delivers the liquid flow capabilities of a 16 mm valve in a 9 mm envelope. The R9 valve includes a 44% reduction in width with unrivaled flows and pressures up to 100 psi. Designed to offer low carryover performance with particulate and crystallization resistance, this valve is ideally suited for today’s demanding liquid handling applications. The R9 supports the performance requirements of current and future laboratory and portable instrumentation.

Markets:
• Clinical Diagnostics
• Analytical Chemistry
• Agent Detection
• Environmental Monitoring

Features/Benefits
• High pressure options available up to 100 PSI (6.9 bar)
• Easy mounting on 9 mm centers side to side, accommodating dispense over 96 well microplates
• Low unswept volume to minimize carryover
• Particulate and crystallization resistant
• 100% tested leak rate ensures a leak tight seal on every valve
• CE, REACH, and RoHS compliant

Applications:
• Sampling, Wash & Waste
• Reagent Addition
• Flow Control
• Clinical Diagnostics Instrumentation
• Hematology
• Automated Slide Stainers
• DNA/RNA Synthesis

Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceDivisionStandard Lead TimeOut of Stock Lead TimeLeak RateBody MaterialConfigurationInput VoltageMounting TypeSeal MaterialActuation TypeFor Fluid TypeOperation TypeCycles per LifetimeMaximum Operating PressureMaximum Operating TemperatureMinimum Operating TemperatureMax Order QuantityConnection TypeValve TypeElectrical ConnectionHeightShipping WeightWidthFunctionResponse TimeControl MethodIndustry ApplicationLengthWeightFlow RateOrifice SizeConnection SizeMaximum Flow RatePower ConsumptionValve TypeElastomerElectrical ConnectionMaximum Operating VoltageOrifice SizeMounting StyleApplication Pressure Requirement
R9-212EP6LFF-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewEPDMSolenoidLiquidsElectronic10 Million20 psi50 °C0 °C10Manifold Face SealDiaphragm Rocker Isolation ValveWire Leads1.46 inch0.35 oz8.7 mm2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste2.71 inch38.4 gUp to 580 ml/min0.061 inchManifold face seal580 ml/min1.1 W2-Way Normally ClosedEPDM18 in(46 cm) Flying Leads12 Volt0.061 in (1.55 mm)Face Seal Manifold MountVAC to 20 psi (1.36 bar)
R9-212EP6LFP-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewEPDMSolenoidLiquidsElectronic10 Million1.4 bar50 °C32 °F10Manifold Face SealDiaphragm Rocker Isolation Valve2.54 mm pins1.46 inch0.35 oz8.7 mm2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste2.71 inch1.35 ozUp to 580 ml/min1.55 mmManifold face seal580 ml/min1.1 W2-Way Normally ClosedEPDM2.54 mm Male Pins12 Volt0.061 in (1.55 mm)Face Seal Manifold MountVAC to 20 psi (1.36 bar)
R9-212EP6LMF-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewEPDMSolenoidLiquidsElectronic10 Million20 psi122 °F0 °C10Threaded Port ConnectionsDiaphragm Rocker Isolation ValveWire Leads37 mm0.35 oz8.7 mm2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste2.71 inch38.4 gUp to 580 ml/min1.55 mmM6 threaded port connections580 ml/min1.1 W2-Way Normally ClosedEPDM18 in(46 cm) Flying Leads12 Volt0.061 in (1.55 mm)M6VAC to 20 psi (1.36 bar)
R9-212EP6LMP-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewEPDMSolenoidLiquidsElectronic10 Million1.4 bar122 °F32 °F10Threaded Port ConnectionsDiaphragm Rocker Isolation Valve2.54 mm pins1.46 inch0.35 oz8.7 mm2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste2.71 inch1.35 ozUp to 580 ml/min0.061 inchM6 threaded port connections580 ml/min1.1 W2-Way Normally ClosedEPDM2.54 mm Male Pins12 Volt0.061 in (1.55 mm)M6VAC to 20 psi (1.36 bar)
R9-212FF3H4F-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million6.9 bar122 °F32 °F10Threaded Port ConnectionsDiaphragm Rocker Isolation ValveWire Leads37 mm0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste68.8 mm1.35 ozUp to 900 ml/min0.030 inch1/4-28 UNF threaded port connections900 ml/min1.8 W2-Way Normally ClosedFFKM18 in(46 cm) Flying Leads12 Volt0.030 in (0.76 mm)1/4-28VAC to 100 psi (6.9 bar)
R9-212FF3H4P-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million6.9 bar122 °F0 °C10Threaded Port ConnectionsDiaphragm Rocker Isolation Valve2.54 mm pins37 mm0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste68.8 mm38.4 gUp to 900 ml/min0.76 mm1/4-28 UNF threaded port connections900 ml/min1.8 W2-Way Normally ClosedFFKM2.54 mm Male Pins12 Volt0.030 in (0.76 mm)1/4-28VAC to 100 psi (6.9 bar)
R9-212FF3HFF-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million6.9 bar50 °C32 °F10Manifold Face SealDiaphragm Rocker Isolation ValveWire Leads1.46 inch0.35 oz8.7 mm2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste2.71 inch38.4 gUp to 900 ml/min0.76 mmManifold face seal900 ml/min1.8 W2-Way Normally ClosedFFKM18 in(46 cm) Flying Leads12 Volt0.030 in (0.76 mm)Face Seal Manifold MountVAC to 100 psi (6.9 bar)
R9-212FF3HFP-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million100 psi50 °C32 °F10Manifold Face SealDiaphragm Rocker Isolation Valve2.54 mm pins1.46 inch0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste2.71 inch38.4 gUp to 900 ml/min0.030 inchManifold face seal900 ml/min1.8 W2-Way Normally ClosedFFKM2.54 mm Male Pins12 Volt0.030 in (0.76 mm)Face Seal Manifold MountVAC to 100 psi (6.9 bar)
R9-212FF3HMF-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million6.9 bar122 °F32 °F10Threaded Port ConnectionsDiaphragm Rocker Isolation ValveWire Leads1.46 inch0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste68.8 mm1.35 ozUp to 900 ml/min0.030 inchM6 threaded port connections900 ml/min1.8 W2-Way Normally ClosedFFKM18 in(46 cm) Flying Leads12 Volt0.030 in (0.76 mm)M6VAC to 100 psi (6.9 bar)
R9-212FF3HMP-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million100 psi122 °F0 °C10Threaded Port ConnectionsDiaphragm Rocker Isolation Valve2.54 mm pins37 mm0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste68.8 mm38.4 gUp to 900 ml/min0.76 mmM6 threaded port connections900 ml/min1.8 W2-Way Normally ClosedFFKM2.54 mm Male Pins12 Volt0.030 in (0.76 mm)M6VAC to 100 psi (6.9 bar)
R9-212FF3L4F-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million60 psi50 °C0 °C10Threaded Port ConnectionsDiaphragm Rocker Isolation ValveWire Leads1.46 inch0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste2.71 inch38.4 gUp to 600 ml/min0.76 mm1/4-28 UNF threaded port connections600 ml/min1.1 W2-Way Normally ClosedFFKM18 in(46 cm) Flying Leads12 Volt0.030 in (0.76 mm)1/4-28VAC to 60 psi (4.1 bar)
R9-212FF3L4P-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million4.1 bar122 °F32 °F10Threaded Port ConnectionsDiaphragm Rocker Isolation Valve2.54 mm pins37 mm0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste68.8 mm1.35 ozUp to 600 ml/min0.030 inch1/4-28 UNF threaded port connections600 ml/min1.1 W2-Way Normally ClosedFFKM2.54 mm Male Pins12 Volt0.030 in (0.76 mm)1/4-28VAC to 60 psi (4.1 bar)
R9-212FF3LFF-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million60 psi122 °F0 °C10Manifold Face SealDiaphragm Rocker Isolation ValveWire Leads37 mm0.35 oz8.7 mm2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste2.71 inch38.4 gUp to 600 ml/min0.030 inchManifold face seal600 ml/min1.1 W2-Way Normally ClosedFFKM18 in(46 cm) Flying Leads12 Volt0.030 in (0.76 mm)Face Seal Manifold MountVAC to 60 psi (4.1 bar)
R9-212FF3LFP-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million4.1 bar50 °C0 °C10Manifold Face SealDiaphragm Rocker Isolation Valve2.54 mm pins37 mm0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste68.8 mm38.4 gUp to 600 ml/min0.030 inchManifold face seal600 ml/min1.1 W2-Way Normally ClosedFFKM2.54 mm Male Pins12 Volt0.030 in (0.76 mm)Face Seal Manifold MountVAC to 60 psi (4.1 bar)
R9-212FF3LMF-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million4.1 bar50 °C32 °F10Threaded Port ConnectionsDiaphragm Rocker Isolation ValveWire Leads1.46 inch0.35 oz8.7 mm2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste2.71 inch38.4 gUp to 600 ml/min0.76 mmM6 threaded port connections600 ml/min1.1 W2-Way Normally ClosedFFKM18 in(46 cm) Flying Leads12 Volt0.030 in (0.76 mm)M6VAC to 60 psi (4.1 bar)
R9-212FF3LMP-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million4.1 bar122 °F32 °F10Threaded Port ConnectionsDiaphragm Rocker Isolation Valve2.54 mm pins1.46 inch0.35 oz8.7 mm2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste68.8 mm1.35 ozUp to 600 ml/min0.030 inchM6 threaded port connections600 ml/min1.1 W2-Way Normally ClosedFFKM2.54 mm Male Pins12 Volt0.030 in (0.76 mm)M6VAC to 60 psi (4.1 bar)
R9-212FF6H4F-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million2.8 bar122 °F0 °C10Threaded Port ConnectionsDiaphragm Rocker Isolation ValveWire Leads37 mm0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste68.8 mm1.35 ozUp to 700 ml/min1.55 mm1/4-28 UNF threaded port connections700 ml/min1.8 W2-Way Normally ClosedFFKM18 in(46 cm) Flying Leads12 Volt0.061 in (1.55 mm)1/4-28VAC to 40 psi (2.8 bar)
R9-212FF6H4P-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million40 psi122 °F32 °F10Threaded Port ConnectionsDiaphragm Rocker Isolation Valve2.54 mm pins1.46 inch0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste68.8 mm38.4 gUp to 700 ml/min0.061 inch1/4-28 UNF threaded port connections700 ml/min1.8 W2-Way Normally ClosedFFKM2.54 mm Male Pins12 Volt0.061 in (1.55 mm)1/4-28VAC to 40 psi (2.8 bar)
R9-212FF6HFF-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million40 psi122 °F0 °C10Manifold Face SealDiaphragm Rocker Isolation ValveWire Leads37 mm0.35 oz8.7 mm2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste2.71 inch38.4 gUp to 700 ml/min1.55 mmManifold face seal700 ml/min1.8 W2-Way Normally ClosedFFKM18 in(46 cm) Flying Leads12 Volt0.061 in (1.55 mm)Face Seal Manifold MountVAC to 40 psi (2.8 bar)
R9-212FF6HFP-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a12 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million40 psi50 °C32 °F10Manifold Face SealDiaphragm Rocker Isolation Valve2.54 mm pins1.46 inch0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste2.71 inch38.4 gUp to 700 ml/min0.061 inchManifold face seal700 ml/min1.8 W2-Way Normally ClosedFFKM2.54 mm Male Pins12 Volt0.061 in (1.55 mm)Face Seal Manifold MountVAC to 40 psi (2.8 bar)