• Availability & Price
  • Search SKU
Filter by attributes
  • Application
  • Brand
  • Compatible Element
  • Connection Type
  • Depth
  • Division
  • Division
  • Drain
  • Element Change Interval
  • Filter Stages
More Filters...

OIL-X 'Point Of Use' Oil Vapour Reduction Filters

Picture for category OIL-X 'Point Of Use' Oil Vapour Reduction Filters

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Oil vapour is oil in a gaseous form and will pass straight through coalescing filters which are designed to remove liquid oil and oil aerosols, Parker recommend activated carbon adsorption filter technology to reduce oil vapour.

OIL-X 'point of use' oil vapour reduction filters are available in two options: the Grade ACS single stage adsorption filter and Grade AC double stage filter - Grade AC consists of both coalescing and adsorption filter elements combined into one housing. OIL-X Grades ACS and AC are used for smaller flow rate applications and applications where more frequent element changes can be tolerated.

Features/Benefits
• High efficiency 'point of use' filters
• Protects downstream equipment and processes
• Provides high quality, clean, oil free compressed air to international standards
• Reduced cost of ownership
• Enhanced health and safety
• Suitable for all types of air compressor and compatible with all compressor lubricants
• Manufactured in accordance with ISO9001

Sizing and Selection
Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

Please note: The lifetime of the activated carbon material can vary and is dependent on the contamination type and quantity and also on the humidity of the compressed air.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceBrandTechnologyDivisionIndustryApplicationDivisionMicron RatingProduct TypeDepthMaterials of ConstructionProduct SeriesOperating PressureSpecifications MetResidual Oil ContentOperating TemperaturePressure DifferentialFilter TypeWidthHeightWeightCompatible ElementElement Change IntervalConnection TypePort SizeDrainFilter StagesMaximum Flow Rate
AC020CGFI
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter84.0 mmDie Cast AluminiumOIL-X Grades ACS and AC1 to 16 bargFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)35 to 86 °F11 psi Initial Dry, 100% FlowOil Vapour Reduction97.0 mm18.7 inch3.2 lbP020AA and 020AC<br/>Requires BothP020AA:<br/> 12 Months<br/><br/>020AC:<br/> When oil vapour is detectedBSPP½ inchAutomatic FloatDouble Stage90 m³/h @ 7 barg (53 cfm @ 102 psig)
AC020CGFX
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter84.0 mmDie Cast AluminiumOIL-X Grades ACS and AC15 to 232 psigFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)35 to 86 °F11 psi Initial Dry, 100% FlowOil Vapour Reduction3.8 inch18.7 inch3.2 lbP020AA and 020AC<br/>Requires BothP020AA:<br/> 12 Months<br/><br/>020AC:<br/> When oil vapour is detectedBSPP½ inchAutomatic FloatDouble Stage90 m³/h @ 7 barg (53 cfm @ 102 psig)
AC020CGMI
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter3.3 inchDie Cast AluminiumOIL-X Grades ACS and AC15 to 290 psigFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)35 to 86 °F11 psi Initial Dry, 100% FlowOil Vapour Reduction3.8 inch18.7 inch1.4 kgP020AA and 020AC<br/>Requires BothP020AA:<br/> 12 Months<br/><br/>020AC:<br/> When oil vapour is detectedBSPP½ inchManualDouble Stage90 m³/h @ 7 barg (53 cfm @ 102 psig)
AC020CNFI
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter84.0 mmDie Cast AluminiumOIL-X Grades ACS and AC1 to 16 bargFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)2 to 30 °C< 773 mbar Initial Dry, 100% FlowOil Vapour Reduction97.0 mm474.0 mm1.4 kgP020AA and 020AC<br/>Requires BothP020AA:<br/> 12 Months<br/><br/>020AC:<br/> When oil vapour is detectedNPT½ inchAutomatic FloatDouble Stage90 m³/h @ 7 barg (53 cfm @ 102 psig)
AC020DGFI
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter3.3 inchDie Cast AluminiumOIL-X Grades ACS and AC1 to 16 bargFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)2 to 30 °C11 psi Initial Saturated, 100% FlowOil Vapour Reduction97.0 mm18.7 inch1.4 kgP020AA and 020AC<br/>Requires BothP020AA:<br/> 12 Months<br/><br/>020AC:<br/> When oil vapour is detectedBSPP½ inchAutomatic FloatDouble Stage90 m³/h @ 7 barg (53 cfm @ 102 psig)
AC020DGFX
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter3.3 inchDie Cast AluminiumOIL-X Grades ACS and AC1 to 16 bargFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)35 to 86 °F11 psi Initial Dry, 100% FlowOil Vapour Reduction97.0 mm18.7 inch3.2 lbP020AA and 020AC<br/>Requires BothP020AA:<br/> 12 Months<br/><br/>020AC:<br/> When oil vapour is detectedBSPP¾ inchAutomatic FloatDouble Stage90 m³/h @ 7 barg (53 cfm @ 102 psig)
AC020DNFI
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter84.0 mmDie Cast AluminiumOIL-X Grades ACS and AC15 to 232 psigFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)2 to 30 °C< 773 mbar Initial Dry, 100% FlowOil Vapour Reduction97.0 mm18.7 inch3.2 lbP020AA and 020AC<br/>Requires BothP020AA:<br/> 12 Months<br/><br/>020AC:<br/> When oil vapour is detectedNPT¾ inchAutomatic FloatDouble Stage90 m³/h @ 7 barg (53 cfm @ 102 psig)
AC020EGFI
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter3.3 inchDie Cast AluminiumOIL-X Grades ACS and AC15 to 232 psigFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)35 to 86 °F11 psi Initial Dry, 100% FlowOil Vapour Reduction3.8 inch18.7 inch3.2 lbP020AA and 020AC<br/>Requires BothP020AA:<br/> 12 Months<br/><br/>020AC:<br/> When oil vapour is detectedBSPP1 inchAutomatic FloatDouble Stage90 m³/h @ 7 barg (53 cfm @ 102 psig)
AC020EGFX
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter3.3 inchDie Cast AluminiumOIL-X Grades ACS and AC15 to 232 psigFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)35 to 86 °F< 773 mbar Initial Dry, 100% FlowOil Vapour Reduction3.8 inch474.0 mm1.4 kgP020AA and 020AC<br/>Requires BothP020AA:<br/> 12 Months<br/><br/>020AC:<br/> When oil vapour is detectedBSPP1 inchAutomatic FloatDouble Stage90 m³/h @ 7 barg (53 cfm @ 102 psig)
AC020EGMI
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter3.3 inchDie Cast AluminiumOIL-X Grades ACS and AC1 to 20 bargFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)2 to 30 °C11 psi Initial Dry, 100% FlowOil Vapour Reduction97.0 mm18.7 inch3.2 lbP020AA and 020AC<br/>Requires BothP020AA:<br/> 12 Months<br/><br/>020AC:<br/> When oil vapour is detectedBSPP1 inchManualDouble Stage90 m³/h @ 7 barg (53 cfm @ 102 psig)
AC020ENFI
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter3.3 inchDie Cast AluminiumOIL-X Grades ACS and AC1 to 16 bargFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)2 to 30 °C11 psi Initial Dry, 100% FlowOil Vapour Reduction3.8 inch18.7 inch3.2 lbP020AA and 020AC<br/>Requires BothP020AA:<br/> 12 Months<br/><br/>020AC:<br/> When oil vapour is detectedNPT1 inchAutomatic FloatDouble Stage90 m³/h @ 7 barg (53 cfm @ 102 psig)
AC025DGFI
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter4.5 inchDie Cast AluminiumOIL-X Grades ACS and AC1 to 16 bargFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)2 to 30 °C< 773 mbar Initial Dry, 100% FlowOil Vapour Reduction129.0 mm554.0 mm3.5 kgP025AA and 025DAC<br/>Requires BothP025AA:<br/> 12 Months<br/><br/>025DAC:<br/> When oil vapour is detectedBSPP¾ inchManualDouble Stage90 m³/h @ 7 barg (53 cfm @ 102 psig)
AC025DGFX
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter4.5 inchDie Cast AluminiumOIL-X Grades ACS and AC15 to 232 psigFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)2 to 30 °C< 773 mbar Initial Dry, 100% FlowOil Vapour Reduction129.0 mm554.0 mm7.8 lbP025AA and 025DAC<br/>Requires BothP025AA:<br/> 12 Months<br/><br/>025DAC:<br/> When oil vapour is detectedBSPP¾ inchAutomatic FloatDouble Stage90 m³/h @ 7 barg (53 cfm @ 102 psig)
AC025DNFI
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter115.0 mmDie Cast AluminiumOIL-X Grades ACS and AC1 to 16 bargFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)35 to 86 °F11 psi Initial Dry, 100% FlowOil Vapour Reduction5.1 inch21.8 inch3.5 kgP025AA and 025DAC<br/>Requires BothP025AA:<br/> 12 Months<br/><br/>025DAC:<br/> When oil vapour is detectedNPT¾ inchAutomatic FloatDouble Stage143 m³/h @ 7 barg (84 cfm @ 102 psig)
AC025EGFI
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter4.5 inchDie Cast AluminiumOIL-X Grades ACS and AC15 to 232 psigFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)2 to 30 °C11 psi Initial Dry, 100% FlowOil Vapour Reduction5.1 inch21.8 inch7.6 lbP025AA and 025EAC<br/>Requires BothP025AA:<br/> 12 Months<br/><br/>025EAC:<br/> When oil vapour is detectedBSPP1 inchAutomatic FloatDouble Stage143 m³/h @ 7 barg (84 cfm @ 102 psig)
AC025EGFX
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter4.5 inchDie Cast AluminiumOIL-X Grades ACS and AC1 to 16 bargFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)2 to 30 °C11 psi Initial Dry, 100% FlowOil Vapour Reduction129.0 mm21.8 inch7.6 lbP025AA and 025EAC<br/>Requires BothP025AA:<br/> 12 Months<br/><br/>025EAC:<br/> When oil vapour is detectedBSPP1 inchAutomatic FloatDouble Stage143 m³/h @ 7 barg (84 cfm @ 102 psig)
AC025EGMI
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter115.0 mmDie Cast AluminiumOIL-X Grades ACS and AC1 to 20 bargFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)2 to 30 °C< 773 mbar Initial Dry, 100% FlowOil Vapour Reduction129.0 mm21.8 inch7.6 lbP025AA and 025EAC<br/>Requires BothP025AA:<br/> 12 Months<br/><br/>025EAC:<br/> When oil vapour is detectedBSPP1 inchManualDouble Stage231 m³/h @ 7 barg (136 cfm @ 102 psig)
AC025ENFI
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter4.5 inchDie Cast AluminiumOIL-X Grades ACS and AC15 to 232 psigFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)35 to 86 °F11 psi Initial Dry, 100% FlowOil Vapour Reduction5.1 inch554.0 mm7.6 lbP025AA and 025EAC<br/>Requires BothP025AA:<br/> 12 Months<br/><br/>025EAC:<br/> When oil vapour is detectedNPT1 inchAutomatic FloatDouble Stage231 m³/h @ 7 barg (136 cfm @ 102 psig)
AC030EGMI
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter115.0 mmDie Cast AluminiumOIL-X Grades ACS and AC15 to 290 psigFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)2 to 30 °C< 773 mbar Initial Dry, 100% FlowOil Vapour Reduction5.1 inch733.0 mm9 lbP030AA and 030AC<br/>Requires BothP030AA:<br/> 12 Months<br/><br/>030AC:<br/> When oil vapour is detectedBSPP1 inchManualDouble Stage305 m³/h @ 7 barg (180 cfm @ 102 psig)
AC030ENFI
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAdown to 0.01 MICRONCompressed Air Filter115.0 mmDie Cast AluminiumOIL-X Grades ACS and AC15 to 232 psigFully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group IIAerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)35 to 86 °F< 773 mbar Initial Dry, 100% FlowOil Vapour Reduction129.0 mm28.9 inch9 lbP030AA and 030AC<br/>Requires Both030AA:<br/> 12 Months<br/><br/>030AC:<br/> When oil vapour is detectedNPT1 inchAutomatic FloatDouble Stage305 m³/h @ 7 barg (180 cfm @ 102 psig)

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains