*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The directional control valve series D1VW in NG06 (CETOP 03 / NFPA D03) provides high functional limits up to 80 l/min in combination with a very low, energy-saving pressure drop due to optimized flow passages. The maximum pressure is 350 bar.

A wide variety of spools and options allows to design an unlimited number of hydraulic circuits. The D1VW is available with a soft shift option for smooth operation. An additional orifice in the solenoid anchor dampens the shifting time.

Markets:
• Industrial

Features/Benefits:
• Compact, proven design that represents our long-term experience in hydraulics
• Wide range of spools - fits all hydraulic systems
• Shortest lead time - no warehousing necessary
• Optional soft shift option - for smooth operation
• Optional manual override

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceInterface TypeBody MaterialMinimum Operating TemperatureSolenoid OptionDivisionMaximum Flow RateProduct TypeMaximum Operating PressureWeightSizeMaximum Operating TemperatureIngress Protection RatingActuation TypeInput VoltageMaterial - SealsConnection TypeSpool PositionSpool CodeProduct Series
D1VW006CVJWXC005
Backordered
POR
ISO 4401Gray Iron-25 °COmit - Manual Override (standard)Control Division China80 L/min (depending on spoolDirectional Spool ValveT: 210 bar2.1 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid24 VDCV - FKMConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b006XC005
D1VW006ENJWXC005
Backordered
POR
CETOP RP 121-HGray Iron-25 °COmit - Manual Override (standard)Control Division China80 L/min (depending on spoolDirectional Spool ValveP, A, B: 350 bar1.5 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid24 VDCN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a006XC005
D1VW006ENKWXC005
Backordered
POR
DIN 24340 A6Gray Iron-25 °COmit - Manual Override (standard)Control Division China80 L/min (depending on spoolDirectional Spool ValveP, A, B: 350 bar1.5 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid12 VDCN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a006XC005
D1VW006KNJWXC005
Backordered
POR
DIN 24340 A6Gray Iron-25 °COmit - Manual Override (standard)Control Division China80 L/min (depending on spoolDirectional Spool ValveP, A, B: 350 bar1.5 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid24 VDCN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)K - 2 positions, spring offset in position 0, operated in position b006XC005
D1VW006KNKWXC005
Backordered
POR
DIN 24340 A6Gray Iron-25 °COmit - Manual Override (standard)Control Division Chinasee shift limits) L/min (depending on spoolDirectional Spool ValveT: 210 bar1.5 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid12 VDCN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)K - 2 positions, spring offset in position 0, operated in position b006XC005
D1VW008CVJWXC005
Backordered
POR
DIN 24340 A6Gray Iron-25 °COmit - Manual Override (standard)Control Division China80 L/min (depending on spoolDirectional Spool ValveT: 210 bar2.1 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid24 VDCV - FKMConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b008XC005
D1VW008ENKWXC005
Backordered
POR
ISO 4401Gray Iron-25 °COmit - Manual Override (standard)Control Division China80 L/min (depending on spoolDirectional Spool ValveT: 210 bar1.5 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid12 VDCN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a008XC005
D1VW008EVJWXC005
Backordered
POR
ISO 4401Gray Iron-25 °COmit - Manual Override (standard)Control Division Chinasee shift limits) L/min (depending on spoolDirectional Spool ValveT: 210 bar1.5 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid24 VDCV - FKMConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a008XC005
D1VW008KNJWXC005
Backordered
POR
ISO 4401Gray Iron-25 °COmit - Manual Override (standard)Control Division China80 L/min (depending on spoolDirectional Spool ValveP, A, B: 350 bar1.5 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid24 VDCN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)K - 2 positions, spring offset in position 0, operated in position b008XC005
D1VW009CNJWXC005
Backordered
POR
ISO 4401Gray Iron-25 °COmit - Manual Override (standard)Control Division China80 L/min (depending on spoolDirectional Spool ValveP, A, B: 350 bar2.1 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid24 VDCN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b009XC005
D1VW009CVJWXC005
Backordered
POR
DIN 24340 A6Gray Iron-25 °COmit - Manual Override (standard)Control Division Chinasee shift limits) L/min (depending on spoolDirectional Spool ValveP, A, B: 350 bar2.1 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid24 VDCV - FKMConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b009XC005
D1VW009ENJWXC005
Backordered
POR
DIN 24340 A6Gray Iron-25 °COmit - Manual Override (standard)Control Division Chinasee shift limits) L/min (depending on spoolDirectional Spool ValveT: 210 bar1.5 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid24 VDCN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a009XC005
D1VW009ENKWXC005
Backordered
POR
CETOP RP 121-HGray Iron-25 °COmit - Manual Override (standard)Control Division China80 L/min (depending on spoolDirectional Spool ValveP, A, B: 350 bar1.5 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid12 VDCN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a009XC005
D1VW009EVJWXC005
Backordered
POR
CETOP RP 121-HGray Iron-25 °COmit - Manual Override (standard)Control Division China80 L/min (depending on spoolDirectional Spool ValveT: 210 bar1.5 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid24 VDCV - FKMConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)E - 2 positions, spring offset in position 0, operated in position a009XC005
D1VW009KNJWXC005
Backordered
POR
NFPA D03Gray Iron-25 °COmit - Manual Override (standard)Control Division China80 L/min (depending on spoolDirectional Spool ValveP, A, B: 350 bar1.5 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid24 VDCN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)K - 2 positions, spring offset in position 0, operated in position b009XC005
D1VW011CNJWXC005
Backordered
POR
NFPA D03Gray Iron-25 °COmit - Manual Override (standard)Control Division Chinasee shift limits) L/min (depending on spoolDirectional Spool ValveT: 210 bar2.1 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid24 VDCN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b011XC005
D1VW011CNKWXC005
Backordered
POR
DIN 24340 A6Gray Iron-25 °COmit - Manual Override (standard)Control Division China80 L/min (depending on spoolDirectional Spool ValveP, A, B: 350 bar2.1 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid12 VDCN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b011XC005
D1VW011CVJWXC005
Backordered
POR
DIN 24340 A6Gray Iron-25 °COmit - Manual Override (standard)Control Division Chinasee shift limits) L/min (depending on spoolDirectional Spool ValveT: 210 bar2.1 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid24 VDCV - FKMConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b011XC005
D1VW014CNJWXC005
Backordered
POR
NFPA D03Gray Iron-25 °COmit - Manual Override (standard)Control Division China80 L/min (depending on spoolDirectional Spool ValveP, A, B: 350 bar2.1 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid24 VDCN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b014XC005
D1VW015CNJWXC005
Backordered
POR
CETOP RP 121-HGray Iron-25 °COmit - Manual Override (standard)Control Division China80 L/min (depending on spoolDirectional Spool ValveP, A, B: 350 bar2.1 kgDIN NG06 / CETOP 03 / NFPA D03 nom60 °CIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)Solenoid24 VDCN - NBRConnector as per EN 175301-803, solenoid identification as per ISO 9461 (code W)C - 3 positions, spring offset in position 0, operated in position a or b015XC005

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains