• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Adjustment Mechanism
  • Adjustment Mechanism
  • Body Material
  • Cavity Size
  • Division
  • Division
  • Filter Efficiency Rating
  • Flow Direction
  • Flow Rate
More Filters...

Standard Pilot Vented Load Control Valves

Picture for category Standard Pilot Vented Load Control Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s vented to atmosphere load holding/counterbalance valves are a combination of a relief, sequence, and flow control valve that can handle pressures up to 350 bar (5000 psi) and flows up to 113 lpm (30 gpm). These robust valves allow the operator to maintain control of the load by preventing it from overrunning the pump while also protecting against thermal expansion. The wide selection of pilot ratios enables the valve to open at pressures much lower than the spring pressure setting, allowing consistent control of the load throughout its lowering cycle. Because these valves spring chamber are vented to atmosphere, the valve will not be affected by changes in return pressure. Parker’s vented load holding valves are ideal in closed center circuits where there is need to control pressure using an auxiliary relief valve.

Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile

Features/Benefits:
• Vented to atmosphere, no additional drain line required
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios from 8:1 to 3:1
• All external parts zinc plated

Applications:
• Load holding
• Position holding

Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
The valve should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of  dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceBody MaterialMaximum Operating PressureSeal MaterialPort SizeMinimum Operating TemperatureWeightDivisionDivisionPilot LocationMaximum Kinematic ViscosityMaximum Inlet Pressure RatingMaximum Flow RateFunctionMounting TypeHolding PressureFor Fluid TypeMaximum Operating TemperatureValve MaterialOperating TemperatureFilter Efficiency RatingActuation TypeFlow RateLeak RateCavity SizeFlow DirectionInstallation TorqueAdjustment MechanismPilot Pressure RatioPressure Control RangePressure Control SensitivityPort SizeSeal MaterialMounting TypeHolding PressureMaximum Flow RateAdjustment MechanismPilot Pressure RatioPressure Control Range
MHC-010-VJSH-00B
Backordered
POR
N/A350 barNitrilen/a-30 °F0.88 lbHydraulic Systems DivisionHydraulic Cartridge Systems DivisionExternal45-2000 SSU (6 to 420 cSt)5000 psi10 Gal/minCounterbalance ValveThreaded Cartridge Valve210 barMineral-based or synthetic hydraulic fluids+121 °CAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 4Pilot Operated, Vented37.5 L/min5 @ 80% of setting drops/minCDD-1010Cylinder port 2, Valve port 3, Pilot port 150-55 lb-ftStandard (adjustable)10:1N/A barN/A psin/aNitrileThreaded Cartridge Valve3000 PSI, 210 BAR10 GAL/MIN, 37.5 L/MINStandard (adjustable)10:1N/A
MHC-010-VJSH-00F
Backordered
POR
N/A5000 psiFluorocarbonn/a-26 °C0.88 lbHydraulic Systems DivisionHydraulic Cartridge Systems DivisionExternal45-2000 SSU (6 to 420 cSt)350 bar37.5 L/minCounterbalance ValveThreaded Cartridge Valve3000 psiMineral-based or synthetic hydraulic fluids+400 °FAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 4Pilot Operated, Vented10 Gal/min5 @ 80% of setting drops/minCDD-1010Cylinder port 2, Valve port 3, Pilot port 150-55 lb-ftStandard (adjustable)10:1N/A barN/A psin/aFluorocarbonThreaded Cartridge Valve3000 PSI, 210 BAR10 GAL/MIN, 37.5 L/MINStandard (adjustable)10:1N/A
MHC-022-VCNH-00B
30 in stock
POR
N/A5000 psiNitrilen/a-34 °C0.88 lbHydraulic Systems DivisionHydraulic Cartridge Systems DivisionExternal45-2000 SSU (6 to 420 cSt)5000 psi93.75 L/minCounterbalance ValveThreaded Cartridge Valve3000 psiMineral-based or synthetic hydraulic fluids+121 °CAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 4Pilot Operated, Vented25 Gal/min5 @ 80% of setting drops/minCDD-1036Cylinder port 2, Valve port 3, Pilot port 1102-108 NmShimmed (non-adjustable)5:1N/A psiN/A barn/aNitrileThreaded Cartridge Valve3000 PSI, 210 BAR25 GAL/MIN, 93.75 L/MINShimmed (non-adjustable)5:1N/A
MHC-022-VCSH-00B
1 in stock
POR
N/A5000 psiNitrilen/a-34 °C0.88 lbHydraulic Systems DivisionHydraulic Cartridge Systems DivisionExternal45-2000 SSU (6 to 420 cSt)5000 psi93.75 L/minCounterbalance ValveThreaded Cartridge Valve3000 psiMineral-based or synthetic hydraulic fluids+121 °CAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 4Pilot Operated, Vented25 Gal/min5 @ 80% of setting drops/minCDD-1036Cylinder port 2, Valve port 3, Pilot port 1102-108 NmStandard (adjustable)5:1N/A psiN/A psin/aNitrileThreaded Cartridge Valve3000 PSI, 210 BAR25 GAL/MIN, 93.75 L/MINStandard (adjustable)5:1N/A
MHC-022-VCSH-00F
Backordered
POR
N/A350 barFluorocarbonn/a-15 °F0.88 lbHydraulic Systems DivisionHydraulic Cartridge Systems DivisionExternal45-2000 SSU (6 to 420 cSt)350 bar93.75 L/minCounterbalance ValveThreaded Cartridge Valve210 barMineral-based or synthetic hydraulic fluids+204 °CAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 4Pilot Operated, Vented93.75 L/min5 @ 80% of setting drops/minCDD-1036Cylinder port 2, Valve port 3, Pilot port 1102-108 NmStandard (adjustable)5:1N/A barN/A psin/aFluorocarbonThreaded Cartridge Valve3000 PSI, 210 BAR25 GAL/MIN, 93.75 L/MINStandard (adjustable)5:1N/A
MHC-022-VJNH-00B
Backordered
POR
N/A5000 psiNitrilen/a-30 °F0.88 lbHydraulic Systems DivisionHydraulic Cartridge Systems DivisionExternal45-2000 SSU (6 to 420 cSt)350 bar25 Gal/minCounterbalance ValveThreaded Cartridge Valve3000 psiMineral-based or synthetic hydraulic fluids+121 °CAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 4Pilot Operated, Vented25 Gal/min5 @ 80% of setting drops/minCDD-1036Cylinder port 2, Valve port 3, Pilot port 175-80 lb-ftShimmed (non-adjustable)10:1N/A psiN/A barn/aNitrileThreaded Cartridge Valve3000 PSI, 210 BAR25 GAL/MIN, 93.75 L/MINShimmed (non-adjustable)10:1N/A
MHC-022-VJNH-00F
Backordered
POR
N/A5000 psiFluorocarbonn/a-15 °F0.88 lbHydraulic Systems DivisionHydraulic Cartridge Systems DivisionExternal45-2000 SSU (6 to 420 cSt)350 bar25 Gal/minCounterbalance ValveThreaded Cartridge Valve210 barMineral-based or synthetic hydraulic fluids+400 °FAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 4Pilot Operated, Vented93.75 L/min5 @ 80% of setting drops/minCDD-1036Cylinder port 2, Valve port 3, Pilot port 175-80 lb-ftShimmed (non-adjustable)10:1N/A psiN/A psin/aFluorocarbonThreaded Cartridge Valve3000 PSI, 210 BAR25 GAL/MIN, 93.75 L/MINShimmed (non-adjustable)10:1N/A
MHC-022-VJSH-00B
Backordered
POR
N/A350 barNitrilen/a-34 °C0.88 lbHydraulic Systems DivisionHydraulic Cartridge Systems DivisionExternal45-2000 SSU (6 to 420 cSt)5000 psi25 Gal/minCounterbalance ValveThreaded Cartridge Valve3000 psiMineral-based or synthetic hydraulic fluids+121 °CAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 4Pilot Operated, Vented25 Gal/min5 @ 80% of setting drops/minCDD-1036Cylinder port 2, Valve port 3, Pilot port 1102-108 NmStandard (adjustable)10:1N/A psiN/A barn/aNitrileThreaded Cartridge Valve3000 PSI, 210 BAR25 GAL/MIN, 93.75 L/MINStandard (adjustable)10:1N/A
MHC-022-VJSH-00F
Backordered
POR
N/A5000 psiFluorocarbonn/a-15 °F0.38 kgHydraulic Systems DivisionHydraulic Cartridge Systems DivisionExternal45-2000 SSU (6 to 420 cSt)5000 psi93.75 L/minCounterbalance ValveThreaded Cartridge Valve210 barMineral-based or synthetic hydraulic fluids+400 °FAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 4Pilot Operated, Vented25 Gal/min5 @ 80% of setting drops/minCDD-1036Cylinder port 2, Valve port 3, Pilot port 175-80 lb-ftStandard (adjustable)10:1N/A barN/A barn/aFluorocarbonThreaded Cartridge Valve3000 PSI, 210 BAR25 GAL/MIN, 93.75 L/MINStandard (adjustable)10:1N/A
MHC-022-VJSK-00B
Backordered
POR
N/A5000 psiNitrilen/a-34 °C0.38 kgHydraulic Systems DivisionHydraulic Cartridge Systems DivisionExternal45-2000 SSU (6 to 420 cSt)5000 psi93.75 L/minCounterbalance ValveThreaded Cartridge Valve350 barMineral-based or synthetic hydraulic fluids+250 °FAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 4Pilot Operated, Vented25 Gal/min5 @ 80% of setting drops/minCDD-1036Cylinder port 2, Valve port 3, Pilot port 1102-108 NmStandard (adjustable)10:1N/A barN/A barn/aNitrileThreaded Cartridge Valve5000 PSI, 350 BAR25 GAL/MIN, 93.75 L/MINStandard (adjustable)10:1N/A
MHC-022-VJSK-00F
Backordered
POR
N/A5000 psiFluorocarbonn/a-15 °F0.38 kgHydraulic Systems DivisionHydraulic Cartridge Systems DivisionExternal45-2000 SSU (6 to 420 cSt)5000 psi25 Gal/minCounterbalance ValveThreaded Cartridge Valve350 barMineral-based or synthetic hydraulic fluids+400 °FAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 4Pilot Operated, Vented25 Gal/min5 @ 80% of setting drops/minCDD-1036Cylinder port 2, Valve port 3, Pilot port 175-80 lb-ftStandard (adjustable)10:1N/A psiN/A barn/aFluorocarbonThreaded Cartridge Valve5000 PSI, 350 BAR25 GAL/MIN, 93.75 L/MINStandard (adjustable)10:1N/A

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains