Pilot Operated Proportional Directional Control Valve - Series D31FC / D41FC / D91FC / D111FC

Picture for category Pilot Operated Proportional Directional Control Valve - Series D31FC / D41FC / D91FC / D111FC

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The pilot operated proportional directional control valves series D*1FC is characterized by a high-precision position feedback system for improved process accuracy and and simple parametrization .

The D*1FC series is equipped with a modern, high-definition position feedback system. The parameters of the valve electronics can be accessed where required via the free, user-friendly ProPxD software. The integrated diagnostics function also makes optimal configuration easier.

D*1FC with EtherCAT
These valves are actuated and monitored by the EtherCAT® interface. Actual value (spool position), temperature, operating hours and different error messages are available as diagnostic signals. The valve parameters are factory set and can be adapted with the Parker ProPxD software via the parametrizing interface.

In addition to the fieldbus communication, the valves provide the range of functions of the standard version including  E2analogue  command signal and diagnostic spare stroke. Thus they can be operated independent of the fieldbus control, particularly during commissioning and maintenance.

Markets:
• Industrial
• Power generation
• Machine tools
• Rubber & tire processing

Features/Benefits:
• High-quality mechanical design - pilot valve is based on the tried and tested D1FB control valve with spool/sleeve design and guarantees pilot control with high precision
• Progressive flow characteristics - allows sensitive adjustment of flow rate
• Low hysteresis - ensures high repeatability and thus improved process and product accuracy
• High dynamics - suitable for demanding open loop applications
• High flow capacity - optimum efficiency in relation to valve size
• Parametrizable via Parker ProPxD soft - quick and easy adjustment of parameters
• Excellent price-performance ratio - fast return of investment
• Short delivery time - no storage necessary
• Centre position monitoring optional
• A-regeneration optional - for new energy saving circuits with differential cylinders
• Switchable hybrid version optional - can switch between regenerative mode and standard mode at any time
• Version with EtherCAT® interface, 2x M12x1 connector 4-Pin (EtherCAT® In and EtherCAT® Out)

Applications:
• General presses
• Tire presses
• Machine tool
• Injection molding
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceBrandFunctionActuation TypeMaximum Flow RateDivisionMaximum Operating PressureMounting TypeSeal MaterialFor Fluid TypeOperation TypeTechnologyBody MaterialMounting PositionMediaApplicationMinimum Fluid TemperatureMaximum Kinematic ViscosityMinimum Ambient TemperatureMinimum Kinematic ViscosityValve TypeDivisionProduct SeriesMaximum Fluid TemperatureFlow RateElectronics TypeVibration ResistanceMaximum Pilot PressureIngress Protection RatingVariation of Opening PointWeightResponse TimePower Supply VoltageMinimum Pilot PressureSeal MaterialPort ConnectionFlow RateValve OptionConnection TypeSignal InputFlow DirectionPilot Inlet / Drain LocationsSpool CodeMaximum Ambient TemperatureFilter Efficiency RatingLeak RateHysteresisMounting StyleMaximum Operating TemperatureMinimum Operating Temperature
D111FCR32LC2NK00
Backordered
POR
PARKER3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °C20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minStandard6 + PE0-±10 V0-10 V = P-AExternal/externalR32
D111FCR32LC2NS00
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotCast IronUnrestricted400 cSt-20 °C20 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minStandard6 + PE4-20 mA12-20 mA = P-AExternal/externalR3260 °CISO 4406 18/16/131000 ml/min≤ 0.1 %CETOP RP121
D111FCZ32LC1NB7L
Backordered
POR
PARKER3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °C20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minHybrid valve6 + PE + enable0-±10 V0-10 V = P-BInternal/externalZ32
D111FCZ32LC2NS0L
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotCast IronUnrestricted400 cSt-20 °C20 cStProportional DC Valve1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG32 / CETOP 101000 l/minHybrid valve6 + PE4-20 mA12-20 mA = P-AExternal/externalZ3260 °CISO 4406 18/16/131000 ml/min≤ 0.1 %ISO 4401
D111FCZ32LC4VB0L
Backordered
POR
PARKER3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateFPMWater-GlycolPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-20 °C400 cSt-20 °C20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C1000.0 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal68.5 kg15.0 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barFPMNG32 / CETOP 101000 l/minHybrid valve6 + PE0-±10 V0-10 V = P-BInternal/internalZ32
D31FCB31DC1NB70
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotCast IronUnrestricted400 cSt-20 °C20 cStProportional DC Valve90 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal9 kg2.9 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG10 / CETOP 0590 l/minStandard6 + PE + enable0-±10 V0-10 V = P-BInternal/externalB3160 °CISO 4406 18/16/13200 ml/min≤ 0.1 %DIN 24340
D31FCB31DC1NB78
Backordered
POR
PARKER3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °C20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C90 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal9 kg2.9 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG10 / CETOP 0590 l/minMonitor switch6 + PE + enable0-±10 V0-10 V = P-BInternal/externalB3160 °C-20 °C
D31FCB31DC1NE70
Backordered
POR
PARKER3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °C20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C90 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal9 kg2.9 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG10 / CETOP 0590 l/minStandard6 + PE + enable0-±20 mA0-20 mA = P-BInternal/externalB31
D31FCB31DC1NS00
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotCast IronUnrestricted400 cSt-20 °C20 cStProportional DC Valve90 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal9 kg2.9 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG10 / CETOP 0590 l/minStandard6 + PE4-20 mA12-20 mA = P-AInternal/externalB3160 °CISO 4406 18/16/13200 ml/min≤ 0.1 %CETOP RP121
D31FCB31DC2NB08
Backordered
POR
PARKER3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °C20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C90 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal9 kg2.9 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG10 / CETOP 0590 l/minMonitor switch6 + PE0-±10 V0-10 V = P-BExternal/externalB31
D31FCB31DC2NB70
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotCast IronUnrestricted400 cSt-20 °C20 cStProportional DC Valve90 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal9 kg2.9 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG10 / CETOP 0590 l/minStandard6 + PE + enable0-±10 V0-10 V = P-BExternal/externalB3160 °CISO 4406 18/16/13200 ml/min≤ 0.1 %DIN 24340
D31FCB31DC2NK00
Backordered
POR
PARKER3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °C20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C90 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal9 kg2.9 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG10 / CETOP 0590 l/minStandard6 + PE0-±10 V0-10 V = P-AExternal/externalB31
D31FCB31DC2NS70
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotCast IronUnrestricted400 cSt-20 °C20 cStProportional DC Valve90 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal9 kg2.9 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG10 / CETOP 0590 l/minStandard6 + PE + enable4-20 mA12-20 mA = P-AExternal/externalB3160 °CISO 4406 18/16/13200 ml/min≤ 0.1 %NFPA
D31FCB31DC4NB00
Backordered
POR
PARKER3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °C20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C90 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal9 kg2.9 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG10 / CETOP 0590 l/minStandard6 + PE0-±10 V0-10 V = P-BInternal/internalB31
D31FCB31DC4NB70
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotCast IronUnrestricted400 cSt-20 °C20 cStProportional DC Valve90 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal9 kg2.9 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG10 / CETOP 0590 l/minStandard6 + PE + enable0-±10 V0-10 V = P-BInternal/internalB3160 °CISO 4406 18/16/13200 ml/min≤ 0.1 %ISO 4401
D31FCB31DC4NS70
Backordered
POR
PARKER3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °C20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C90 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal9 kg2.9 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG10 / CETOP 0590 l/minStandard6 + PE + enable4-20 mA12-20 mA = P-AInternal/internalB31
D31FCB31DC4VB70
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateFPMWater-GlycolPilotCast IronUnrestricted400 cSt-20 °C20 cStProportional DC Valve90 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal9 kg2.9 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barFPMNG10 / CETOP 0590 l/minStandard6 + PE + enable0-±10 V0-10 V = P-BInternal/internalB3160 °CISO 4406 18/16/13200 ml/min≤ 0.1 %CETOP RP121
D31FCB31DC5NB00
Backordered
POR
PARKER3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °C20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C90 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal9 kg2.9 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG10 / CETOP 0590 l/minStandard6 + PE0-±10 V0-10 V = P-BExternal/internalB31
D31FCB31DC5NB70
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotCast IronUnrestricted400 cSt-20 °C20 cStProportional DC Valve90 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal9 kg2.9 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG10 / CETOP 0590 l/minStandard6 + PE + enable0-±10 V0-10 V = P-BExternal/internalB3160 °CISO 4406 18/16/13200 ml/min≤ 0.1 %ISO 4401
D31FCB31EC1NE08
Backordered
POR
PARKER3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °C20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C120 L/minOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal9 kg2.9 ms18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 barNBRNG10 / CETOP 05120 L/MINMonitor switch6 + PE0-±20 mA0-20 mA = P-BInternal/externalB31

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains