• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Application
  • Body Material
  • Brand
  • Connection Type
  • Division
  • Division
  • Electrical Connection
  • Electronics Type
  • Filter Efficiency Rating
More Filters...

Pilot Operated Proportional Directional Control Valve - Series D31FC / D41FC / D91FC / D111FC

Picture for category Pilot Operated Proportional Directional Control Valve - Series D31FC / D41FC / D91FC / D111FC

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The pilot operated proportional directional control valves series D*1FC is characterized by a high-precision position feedback system for improved process accuracy and and simple parametrization .

The D*1FC series is equipped with a modern, high-definition position feedback system. The parameters of the valve electronics can be accessed where required via the free, user-friendly ProPxD software. The integrated diagnostics function also makes optimal configuration easier.

D*1FC with EtherCAT
These valves are actuated and monitored by the EtherCAT® interface. Actual value (spool position), temperature, operating hours and different error messages are available as diagnostic signals. The valve parameters are factory set and can be adapted with the Parker ProPxD software via the parametrizing interface.

In addition to the fieldbus communication, the valves provide the range of functions of the standard version including  E2analogue  command signal and diagnostic spare stroke. Thus they can be operated independent of the fieldbus control, particularly during commissioning and maintenance.

Markets:
• Industrial
• Power generation
• Machine tools
• Rubber & tire processing

Features/Benefits:
• High-quality mechanical design - pilot valve is based on the tried and tested D1FB control valve with spool/sleeve design and guarantees pilot control with high precision
• Progressive flow characteristics - allows sensitive adjustment of flow rate
• Low hysteresis - ensures high repeatability and thus improved process and product accuracy
• High dynamics - suitable for demanding open loop applications
• High flow capacity - optimum efficiency in relation to valve size
• Parametrizable via Parker ProPxD soft - quick and easy adjustment of parameters
• Excellent price-performance ratio - fast return of investment
• Short delivery time - no storage necessary
• Centre position monitoring optional
• A-regeneration optional - for new energy saving circuits with differential cylinders
• Switchable hybrid version optional - can switch between regenerative mode and standard mode at any time
• Version with EtherCAT® interface, 2x M12x1 connector 4-Pin (EtherCAT® In and EtherCAT® Out)

Applications:
• General presses
• Tire presses
• Machine tool
• Injection molding
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceBrandFunctionMaximum Flow RateDivisionMaximum Operating PressureMounting TypeSeal MaterialOperation TypeTechnologyBody MaterialMounting PositionMediaApplicationMinimum Fluid TemperatureMaximum Kinematic ViscosityMinimum Ambient TemperatureActuation TypeFor Fluid TypeMinimum Kinematic ViscosityValve TypeDivisionProduct SeriesMaximum Fluid TemperatureFlow RateElectronics TypeVibration ResistanceMaximum Pilot PressureIngress Protection RatingVariation of Opening PointWeightResponse TimePower Supply VoltageMinimum Pilot PressureSeal MaterialPort ConnectionFlow RateSpool CodeValve OptionConnection TypeSignal InputFlow DirectionPilot Inlet / Drain LocationsMaximum Ambient TemperatureFilter Efficiency RatingLeak RateHysteresisMounting Style
D111FCB32LC2NB00
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minB32Standard6 + PE0-±10 V0-10 V = P-BExternal/external
D111FCB32LC2NB70
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted400 cSt-20 °CProportionalWater-Glycol20 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minB32Standard6 + PE + enable0-±10 V0-10 V = P-BExternal/external60 °CISO 4406 18/16/131000 ml/min≤ 0.1 %NFPA
D111FCB32LC2NE70
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °CSolenoidHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minB32Standard6 + PE + enable0-±20 mA0-20 mA = P-BExternal/external
D111FCB32LC2NK70
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minB32Standard6 + PE + enable0-±10 V0-10 V = P-AExternal/external60 °CISO 4406 18/16/131000 ml/min≤ 0.1 %ISO 4401
D111FCB32LC2NS00
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted400 cSt-20 °CSolenoidWater-Glycol20 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minB32Standard6 + PE4-20 mA12-20 mA = P-AExternal/external60 °CISO 4406 18/16/131000 ml/min≤ 0.1 %CETOP RP121
D111FCB32LC2NS70
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °CProportionalWater-Glycol20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minB32Standard6 + PE + enable4-20 mA12-20 mA = P-AExternal/external
D111FCB32LC2VB70
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateFPMPilotCast IronUnrestricted400 cSt-20 °CSolenoidWater-Glycol20 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barFPMNG32 / CETOP 101000 l/minB32Standard6 + PE + enable0-±10 V0-10 V = P-BExternal/external60 °CISO 4406 18/16/131000 ml/min≤ 0.1 %ISO 4401
D111FCB32LC4NB00
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °CProportionalWater-Glycol20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minB32Standard6 + PE0-±10 V0-10 V = P-BInternal/internal
D111FCB32LC4NB70
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted400 cSt-20 °CSolenoidHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minB32Standard6 + PE + enable0-±10 V0-10 V = P-BInternal/internal60 °CISO 4406 18/16/131000 ml/min≤ 0.1 %NFPA
D111FCE01HC1NB70
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °CSolenoidHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minE01Standard6 + PE + enable0-±10 V0-10 V = P-BInternal/external
D111FCE01HC2NS70
Backordered
POR
Industrial Systems Division EuropeNBRNG32 / CETOP 101000 l/minE01Standard6 + PE + enable4-20 mA12-20 mA = P-AExternal/external
D111FCE01HC4NB70
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 10450 l/minE01Standard6 + PE + enable0-±10 V0-10 V = P-BInternal/internal60 °CISO 4406 18/16/131000 ml/min≤ 0.1 %DIN 24340
D111FCE01LC1NB00
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °CSolenoidHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minE01Standard6 + PE0-±10 V0-10 V = P-BInternal/external
D111FCE01LC1NB70
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted400 cSt-20 °CSolenoidWater-Glycol20 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minE01Standard6 + PE + enable0-±10 V0-10 V = P-BInternal/external60 °CISO 4406 18/16/131000 ml/min≤ 0.1 %CETOP RP121
D111FCE01LC1NE00
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °CSolenoidHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minE01Standard6 + PE0-±20 mA0-20 mA = P-BInternal/external
D111FCE01LC1NS00
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °CSolenoidWater-Glycol20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minE01Standard6 + PE4-20 mA12-20 mA = P-AInternal/external
D111FCE01LC1NS70
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minE01Standard6 + PE + enable4-20 mA12-20 mA = P-AInternal/external60 °CISO 4406 18/16/131000 ml/min≤ 0.1 %CETOP RP121
D111FCE01LC1VB70
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateFPMPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-20 °C400 cSt-20 °CProportionalWater-Glycol20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barFPMNG32 / CETOP 101000 l/minE01Standard6 + PE + enable0-±10 V0-10 V = P-BInternal/external
D111FCE01LC2NB00
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minE01Standard6 + PE0-±10 V0-10 V = P-BExternal/external60 °CISO 4406 18/16/131000 ml/min≤ 0.1 %ISO 4401
D111FCE01LC2NB08
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °CProportionalHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minE01Monitor switch6 + PE0-±10 V0-10 V = P-BExternal/external

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains