Parker's highly versatile 2/2-way seat valves series D4S for subplate mounting are designed for directional control functions and feature numerous options. A large variety of poppets, springs and covers – including shuttle valves, stroke limiters, solenoid valves (VV01) and position control – allows to design individual hydraulic solutions for nominal flow up to 600 l/min.

Markets:
• Industrial

Features/Benefits:
• Proven, robust design - ensures reliable operation
• Individual configurability, various function options - useable for numerous applications
• Good price-performance ratio - fast return of investment
• Short delivery time - no warehousing necessary
• Subplate mounting according to ISO 5781
• Leak-free seat valve design
• Numerous pilot options
• 6 poppet types:
    - D4S03 - NG10
    - D4S06 - NG25
    - D4S10 - NG32

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceDivisionMaximum Operating TemperatureMinimum Operating TemperatureMaximum Operating PressureMounting TypeSeal MaterialFor Fluid TypeBody MaterialProduct SeriesMounting PositionWeightActuation TypeMaximum Flow RateFunctionSeal MaterialCoverOptionsSpool TypeSleeve TypeMinimum Opening PressurePort ConnectionSwitching OptionInput VoltagePilot Inlet / Drain Locations
D4S06-9B134409G0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted4.5 kgPilot360 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRPilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 barNG25 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual override24 (VDC)Pilot line body: External from X (A-X closed / B-Y closed)
D4S06-9B1346B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted4.5 kgPilot360 L/minn/aNBRPilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 2.2 bar, B-A 3.8 barNG25 / ISO 6264N/AnaPilot line body: External from X (A-X closed / B-Y closed)
D4S06-9B13B2B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted4.5 kgPilot180 L/minn/aNBRPilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with throttle spool, 10° chamferAA=0.60 AC, AB=0.40 ACA-B 1 bar, B-A 1.7 barNG25 / ISO 6264N/AnaPilot line body: External from X (A-X closed / B-Y closed)
D4S06-9B13B3B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted4.5 kgPilot360 L/minn/aNBRPilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with throttle spool, 10° chamferAA=0.60 AC, AB=0.40 ACA-B 0.6 BAR, B-A 1.0 BARNG25 / ISO 6264N/AnaPilot line body: External from X (A-X closed / B-Y closed)
D4S06-9B514411G0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted4.5 kgPilot360 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 barNG25 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual override24 (VDC)Pilot line body: External from X (A-X closed / B-Y closed)
D4S06-9B514412G0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted4.5 kgPilot360 L/minVent Function Solenoid activated, unpressurized circulation, without manual override.NBRPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 barNG25 / ISO 6264Vent function: Solenoid activated, unpressurized circulation, without manual override24 (VDC)Pilot line body: External from X (A-X closed / B-Y closed)
D4S06-9B534309G0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted4.5 kgSolenoid360 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 0.6 bar, B-A 0.9 barNG25 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual override24 (VDC)Pilot line body: External from X (A-X closed / B-Y closed)
D4S06-9B534309W30B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted4.5 kgPilot360 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 0.6 BAR, B-A 1.0 BARNG25 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual override110/120 (VAC), 50/60 (Hz)Pilot line body: External from X (A-X closed / B-Y closed)
D4S06-9B534311G0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted4.5 kgPilot360 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 0.6 BAR, B-A 1.0 BARNG25 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual override24 (VDC)Pilot line body: External from X (A-X closed / B-Y closed)
D4S06-9B534409G0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted4.5 kgSolenoid360 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 barNG25 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual override24 (VDC)Pilot line body: External from X (A-X closed / B-Y closed)
D4S06-9B534411G0RB5
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateFPMWater-GlycolCast IronCheck ValveUnrestricted4.5 kgPilot360 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.FPMPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 barNG25 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual override12 (VDC)Pilot line body: External from X (A-X closed / B-Y closed)
D4S06-9B534412W30B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted4.5 kgPilot360 L/minVent Function Solenoid activated, unpressurized circulation, without manual override.NBRPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 barNG25 / ISO 6264Vent function: Solenoid activated, unpressurized circulation, without manual override110/120 (VAC), 50/60 (Hz)Pilot line body: External from X (A-X closed / B-Y closed)
D4S06-9B53C411W30B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted4.5 kgPilot360 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with throttle spool, 3° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 barNG25 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual override110/120 (VAC), 50/60 (Hz)Pilot line body: External from X (A-X closed / B-Y closed)
D4S06-9BC344B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted4.5 kgPilot360 L/minn/aNBRPilot line cap: Standard, pilot oil = pilot drain, X closed, Y open, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 barNG25 / ISO 6264N/AnaPilot line body: External from X (A-X closed / B-Y closed)
D4S06-9C2114CDG0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted2.7 kgPilot360 L/minShuttle Valve X-YNBRPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 barNG25 / ISO 6264Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual override24 (VDC)Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
D4S06-9C2341CDG0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted4.5 kgSolenoid360 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 6.5 bar, B-A 11 barNG25 / ISO 6264Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual override24 (VDC)Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
D4S06-9C2344CDG0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted4.5 kgPilot360 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 barNG25 / ISO 6264Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual override24 (VDC)Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
D4S06-9C2344CDGAGB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted4.5 kgPilot360 L/minShuttle Valve X-YNBRPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 barNG25 / ISO 6264Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual override205 (VDC)Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
D4S06-9C23A4BKG0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted4.5 kgSolenoid360 L/minShuttle Valve X-YNBRPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with safety spoolAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 barNG25 / ISO 6264Shuttle valve X-Y, position control and vent function: Solenoid not activated, unpressurized circulation, without manual override, with amplifier24 (VDC)Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
D4S06-9C23A4BKG0RB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 51524Cast IronCheck ValveUnrestricted4.5 kgPilot360 L/minPosition ControlNBRPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with safety spoolAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 barNG25 / ISO 6264Shuttle valve X-Y, position control and vent function: Solenoid not activated, unpressurized circulation, without manual override, with amplifier12 (VDC)Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)