• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Cover
  • Division
  • For Fluid Type
  • Function
  • Input Voltage
  • Maximum Flow Rate
  • Maximum Operating Pressure
  • Maximum Operating Temperature
More Filters...

2/2-Way Seat Valve for Subplate Mounting - Series D4S

Picture for category 2/2-Way Seat Valve for Subplate Mounting - Series D4S

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's highly versatile 2/2-way seat valves series D4S for subplate mounting are designed for directional control functions and feature numerous options. A large variety of poppets, springs and covers – including shuttle valves, stroke limiters, solenoid valves (VV01) and position control – allows to design individual hydraulic solutions for nominal flow up to 600 l/min.

Markets:
• Industrial

Features/Benefits:
• Proven, robust design - ensures reliable operation
• Individual configurability, various function options - useable for numerous applications
• Good price-performance ratio - fast return of investment
• Short delivery time - no warehousing necessary
• Subplate mounting according to ISO 5781
• Leak-free seat valve design
• Numerous pilot options
• 6 poppet types:
    - D4S03 - NG10
    - D4S06 - NG25
    - D4S10 - NG32

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceMaximum Operating TemperatureFunctionWeightBody MaterialDivisionSeal MaterialMaximum Flow RateMaximum Operating PressureActuation TypeMounting TypeProduct SeriesMinimum Operating TemperatureMounting PositionFor Fluid TypePilot Inlet / Drain LocationsSwitching OptionCoverOptionsSleeve TypeSeal MaterialPort ConnectionInput VoltageMinimum Opening PressureSpool Type
D4S06-9233C3B1
Backordered
POR
60 °Cn/a4.5 kgCast IronHydraulic Valve Systems Division EuropeNBR180 L/min350 barPilotSubplateCheck Valve-20 °CUnrestrictedHydraulic Oil According to DIN 51524Pilot line body: External from X (A-X closed / B-Y open)naPilot line cap: With stroke limiter, pilot oil = pilot drain, X orifice 1.2, Y closedNAAA=0.60 AC, AB=0.40 ACNBRNG25 / ISO 6264naA-B 0.6 BAR, B-A 1.0 BARPoppet with throttle spool, 3° chamfer
D4S06-924342B1
Backordered
POR
60 °Cn/a4.5 kgCast IronIndustrial Systems Division EuropeNBR360 L/min350 barSolenoidSubplateCheck Valve-20 °CUnrestrictedHydraulic Oil According to DIN 51524Pilot line body: External from X (A-X closed / B-Y open)N/APilot line cap: With stroke limiter, pilot oil = pilot drain, X closed, Y orifice 1.2N/AAA=0.60 AC, AB=0.40 ACNBRNG25 / ISO 6264naA-B 1 bar, B-A 1.7 barPoppet with closed bottom, 45° chamfer
D4S06-92614311GADB5
Backordered
POR
60 °CVent Function Solenoid activated, unpressurized circulation, with manual override.4.5 kgCast IronIndustrial Systems Division EuropeFPM360 L/min350 barPilotSubplateCheck Valve-20 °CUnrestrictedWater-GlycolPilot line body: External from X (A-X closed / B-Y open)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/AAA=0.95 AC, AB=0.05 ACFPMNG25 / ISO 6264naA-B 0.3 barPoppet with closed bottom, 45° chamfer
D4S06-92C115B1
Backordered
POR
60 °Cn/a4.5 kgCast IronIndustrial Systems Division EuropeNBR360 L/min350 barSolenoidSubplateCheck Valve-20 °CUnrestrictedHydraulic Oil According to DIN 51524Pilot line body: External from X (A-X closed / B-Y open)N/APilot line cap: Standard, pilot oil = pilot drain, X closed, Y open, Z orifice 1.2, X-Y open, Y1 closedN/AAA=0.95 AC, AB=0.05 ACNBRNG25 / ISO 6264naA-B 9.0 barPoppet with closed bottom, 15° chamfer
D4S06-9A1114B1
Backordered
POR
60 °Cn/a4.5 kgCast IronIndustrial Systems Division EuropeNBR360 L/min350 barPilotSubplateCheck Valve-20 °CUnrestrictedHydraulic Oil According to DIN 51524Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/AAA=0.95 AC, AB=0.05 ACNBRNG25 / ISO 6264naA-B 2.2 barPoppet with closed bottom, 15° chamfer
D4S06-9A511111G0QB1
Backordered
POR
60 °CVent Function Solenoid activated, unpressurized circulation, with manual override.4.5 kgCast IronIndustrial Systems Division EuropeNBR360 L/min350 barSolenoidSubplateCheck Valve-20 °CUnrestrictedHydraulic Oil According to DIN 51524Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/AAA=0.95 AC, AB=0.05 ACNBRNG25 / ISO 626424 (VDC)A-B 3.5 BARPoppet with closed bottom, 15° chamfer
D4S06-9A511410G0QB5
Backordered
POR
60 °CVent Function Solenoid not activated, unpressurized circulation, without manual override.4.5 kgCast IronIndustrial Systems Division EuropeFPM360 L/min350 barSolenoidSubplateCheck Valve-20 °CUnrestrictedWater-GlycolPilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Vent function: solenoid not activated, unpressurized circulation, without manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/AAA=0.95 AC, AB=0.05 ACFPMNG25 / ISO 626424 (VDC)A-B 2.2 barPoppet with closed bottom, 15° chamfer
D4S06-9A511411G0QB1
Backordered
POR
60 °CVent Function Solenoid activated, unpressurized circulation, with manual override.4.5 kgCast IronIndustrial Systems Division EuropeNBR360 L/min350 barSolenoidSubplateCheck Valve-20 °CUnrestrictedHydraulic Oil According to DIN 51524Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/AAA=0.95 AC, AB=0.05 ACNBRNG25 / ISO 626424 (VDC)A-B 2.2 barPoppet with closed bottom, 15° chamfer
D4S06-9A514411G0QB1
Backordered
POR
60 °CVent Function Solenoid activated, unpressurized circulation, with manual override.4.5 kgCast IronIndustrial Systems Division EuropeNBR360 L/min350 barPilotSubplateCheck Valve-20 °CUnrestrictedHydraulic Oil According to DIN 51524Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/AAA=0.95 AC, AB=0.05 ACNBRNG25 / ISO 626424 (VDC)A-B 2.2 barPoppet with closed bottom, 45° chamfer
D4S06-9A514412G0QB1
Backordered
POR
60 °CVent Function Solenoid activated, unpressurized circulation, without manual override.4.5 kgCast IronIndustrial Systems Division EuropeNBR360 L/min350 barPilotSubplateCheck Valve-20 °CUnrestrictedHydraulic Oil According to DIN 51524Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Vent function: Solenoid activated, unpressurized circulation, without manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/AAA=0.95 AC, AB=0.05 ACNBRNG25 / ISO 626424 (VDC)A-B 2.2 barPoppet with closed bottom, 45° chamfer
D4S06-9A514412G0QB5
Backordered
POR
60 °CVent Function Solenoid activated, unpressurized circulation, without manual override.4.5 kgCast IronIndustrial Systems Division EuropeFPM360 L/min350 barPilotSubplateCheck Valve-20 °CUnrestrictedWater-GlycolPilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Vent function: Solenoid activated, unpressurized circulation, without manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/AAA=0.95 AC, AB=0.05 ACFPMNG25 / ISO 626424 (VDC)A-B 2.2 barPoppet with closed bottom, 45° chamfer
D4S06-9A514609W30B1
Backordered
POR
60 °CVent Function Solenoid not activated, unpressurized circulation, with manual override.4.5 kgCast IronIndustrial Systems Division EuropeNBR360 L/min350 barPilotSubplateCheck Valve-20 °CUnrestrictedHydraulic Oil According to DIN 51524Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/AAA=0.95 AC, AB=0.05 ACNBRNG25 / ISO 6264110/120 (VAC), 50/60 (Hz)A-B 1.2 barPoppet with closed bottom, 45° chamfer
D4S06-9A514612W30B1
Backordered
POR
60 °CVent Function Solenoid activated, unpressurized circulation, without manual override.4.5 kgCast IronIndustrial Systems Division EuropeNBR360 L/min350 barPilotSubplateCheck Valve-20 °CUnrestrictedHydraulic Oil According to DIN 51524Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Vent function: Solenoid activated, unpressurized circulation, without manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/AAA=0.95 AC, AB=0.05 ACNBRNG25 / ISO 6264110/120 (VAC), 50/60 (Hz)A-B 1.2 barPoppet with closed bottom, 45° chamfer
D4S06-9A534111W30B1
Backordered
POR
60 °CVent Function Solenoid activated, unpressurized circulation, with manual override.4.5 kgCast IronIndustrial Systems Division EuropeNBR360 L/min350 barPilotSubplateCheck Valve-20 °CUnrestrictedHydraulic Oil According to DIN 51524Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/AAA=0.60 AC, AB=0.40 ACNBRNG25 / ISO 6264110/120 (VAC), 50/60 (Hz)A-B 6.5 bar, B-A 11 barPoppet with closed bottom, 45° chamfer
D4S06-9A534410W30B1
Backordered
POR
60 °CVent Function Solenoid not activated, unpressurized circulation, without manual override.4.5 kgCast IronHydraulic Valve Systems Division EuropeNBR180 L/min350 barPilotSubplateCheck Valve-20 °CUnrestrictedHydraulic Oil According to DIN 51524Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Vent function: solenoid not activated, unpressurized circulation, without manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openNAAA=0.60 AC, AB=0.40 ACNBRNG25 / ISO 6264naA-B 3.5 bar, B-A 6.0 barPoppet with closed bottom, 45° chamfer
D4S06-9A534511G0QB1
Backordered
POR
60 °CVent Function Solenoid activated, unpressurized circulation, with manual override.4.5 kgCast IronIndustrial Systems Division EuropeNBR360 L/min350 barPilotSubplateCheck Valve-20 °CUnrestrictedHydraulic Oil According to DIN 51524Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/AAA=0.60 AC, AB=0.40 ACNBRNG25 / ISO 626424 (VDC)A-B 16.0 bar, B-A 28.0 barPoppet with closed bottom, 45° chamfer
D4S06-9A53A4BCG0QB1
Backordered
POR
60 °CPosition Control and Vent Function Solenoid activated, unpressurized circulation, without manual override, with amplifier.4.5 kgCast IronIndustrial Systems Division EuropeNBR360 L/min350 barPilotSubplateCheck Valve-20 °CUnrestrictedHydraulic Oil According to DIN 51524Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Position control and vent function: Solenoid not activated, unpressurized circulation, without manual override, with amplifierPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/AAA=0.60 AC, AB=0.40 ACNBRNG25 / ISO 626424 (VDC)A-B 3.5 bar, B-A 6.0 barPoppet with safety spool
D4S06-9A53A4BEG0QB1
Backordered
POR
60 °CPosition Control and Vent Function Solenoid activated, unpressurized circulation, without manual override, with amplifier.4.5 kgCast IronIndustrial Systems Division EuropeNBR360 L/min350 barPilotSubplateCheck Valve-20 °CUnrestrictedHydraulic Oil According to DIN 51524Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Position control and vent function: Solenoid activated, unpressurized circulation, without manual override, with amplifierPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/AAA=0.60 AC, AB=0.40 ACNBRNG25 / ISO 626424 (VDC)A-B 3.5 bar, B-A 6.0 barPoppet with safety spool
D4S06-9A53B209G0QB1
Backordered
POR
60 °CVent Function Solenoid not activated, unpressurized circulation, with manual override.4.5 kgCast IronIndustrial Systems Division EuropeNBR360 L/min350 barSolenoidSubplateCheck Valve-20 °CUnrestrictedHydraulic Oil According to DIN 51524Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/AAA=0.60 AC, AB=0.40 ACNBRNG25 / ISO 626424 (VDC)A-B 1 bar, B-A 1.7 barPoppet with throttle spool, 10° chamfer
D4S06-9B1116B1
Backordered
POR
60 °Cn/a4.5 kgCast IronIndustrial Systems Division EuropeNBR360 L/min350 barPilotSubplateCheck Valve-20 °CUnrestrictedHydraulic Oil According to DIN 51524Pilot line body: External from X (A-X closed / B-Y closed)N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/AAA=0.95 AC, AB=0.05 ACNBRNG25 / ISO 6264naA-B 1.2 barPoppet with closed bottom, 15° chamfer

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains