The Parker R9 valve delivers the liquid flow capabilities of a 16 mm valve in a 9 mm envelope. The R9 valve includes a 44% reduction in width with unrivaled flows and pressures up to 100 psi. Designed to offer low carryover performance with particulate and crystallization resistance, this valve is ideally suited for today’s demanding liquid handling applications. The R9 supports the performance requirements of current and future laboratory and portable instrumentation.

Markets:
• Clinical Diagnostics
• Analytical Chemistry
• Agent Detection
• Environmental Monitoring

Features/Benefits
• High pressure options available up to 100 PSI (6.9 bar)
• Easy mounting on 9 mm centers side to side, accommodating dispense over 96 well microplates
• Low unswept volume to minimize carryover
• Particulate and crystallization resistant
• 100% tested leak rate ensures a leak tight seal on every valve
• CE, REACH, and RoHS compliant

Applications:
• Sampling, Wash & Waste
• Reagent Addition
• Flow Control
• Clinical Diagnostics Instrumentation
• Hematology
• Automated Slide Stainers
• DNA/RNA Synthesis

Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceDivisionStandard Lead TimeOut of Stock Lead TimeLeak RateBody MaterialConfigurationInput VoltageMounting TypeSeal MaterialActuation TypeFor Fluid TypeOperation TypeCycles per LifetimeMaximum Operating TemperatureMaximum Operating PressureMinimum Operating TemperatureMax Order QuantityValve TypeConnection TypeElectrical ConnectionWeightShipping WeightWidthFunctionResponse TimeControl MethodConnection SizePower ConsumptionIndustry ApplicationHeightLengthFlow RateOrifice SizeMaximum Flow RateValve TypeElastomerMounting StyleElectrical ConnectionOrifice SizeMaximum Operating VoltageApplication Pressure Requirement
R9-224EP6H4F-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewEPDMSolenoidLiquidsElectronic10 Million50 °C40 psi32 °F10Diaphragm Rocker Isolation ValveThreaded Port ConnectionsWire Leads1.35 oz0.35 oz8.7 mm2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuit1/4-28 UNF threaded port connections1.8 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste37 mm2.71 inchUp to 700 ml/min1.55 mm700 ml/min2-Way Normally ClosedEPDM1/4-2818 in(46 cm) Flying Leads0.061 in (1.55 mm)24 VoltVAC to 40 psi (2.8 bar)
R9-224EP6H4P-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewEPDMSolenoidLiquidsElectronic10 Million122 °F40 psi0 °C10Diaphragm Rocker Isolation ValveThreaded Port Connections2.54 mm pins38.4 g0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuit1/4-28 UNF threaded port connections1.8 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste1.46 inch2.71 inchUp to 700 ml/min0.061 inch700 ml/min2-Way Normally ClosedEPDM1/4-282.54 mm Male Pins0.061 in (1.55 mm)24 VoltVAC to 40 psi (2.8 bar)
R9-224EP6HFF-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewEPDMSolenoidLiquidsElectronic10 Million50 °C40 psi0 °C10Diaphragm Rocker Isolation ValveManifold Face SealWire Leads38.4 g0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitManifold face seal1.8 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste37 mm2.71 inchUp to 700 ml/min1.55 mm700 ml/min2-Way Normally ClosedEPDMFace Seal Manifold Mount18 in(46 cm) Flying Leads0.061 in (1.55 mm)24 VoltVAC to 40 psi (2.8 bar)
R9-224EP6HFP-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewEPDMSolenoidLiquidsElectronic10 Million50 °C2.8 bar32 °F10Diaphragm Rocker Isolation ValveManifold Face Seal2.54 mm pins1.35 oz0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitManifold face seal1.8 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste1.46 inch68.8 mmUp to 700 ml/min0.061 inch700 ml/min2-Way Normally ClosedEPDMFace Seal Manifold Mount2.54 mm Male Pins0.061 in (1.55 mm)24 VoltVAC to 40 psi (2.8 bar)
R9-224EP6HMF-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewEPDMSolenoidLiquidsElectronic10 Million122 °F2.8 bar32 °F10Diaphragm Rocker Isolation ValveThreaded Port ConnectionsWire Leads1.35 oz0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitM6 threaded port connections1.8 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste1.46 inch2.71 inchUp to 700 ml/min1.55 mm700 ml/min2-Way Normally ClosedEPDMM618 in(46 cm) Flying Leads0.061 in (1.55 mm)24 VoltVAC to 40 psi (2.8 bar)
R9-224EP6HMP-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewEPDMSolenoidLiquidsElectronic10 Million50 °C2.8 bar32 °F10Diaphragm Rocker Isolation ValveThreaded Port Connections2.54 mm pins1.35 oz0.35 oz8.7 mm2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitM6 threaded port connections1.8 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste37 mm2.71 inchUp to 700 ml/min0.061 inch700 ml/min2-Way Normally ClosedEPDMM62.54 mm Male Pins0.061 in (1.55 mm)24 VoltVAC to 40 psi (2.8 bar)
R9-224EP6L4F-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewEPDMSolenoidLiquidsElectronic10 Million122 °F20 psi32 °F10Diaphragm Rocker Isolation ValveThreaded Port ConnectionsWire Leads1.35 oz0.35 oz8.7 mm2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuit1/4-28 UNF threaded port connections1.2 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste1.46 inch2.71 inchUp to 580 ml/min1.55 mm580 ml/min2-Way Normally ClosedEPDM1/4-2818 in(46 cm) Flying Leads0.061 in (1.55 mm)24 VoltVAC to 20 psi (1.36 bar)
R9-224EP6L4P-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewEPDMSolenoidLiquidsElectronic10 Million50 °C1.4 bar32 °F10Diaphragm Rocker Isolation ValveThreaded Port Connections2.54 mm pins1.35 oz0.35 oz8.7 mm2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuit1/4-28 UNF threaded port connections1.2 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste1.46 inch68.8 mmUp to 580 ml/min0.061 inch580 ml/min2-Way Normally ClosedEPDM1/4-282.54 mm Male Pins0.061 in (1.55 mm)24 VoltVAC to 20 psi (1.36 bar)
R9-224EP6LFF-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewEPDMSolenoidLiquidsElectronic10 Million122 °F20 psi0 °C10Diaphragm Rocker Isolation ValveManifold Face SealWire Leads38.4 g0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitManifold face seal1.2 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste1.46 inch68.8 mmUp to 580 ml/min1.55 mm580 ml/min2-Way Normally ClosedEPDMFace Seal Manifold Mount18 in(46 cm) Flying Leads0.061 in (1.55 mm)24 VoltVAC to 20 psi (1.36 bar)
R9-224EP6LFP-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewEPDMSolenoidLiquidsElectronic10 Million50 °C1.4 bar32 °F10Diaphragm Rocker Isolation ValveManifold Face Seal2.54 mm pins38.4 g0.35 oz8.7 mm2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitManifold face seal1.2 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste37 mm2.71 inchUp to 580 ml/min1.55 mm580 ml/min2-Way Normally ClosedEPDMFace Seal Manifold Mount2.54 mm Male Pins0.061 in (1.55 mm)24 VoltVAC to 20 psi (1.36 bar)
R9-224EP6LMF-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewEPDMSolenoidLiquidsElectronic10 Million122 °F20 psi32 °F10Diaphragm Rocker Isolation ValveThreaded Port ConnectionsWire Leads38.4 g0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitM6 threaded port connections1.2 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste1.46 inch68.8 mmUp to 580 ml/min0.061 inch580 ml/min2-Way Normally ClosedEPDMM618 in(46 cm) Flying Leads0.061 in (1.55 mm)24 VoltVAC to 20 psi (1.36 bar)
R9-224EP6LMP-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewEPDMSolenoidLiquidsElectronic10 Million50 °C20 psi32 °F10Diaphragm Rocker Isolation ValveThreaded Port Connections2.54 mm pins1.35 oz0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitM6 threaded port connections1.2 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste1.46 inch68.8 mmUp to 580 ml/min0.061 inch580 ml/min2-Way Normally ClosedEPDMM62.54 mm Male Pins0.061 in (1.55 mm)24 VoltVAC to 20 psi (1.36 bar)
R9-224FF3H4F-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million122 °F6.9 bar0 °C10Diaphragm Rocker Isolation ValveThreaded Port ConnectionsWire Leads1.35 oz0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuit1/4-28 UNF threaded port connections1.8 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste37 mm2.71 inchUp to 900 ml/min0.76 mm900 ml/min2-Way Normally ClosedFFKM1/4-2818 in(46 cm) Flying Leads0.030 in (0.76 mm)24 VoltVAC to 100 psi (6.9 bar)
R9-224FF3H4P-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million50 °C100 psi32 °F10Diaphragm Rocker Isolation ValveThreaded Port Connections2.54 mm pins38.4 g0.35 oz8.7 mm2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuit1/4-28 UNF threaded port connections1.8 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste1.46 inch2.71 inchUp to 900 ml/min0.030 inch900 ml/min2-Way Normally ClosedFFKM1/4-282.54 mm Male Pins0.030 in (0.76 mm)24 VoltVAC to 100 psi (6.9 bar)
R9-224FF3HFF-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million122 °F100 psi0 °C10Diaphragm Rocker Isolation ValveManifold Face SealWire Leads1.35 oz0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitManifold face seal1.8 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste1.46 inch2.71 inchUp to 900 ml/min0.030 inch900 ml/min2-Way Normally ClosedFFKMFace Seal Manifold Mount18 in(46 cm) Flying Leads0.030 in (0.76 mm)24 VoltVAC to 100 psi (6.9 bar)
R9-224FF3HFP-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million122 °F100 psi32 °F10Diaphragm Rocker Isolation ValveManifold Face Seal2.54 mm pins1.35 oz0.35 oz8.7 mm2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitManifold face seal1.8 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste37 mm68.8 mmUp to 900 ml/min0.76 mm900 ml/min2-Way Normally ClosedFFKMFace Seal Manifold Mount2.54 mm Male Pins0.030 in (0.76 mm)24 VoltVAC to 100 psi (6.9 bar)
R9-224FF3HMF-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million122 °F100 psi0 °C10Diaphragm Rocker Isolation ValveThreaded Port ConnectionsWire Leads38.4 g0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitM6 threaded port connections1.8 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste1.46 inch68.8 mmUp to 900 ml/min0.76 mm900 ml/min2-Way Normally ClosedFFKMM618 in(46 cm) Flying Leads0.030 in (0.76 mm)24 VoltVAC to 100 psi (6.9 bar)
R9-224FF3HMP-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million50 °C100 psi0 °C10Diaphragm Rocker Isolation ValveThreaded Port Connections2.54 mm pins38.4 g0.35 oz0.34 inch2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuitM6 threaded port connections1.8 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste37 mm68.8 mmUp to 900 ml/min0.76 mm900 ml/min2-Way Normally ClosedFFKMM62.54 mm Male Pins0.030 in (0.76 mm)24 VoltVAC to 100 psi (6.9 bar)
R9-224FF3L4F-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million122 °F4.1 bar32 °F10Diaphragm Rocker Isolation ValveThreaded Port ConnectionsWire Leads38.4 g0.35 oz8.7 mm2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuit1/4-28 UNF threaded port connections1.2 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste37 mm2.71 inchUp to 600 ml/min0.030 inch600 ml/min2-Way Normally ClosedFFKM1/4-2818 in(46 cm) Flying Leads0.030 in (0.76 mm)24 VoltVAC to 60 psi (4.1 bar)
R9-224FF3L4P-000
Backordered
POR
Precision Fluidics Division2040Bubble TightPEEKn/a24 VDCMounting ScrewFFKMSolenoidLiquidsElectronic10 Million122 °F4.1 bar32 °F10Diaphragm Rocker Isolation ValveThreaded Port Connections2.54 mm pins38.4 g0.35 oz8.7 mm2-Way, Normally Closed (NC)< 18 ms max cyclingHit and hold circuit1/4-28 UNF threaded port connections1.2 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste1.46 inch68.8 mmUp to 600 ml/min0.030 inch600 ml/min2-Way Normally ClosedFFKM1/4-282.54 mm Male Pins0.030 in (0.76 mm)24 VoltVAC to 60 psi (4.1 bar)

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains