• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Cover
  • Division
  • For Fluid Type
  • Function
  • Input Voltage
  • Maximum Flow Rate
  • Maximum Operating Pressure
  • Maximum Operating Temperature
More Filters...

2/2-Way Seat Valve for Subplate Mounting - Series D4S

Picture for category 2/2-Way Seat Valve for Subplate Mounting - Series D4S

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's highly versatile 2/2-way seat valves series D4S for subplate mounting are designed for directional control functions and feature numerous options. A large variety of poppets, springs and covers – including shuttle valves, stroke limiters, solenoid valves (VV01) and position control – allows to design individual hydraulic solutions for nominal flow up to 600 l/min.

Markets:
• Industrial

Features/Benefits:
• Proven, robust design - ensures reliable operation
• Individual configurability, various function options - useable for numerous applications
• Good price-performance ratio - fast return of investment
• Short delivery time - no warehousing necessary
• Subplate mounting according to ISO 5781
• Leak-free seat valve design
• Numerous pilot options
• 6 poppet types:
    - D4S03 - NG10
    - D4S06 - NG25
    - D4S10 - NG32

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceDivisionMaximum Operating TemperatureMinimum Operating TemperatureMaximum Operating PressureMounting TypeSeal MaterialFor Fluid TypeWeightBody MaterialProduct SeriesMounting PositionActuation TypeMaximum Flow RateFunctionSeal MaterialOptionsSpool TypeSleeve TypePort ConnectionPilot Inlet / Drain LocationsMinimum Opening PressureSwitching OptionCoverInput Voltage
D4S03-9D2344CBG0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedPilot180 L/minShuttle Valve X-YNBRN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACNG10 / ISO 6264Pilot line body: Internal from B (A-X closed / B-Y orifice 1.2)A-B 4.0 bar, B-A 5.5 barShuttle valve X-Y and vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed24 (VDC)
D4S03-9D2344CDG0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedPilot180 L/minShuttle Valve X-YNBRN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACNG10 / ISO 6264Pilot line body: Internal from B (A-X closed / B-Y orifice 1.2)A-B 4.0 bar, B-A 5.5 barShuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed24 (VDC)
D4S03-9DC114B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedPilot180 L/minn/aNBRN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACNG10 / ISO 6264Pilot line body: Internal from B (A-X closed / B-Y orifice 1.2)A-B 2.2 barN/APilot line cap: Standard, pilot oil = pilot drain, X closed, Y open, Z orifice 1.2, X-Y open, Y1 closedna
D4S03-9G1116B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedSolenoid180 L/minn/aNBRN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACNG10 / ISO 6264Pilot line body: External from Y (A-X orifice 1.2 / B-Y open)A-B 1.2 barN/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedna
D4S06-911112B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515244.5 kgCast IronCheck ValveUnrestrictedPilot360 L/minn/aNBRN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACNG25 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open)A-B 0.5 barN/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedna
D4S06-911144B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515244.5 kgCast IronCheck ValveUnrestrictedSolenoid360 L/minn/aNBRN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACNG25 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open)A-B 2.2 barN/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedna
D4S06-9123A4BEG0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515244.5 kgCast IronCheck ValveUnrestrictedPilot360 L/minPosition Control and Vent Function Solenoid activated, unpressurized circulation, without manual override, with amplifier.NBRN/APoppet with safety spoolAA=0.60 AC, AB=0.40 ACNG25 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open)A-B 3.5 bar, B-A 6.0 barPosition control and vent function: Solenoid activated, unpressurized circulation, without manual override, with amplifierPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed24 (VDC)
D4S06-91611211G0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515244.5 kgCast IronCheck ValveUnrestrictedSolenoid360 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACNG25 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open)A-B 0.5 barVent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open24 (VDC)
D4S06-91614211W30B1
Backordered
POR
Hydraulic Valve Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515244.5 kgCast IronCheck ValveUnrestrictedSolenoid180 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRNAPoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACNG25 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open)A-B 0.5 barVent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open110/120 (VAC), 50/60 (Hz)
D4S06-91614409G0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515244.5 kgCast IronCheck ValveUnrestrictedPilot360 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACNG25 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open)A-B 2.2 barVent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open24 (VDC)
D4S06-91634409G0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515244.5 kgCast IronCheck ValveUnrestrictedSolenoid360 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACNG25 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open)A-B 3.5 bar, B-A 6.0 barVent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open24 (VDC)
D4S06-921113B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515244.5 kgCast IronCheck ValveUnrestrictedPilot180 L/minn/aNBRN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACNG25 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)A-B 0.3 barN/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedna
D4S06-921114B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515244.5 kgCast IronCheck ValveUnrestrictedPilot360 L/minn/aNBRN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACNG25 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)A-B 2.2 barN/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedna
D4S06-921343B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515244.5 kgCast IronCheck ValveUnrestrictedPilot360 L/minn/aNBRN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACNG25 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)A-B 0.6 BAR, B-A 1.0 BARN/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedna
D4S06-9213A3BAB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515244.5 kgCast IronCheck ValveUnrestrictedPilot360 L/minPosition Control with amplifierNBRN/APoppet with safety spoolAA=0.60 AC, AB=0.40 ACNG25 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)A-B 0.6 BAR, B-A 1.0 BARPosition control, with amplifierPilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedna
D4S06-92214111W30B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515244.5 kgCast IronCheck ValveUnrestrictedPilot360 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACNG25 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)A-B 3.5 BARVent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed110/120 (VAC), 50/60 (Hz)
D4S06-92214311G0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515244.5 kgCast IronCheck ValveUnrestrictedSolenoid360 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACNG25 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)A-B 0.3 barVent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed24 (VDC)
D4S06-92234411W30B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515244.5 kgCast IronCheck ValveUnrestrictedPilot360 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACNG25 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)A-B 3.5 bar, B-A 6.0 barVent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed110/120 (VAC), 50/60 (Hz)
D4S06-9223A4BEW30B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515244.5 kgCast IronCheck ValveUnrestrictedSolenoid360 L/minPosition Control and Vent Function Solenoid activated, unpressurized circulation, without manual override, with amplifier.NBRN/APoppet with safety spoolAA=0.60 AC, AB=0.40 ACNG25 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)A-B 3.5 bar, B-A 6.0 barPosition control and vent function: Solenoid activated, unpressurized circulation, without manual override, with amplifierPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed110/120 (VAC), 50/60 (Hz)
D4S06-923112B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515244.5 kgCast IronCheck ValveUnrestrictedPilot360 L/minn/aNBRN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACNG25 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)A-B 0.5 barN/APilot line cap: With stroke limiter, pilot oil = pilot drain, X orifice 1.2, Y closedna

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains