The pilot operated proportional directional control valves series D*1FC is characterized by a high-precision position feedback system for improved process accuracy and and simple parametrization .

The D*1FC series is equipped with a modern, high-definition position feedback system. The parameters of the valve electronics can be accessed where required via the free, user-friendly ProPxD software. The integrated diagnostics function also makes optimal configuration easier.

D*1FC with EtherCAT
These valves are actuated and monitored by the EtherCAT® interface. Actual value (spool position), temperature, operating hours and different error messages are available as diagnostic signals. The valve parameters are factory set and can be adapted with the Parker ProPxD software via the parametrizing interface.

In addition to the fieldbus communication, the valves provide the range of functions of the standard version including  E2analogue  command signal and diagnostic spare stroke. Thus they can be operated independent of the fieldbus control, particularly during commissioning and maintenance.

Markets:
• Industrial
• Power generation
• Machine tools
• Rubber & tire processing

Features/Benefits:
• High-quality mechanical design - pilot valve is based on the tried and tested D1FB control valve with spool/sleeve design and guarantees pilot control with high precision
• Progressive flow characteristics - allows sensitive adjustment of flow rate
• Low hysteresis - ensures high repeatability and thus improved process and product accuracy
• High dynamics - suitable for demanding open loop applications
• High flow capacity - optimum efficiency in relation to valve size
• Parametrizable via Parker ProPxD soft - quick and easy adjustment of parameters
• Excellent price-performance ratio - fast return of investment
• Short delivery time - no storage necessary
• Centre position monitoring optional
• A-regeneration optional - for new energy saving circuits with differential cylinders
• Switchable hybrid version optional - can switch between regenerative mode and standard mode at any time
• Version with EtherCAT® interface, 2x M12x1 connector 4-Pin (EtherCAT® In and EtherCAT® Out)

Applications:
• General presses
• Tire presses
• Machine tool
• Injection molding
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceFunctionActuation TypeMaximum Flow RateDivisionMaximum Operating PressureMounting TypeSeal MaterialOperation TypeBody MaterialMounting PositionMaximum Ambient TemperatureMaximum Kinematic ViscosityMinimum Ambient TemperatureFilter Efficiency RatingFor Fluid TypeMinimum Kinematic ViscosityProduct SeriesFlow RateLeak RateElectronics TypeVibration ResistanceMaximum Pilot PressureIngress Protection RatingVariation of Opening PointWeightHysteresisResponse TimeMounting StylePower Supply VoltageMinimum Pilot PressureSeal MaterialPort ConnectionFlow RateValve OptionSpool CodeSignal InputFlow DirectionConnection TypePilot Inlet / Drain LocationsBrandTechnologyMediaApplicationMinimum Fluid TemperatureValve TypeDivisionMaximum Fluid Temperature
D111FCE02HC2VB70
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateFPMPilotCast IronUnrestricted60 °C400 cSt-20 °CISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC Valve1000.0 L/min1000 ml/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg≤ 0.1 %15.0 msISO 440118...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barFPMNG32 / CETOP 101000 l/minStandardE020-±10 V0-10 V = P-B6 + PE + enableExternal/external
D111FCE02HC2VS70
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateFPMPilotCast IronUnrestricted400 cSt-20 °CWater-Glycol20 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barFPMNG32 / CETOP 101000 l/minStandardE024-20 mA12-20 mA = P-A6 + PE + enableExternal/externalPARKERHydraulicsHydraulic OilIndustrial Hydraulic-20 °CProportional DC ValveIndustrial Systems Division Europe60 °C
D111FCE02LC1NB10
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted60 °C400 cSt-20 °CISO 4406 18/16/13Water-Glycol20 cStProportional DC Valve1000.0 L/min1000 ml/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg≤ 0.1 %15.0 msCETOP RP12118...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minStandardE020-±10 V0-10 V = P-B6 + PE + enable with solenoid disableInternal/external
D111FCE02LC1NB70
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted400 cSt-20 °CHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minStandardE020-±10 V0-10 V = P-B6 + PE + enableInternal/externalPARKERHydraulicsHydraulic OilIndustrial Hydraulic-25 °CProportional DC ValveIndustrial Systems Division Europe60 °C
D111FCE02LC1NE00
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted60 °C400 cSt-20 °CISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC Valve1000.0 L/min1000 ml/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg≤ 0.1 %15.0 msISO 440118...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minStandardE020-±20 mA0-20 mA = P-B6 + PEInternal/external
D111FCE02LC1NS00
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted60 °C400 cSt-20 °CISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC Valve1000.0 L/min1000 ml/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg≤ 0.1 %15.0 msISO 440118...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minStandardE024-20 mA12-20 mA = P-A6 + PEInternal/external
D111FCE02LC1NS70
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted400 cSt-20 °CWater-Glycol20 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minStandardE024-20 mA12-20 mA = P-A6 + PE + enableInternal/externalPARKERHydraulicsHydraulic OilIndustrial Hydraulic-25 °CProportional DC ValveIndustrial Systems Division Europe60 °C
D111FCE02LC2NB00
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted60 °C400 cSt-20 °CISO 4406 18/16/13Water-Glycol20 cStProportional DC Valve1000.0 L/min1000 ml/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg≤ 0.1 %15.0 msNFPA18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minStandardE020-±10 V0-10 V = P-B6 + PEExternal/external
D111FCE02LC2NB08
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted400 cSt-20 °CHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minMonitor switchE020-±10 V0-10 V = P-B6 + PEExternal/externalPARKERHydraulicsHydraulic OilIndustrial Hydraulic-25 °CProportional DC ValveIndustrial Systems Division Europe60 °C
D111FCE02LC2NB70
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted60 °C400 cSt-20 °CISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC Valve1000.0 L/min1000 ml/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg≤ 0.1 %15.0 msCETOP RP12118...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minStandardE020-±10 V0-10 V = P-B6 + PE + enableExternal/external
D111FCE02LC2NK70
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted400 cSt-20 °CWater-Glycol20 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minStandardE020-±10 V0-10 V = P-A6 + PE + enableExternal/externalPARKERHydraulicsHydraulic OilIndustrial Hydraulic-25 °CProportional DC ValveIndustrial Systems Division Europe60 °C
D111FCE02LC2NS00
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted400 cSt-20 °CWater-Glycol20 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minStandardE024-20 mA12-20 mA = P-A6 + PEExternal/externalPARKERHydraulicsHydraulic OilIndustrial Hydraulic-25 °CProportional DC ValveIndustrial Systems Division Europe60 °C
D111FCE02LC2NS70
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted60 °C400 cSt-20 °CISO 4406 18/16/13Water-Glycol20 cStProportional DC Valve1000.0 L/min1000 ml/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg≤ 0.1 %15.0 msDIN 2434018...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minStandardE024-20 mA12-20 mA = P-A6 + PE + enableExternal/external
D111FCE02LC2VB70
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateFPMPilotCast IronUnrestricted400 cSt-20 °CHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barFPMNG32 / CETOP 101000 l/minStandardE020-±10 V0-10 V = P-B6 + PE + enableExternal/externalPARKERHydraulicsHydraulic OilIndustrial Hydraulic-20 °CProportional DC ValveIndustrial Systems Division Europe60 °C
D111FCE02LC2VS00
Backordered
POR
Industrial Systems Division EuropeFPMNG32 / CETOP 101000 l/minStandardE024-20 mA12-20 mA = P-A6 + PEExternal/external
D111FCE02LC4NB00
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted60 °C400 cSt-20 °CISO 4406 18/16/13Water-Glycol20 cStProportional DC Valve1000.0 L/min1000 ml/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg≤ 0.1 %15.0 msISO 440118...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minStandardE020-±10 V0-10 V = P-B6 + PEInternal/internal
D111FCE02LC4NB70
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted400 cSt-20 °CHydraulic Oil According to DIN 51524 ... 53520 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minStandardE020-±10 V0-10 V = P-B6 + PE + enableInternal/internalPARKERHydraulicsHydraulic OilIndustrial Hydraulic-25 °CProportional DC ValveIndustrial Systems Division Europe60 °C
D111FCE02LC4NE00
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted60 °C400 cSt-20 °CISO 4406 18/16/13Water-Glycol20 cStProportional DC Valve1000.0 L/min1000 ml/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg≤ 0.1 %15.0 msNFPA18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minStandardE020-±20 mA0-20 mA = P-B6 + PEInternal/internal
D111FCE02LC4NS70
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted400 cSt-20 °CWater-Glycol20 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minStandardE024-20 mA12-20 mA = P-A6 + PE + enableInternal/internalPARKERHydraulicsHydraulic OilIndustrial Hydraulic-25 °CProportional DC ValveIndustrial Systems Division Europe60 °C
D111FCR31LC4NS70
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRPilotCast IronUnrestricted60 °C400 cSt-20 °CISO 4406 18/16/13Water-Glycol20 cStProportional DC Valve1000.0 L/min1000 ml/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg≤ 0.1 %15.0 msDIN 2434018...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minStandardR314-20 mA12-20 mA = P-A6 + PE + enableInternal/internal

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains