*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Action | SKU | Availability | Price | Brand | Technology | Division | Industry | Application | Division | Weight | Depth | Micron Rating | Product Type | Materials of Construction | Product Series | Operating Pressure | Specifications Met | Residual Oil Content | Operating Temperature | Pressure Differential | Filter Type | Width | Height | Compatible Element | Element Change Interval | Connection Type | Drain | Filter Stages | Port Size | Maximum Flow Rate |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AC030FGFI | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 4.1 kg | 4.5 inch | down to 0.01 MICRON | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 15 to 232 psig | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 2 to 30 °C | 11 psi Initial Dry, 100% Flow | Oil Vapour Reduction | 129.0 mm | 28.9 inch | P030AA and 030AC<br/>Requires Both | 030AA:<br/> 12 Months<br/><br/>030AC:<br/> When oil vapour is detected | BSPP | Automatic Float | Double Stage | 1¼ inch | 305 m³/h @ 7 barg (180 cfm @ 102 psig) | |
AC030FGFX | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 9 lb | 4.5 inch | down to 0.01 MICRON | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 1 to 16 barg | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 35 to 86 °F | 11 psi Initial Dry, 100% Flow | Oil Vapour Reduction | 5.1 inch | 733.0 mm | P030AA and 030AC<br/>Requires Both | 030AA:<br/> 12 Months<br/><br/>030AC:<br/> When oil vapour is detected | BSPP | Automatic Float | Double Stage | 1¼ inch | 305 m³/h @ 7 barg (180 cfm @ 102 psig) | |
AC030GGFI | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 9 lb | 4.5 inch | down to 0.01 MICRON | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 15 to 232 psig | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 2 to 30 °C | 11 psi Initial Dry, 100% Flow | Oil Vapour Reduction | 129.0 mm | 733.0 mm | P030AA and 030AC<br/>Requires Both | 030AA:<br/> 12 Months<br/><br/>030AC:<br/> When oil vapour is detected | BSPP | Automatic Float | Double Stage | 1½ inch | 305 m³/h @ 7 barg (180 cfm @ 102 psig) | |
AC030GGFX | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 9 lb | 115.0 mm | down to 0.01 MICRON | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 1 to 16 barg | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 35 to 86 °F | 11 psi Initial Dry, 100% Flow | Oil Vapour Reduction | 5.1 inch | 28.9 inch | P030AA and 030AC<br/>Requires Both | 030AA:<br/> 12 Months<br/><br/>030AC:<br/> When oil vapour is detected | BSPP | Automatic Float | Double Stage | 1½ inch | 305 m³/h @ 7 barg (180 cfm @ 102 psig) | |
ACSPX010AGMX | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 1.8 lb | 2.56 inch | n/a | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 1 to 20 barg | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | 0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 2 to 50 °C | < 61 mbar Initial Dry, 100% Flow | Oil Vapour Reduction | 76.0 mm | 180.0 mm | P010ACS | When Oil Vapour is detected | BSPP | Manual | Single Stage | ¼ inch | 36 m³/h @ 7 barg (21 cfm @ 102 psig) | |
ACSPX010ANMX | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 1.8 lb | 65.0 mm | n/a | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 1 to 20 barg | Fully tested - In accordance with ISO8573-5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | 0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 2 to 50 °C | 0.9 psi Initial Dry, 100% Flow | Oil Vapour Reduction | 76.0 mm | 180.0 mm | P010ACS | When Oil Vapour is detected | NPT | Manual | Single Stage | ¼ inch | 36 m³/h @ 7 barg (21 cfm @ 102 psig) | |
ACSPX010BGMX | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 1.8 lb | 65.0 mm | n/a | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 15 to 290 psig | Fully tested - In accordance with ISO8573-5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | 0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 35 to 122 °F | < 53 mbar Initial Dry, 100% Flow | Oil Vapour Reduction | 76.0 mm | 7.09 inch | P010ACS | When Oil Vapour is detected | BSPP | Manual | Single Stage | ⅜ inch | 36 m³/h @ 7 barg (21 cfm @ 102 psig) | |
ACSPX010BNMX | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 0.81 kg | 2.56 inch | n/a | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 1 to 20 barg | Fully tested - In accordance with ISO8573-5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | 0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 2 to 50 °C | < 53 mbar Initial Dry, 100% Flow | Oil Vapour Reduction | 2.99 inch | 180.0 mm | P010ACS | When Oil Vapour is detected | NPT | Manual | Single Stage | ⅜ inch | 36 m³/h @ 7 barg (21 cfm @ 102 psig) | |
ACSPX010CGMX | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 1.8 lb | 65.0 mm | n/a | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 15 to 290 psig | Fully tested - In accordance with ISO8573-5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | 0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 2 to 50 °C | < 55 mbar Initial Dry, 100% Flow | Oil Vapour Reduction | 2.99 inch | 180.0 mm | P010ACS | When Oil Vapour is detected | BSPP | Manual | Single Stage | ½ inch | 36 m³/h @ 7 barg (21 cfm @ 102 psig) | |
ACSPX010CNMX | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 0.81 kg | 65.0 mm | n/a | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 15 to 290 psig | Fully tested - In accordance with ISO8573-5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | 0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 2 to 50 °C | 0.8 | Oil Vapour Reduction | 2.99 inch | 7.09 inch | P010ACS | When Oil Vapour is detected | NPT | Manual | Single Stage | ½ inch | 36 m³/h @ 7 barg (21 cfm @ 102 psig) | |
ACSPX015BGMX | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 3.10 lb | 84.0 mm | n/a | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 1 to 20 barg | Fully tested - In accordance with ISO8573-5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | 0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 2 to 50 °C | < 65 mbar Initial Dry, 100% Flow | Oil Vapour Reduction | 89.0 mm | 9.37 inch | P015ACS | When Oil Vapour is detected | BSPP | Manual | Single Stage | ⅜ inch | 72 m³/h @ 7 barg (42 cfm @ 102 psig) | |
ACSPX015BNMX | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 3.10 lb | 84.0 mm | n/a | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 1 to 20 barg | Fully tested - In accordance with ISO8573-5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | 0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 35 to 122 °F | 0.9 | Oil Vapour Reduction | 89.0 mm | 9.37 inch | P015ACS | When Oil Vapour is detected | NPT | Manual | Single Stage | ⅜ inch | 72 m³/h @ 7 barg (42 cfm @ 102 psig) | |
ACSPX015CGMX | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 1.41 kg | 3.31 inch | n/a | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 1 to 20 barg | Fully tested - In accordance with ISO8573-5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | 0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 2 to 50 °C | < 46 mbar Initial Dry, 100% Flow | Oil Vapour Reduction | 3.5 inch | 9.37 inch | P015ACS | When Oil Vapour is detected | BSPP | Manual | Single Stage | ½ inch | 72 m³/h @ 7 barg (42 cfm @ 102 psig) | |
ACSPX015CNMX | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 3.10 lb | 3.31 inch | n/a | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 1 to 20 barg | Fully tested - In accordance with ISO8573-5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | 0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 2 to 50 °C | < 46 mbar Initial Dry, 100% Flow | Oil Vapour Reduction | 89.0 mm | 9.37 inch | P015ACS | When Oil Vapour is detected | NPT | Manual | Single Stage | ½ inch | 72 m³/h @ 7 barg (42 cfm @ 102 psig) | |
ACSPX020CGMX | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 1.41 kg | 3.31 inch | n/a | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 15 to 290 psig | Fully tested - In accordance with ISO8573-5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | 0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 2 to 50 °C | 1.1 | Oil Vapour Reduction | 89.0 mm | 9.37 inch | P020ACS | When Oil Vapour is detected | BSPP | Manual | Single Stage | ½ inch | 108 m³/h @ 7 barg (64 cfm @ 102 psig) | |
ACSPX020CNMX | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 3.10 lb | 84.0 mm | n/a | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 1 to 20 barg | Fully tested - In accordance with ISO8573-5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | 0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 35 to 122 °F | < 77 | Oil Vapour Reduction | 89.0 mm | 238.0 mm | P020ACS | When Oil Vapour is detected | NPT | Manual | Single Stage | ½ inch | 108 m³/h @ 7 barg (64 cfm @ 102 psig) | |
ACSPX020DGMX | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 1.41 kg | 84.0 mm | n/a | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 15 to 290 psig | Fully tested - In accordance with ISO8573-5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | 0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 2 to 50 °C | 1.1 psi Initial Dry, 100% Flow | Oil Vapour Reduction | 89.0 mm | 9.37 inch | P020ACS | When Oil Vapour is detected | BSPP | Manual | Single Stage | ¾ inch | 108 m³/h @ 7 barg (64 cfm @ 102 psig) | |
ACSPX020DNMX | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 1.41 kg | 3.31 inch | n/a | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 1 to 20 barg | Fully tested - In accordance with ISO8573-5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | 0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 35 to 122 °F | < 79 | Oil Vapour Reduction | 3.5 inch | 238.0 mm | P020ACS | When Oil Vapour is detected | NPT | Manual | Single Stage | ¾ inch | 108 m³/h @ 7 barg (64 cfm @ 102 psig) | |
ACSPX025DGMX | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 2.66 kg | 115.0 mm | n/a | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 1 to 20 barg | Fully tested - In accordance with ISO8573-5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | 0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 2 to 50 °C | 1.0 psi Initial Dry, 100% Flow | Oil Vapour Reduction | 120.0 mm | 10.91 inch | P025ACS | When Oil Vapour is detected | BSPP | Manual | Single Stage | ¾ inch | 216 m³/h @ 7 barg (127 cfm @ 102 psig) | |
ACSPX025DNMX | Backordered | POR | PARKER | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | 2.66 kg | 4.53 inch | n/a | Compressed Air Filter | Die Cast Aluminium | OIL-X Grades ACS and AC | 15 to 290 psig | Fully tested - In accordance with ISO8573-5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | 0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 35 to 122 °F | < 66 | Oil Vapour Reduction | 4.72 inch | 277.0 mm | P025ACS | When Oil Vapour is detected | NPT | Manual | Single Stage | ¾ inch | 216 m³/h @ 7 barg (127 cfm @ 102 psig) |
REWARD Status
Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.
Click quantity In Stock to view warehouse location detail.