• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Application
  • Body Material
  • Brand
  • Connection Type
  • Division
  • Division
  • Electrical Connection
  • Electronics Type
  • Filter Efficiency Rating
More Filters...

Pilot Operated Proportional Directional Control Valve - Series D31FC / D41FC / D91FC / D111FC

Picture for category Pilot Operated Proportional Directional Control Valve - Series D31FC / D41FC / D91FC / D111FC

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The pilot operated proportional directional control valves series D*1FC is characterized by a high-precision position feedback system for improved process accuracy and and simple parametrization .

The D*1FC series is equipped with a modern, high-definition position feedback system. The parameters of the valve electronics can be accessed where required via the free, user-friendly ProPxD software. The integrated diagnostics function also makes optimal configuration easier.

D*1FC with EtherCAT
These valves are actuated and monitored by the EtherCAT® interface. Actual value (spool position), temperature, operating hours and different error messages are available as diagnostic signals. The valve parameters are factory set and can be adapted with the Parker ProPxD software via the parametrizing interface.

In addition to the fieldbus communication, the valves provide the range of functions of the standard version including  E2analogue  command signal and diagnostic spare stroke. Thus they can be operated independent of the fieldbus control, particularly during commissioning and maintenance.

Markets:
• Industrial
• Power generation
• Machine tools
• Rubber & tire processing

Features/Benefits:
• High-quality mechanical design - pilot valve is based on the tried and tested D1FB control valve with spool/sleeve design and guarantees pilot control with high precision
• Progressive flow characteristics - allows sensitive adjustment of flow rate
• Low hysteresis - ensures high repeatability and thus improved process and product accuracy
• High dynamics - suitable for demanding open loop applications
• High flow capacity - optimum efficiency in relation to valve size
• Parametrizable via Parker ProPxD soft - quick and easy adjustment of parameters
• Excellent price-performance ratio - fast return of investment
• Short delivery time - no storage necessary
• Centre position monitoring optional
• A-regeneration optional - for new energy saving circuits with differential cylinders
• Switchable hybrid version optional - can switch between regenerative mode and standard mode at any time
• Version with EtherCAT® interface, 2x M12x1 connector 4-Pin (EtherCAT® In and EtherCAT® Out)

Applications:
• General presses
• Tire presses
• Machine tool
• Injection molding
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceFunctionActuation TypeMaximum Flow RateDivisionMaximum Operating PressureMounting TypeSeal MaterialFor Fluid TypeOperation TypeBody MaterialMounting PositionMaximum Ambient TemperatureMaximum Kinematic ViscosityMinimum Ambient TemperatureWeightFlow RateFilter Efficiency RatingMinimum Kinematic ViscosityProduct SeriesElectronics TypeVibration ResistanceMaximum Pilot PressureIngress Protection RatingVariation of Opening PointHysteresisMounting StylePower Supply VoltageMinimum Pilot PressureLeak RateResponse TimeSeal MaterialPort ConnectionFlow RateSpool CodeValve OptionSignal InputFlow DirectionConnection TypePilot Inlet / Drain LocationsBrandTechnologyMediaApplicationMinimum Fluid TemperatureValve TypeDivisionMaximum Fluid Temperature
D31FCB31EC1VK70
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateFPMWater-GlycolPilotCast IronUnrestricted60 °C400 cSt-20 °C9 kg120 L/minISO 4406 18/16/1320 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal≤ 0.1 %NFPA18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar200 ml/min2.9 msFPMNG10 / CETOP 05120 L/MINB31Standard0-±10 V0-10 V = P-A6 + PE + enableInternal/external
D31FCB31EC2NB00
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotCast IronUnrestricted400 cSt-20 °C9 kg120 L/min20 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar2.9 msNBRNG10 / CETOP 05120 L/MINB31Standard0-±10 V0-10 V = P-B6 + PEExternal/externalPARKERHydraulicsHydraulic OilIndustrial Hydraulic-25 °CProportional DC ValveIndustrial Systems Division Europe60 °C
D31FCB31EC2NK00
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotCast IronUnrestricted60 °C400 cSt-20 °C9 kg120 L/minISO 4406 18/16/1320 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal≤ 0.1 %ISO 440118...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar200 ml/min2.9 msNBRNG10 / CETOP 05120 L/MINB31Standard0-±10 V0-10 V = P-A6 + PEExternal/external
D31FCB31EC2NK70
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotCast IronUnrestricted400 cSt-20 °C9 kg120 L/min20 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar2.9 msNBRNG10 / CETOP 05120 L/MINB31Standard0-±10 V0-10 V = P-A6 + PE + enableExternal/externalPARKERHydraulicsHydraulic OilIndustrial Hydraulic-25 °CProportional DC ValveIndustrial Systems Division Europe60 °C
D31FCB31EC4NB00
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotCast IronUnrestricted400 cSt-20 °C9 kg120 L/min20 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar2.9 msNBRNG10 / CETOP 05120 L/MINB31Standard0-±10 V0-10 V = P-B6 + PEInternal/internalPARKERHydraulicsHydraulic OilIndustrial Hydraulic-25 °CProportional DC ValveIndustrial Systems Division Europe60 °C
D31FCB31EC4NB70
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotCast IronUnrestricted60 °C400 cSt-20 °C9 kg120 L/minISO 4406 18/16/1320 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal≤ 0.1 %NFPA18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar200 ml/min2.9 msNBRNG10 / CETOP 05120 L/MINB31Standard0-±10 V0-10 V = P-B6 + PE + enableInternal/internal
D31FCB31EC4NK70
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotCast IronUnrestricted400 cSt-20 °C9 kg120 L/min20 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar2.9 msNBRNG10 / CETOP 05120 L/MINB31Standard0-±10 V0-10 V = P-A6 + PE + enableInternal/internalPARKERHydraulicsHydraulic OilIndustrial Hydraulic-25 °CProportional DC ValveIndustrial Systems Division Europe60 °C
D31FCB31EC4VS00
Backordered
POR
Industrial Systems Division EuropeFPMNG10 / CETOP 05120 L/MINB31Standard4-20 mA12-20 mA = P-A6 + PEInternal/internal
D31FCB32DC1NB70
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotCast IronUnrestricted60 °C400 cSt-20 °C9 kg90 L/minISO 4406 18/16/1320 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal≤ 0.1 %CETOP RP12118...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar200 ml/min2.9 msNBRNG10 / CETOP 0590 l/minB32Standard0-±10 V0-10 V = P-B6 + PE + enableInternal/external
D31FCB32DC1NS70
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotCast IronUnrestricted60 °C400 cSt-20 °C9 kg90 L/minISO 4406 18/16/1320 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal≤ 0.1 %CETOP RP12118...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar200 ml/min2.9 msNBRNG10 / CETOP 0590 l/minB32Standard4-20 mA12-20 mA = P-A6 + PE + enableInternal/external
D31FCB32DC2NB70
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotCast IronUnrestricted400 cSt-20 °C9 kg90 L/min20 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar2.9 msNBRNG10 / CETOP 0590 l/minB32Standard0-±10 V0-10 V = P-B6 + PE + enableExternal/externalPARKERHydraulicsHydraulic OilIndustrial Hydraulic-25 °CProportional DC ValveIndustrial Systems Division Europe60 °C
D31FCB32DC2NE70
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotCast IronUnrestricted60 °C400 cSt-20 °C9 kg90 L/minISO 4406 18/16/1320 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal≤ 0.1 %ISO 440118...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar200 ml/min2.9 msNBRNG10 / CETOP 0590 l/minB32Standard0-±20 mA0-20 mA = P-B6 + PE + enableExternal/external
D31FCB32DC2NS00
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotCast IronUnrestricted400 cSt-20 °C9 kg90 L/min20 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar2.9 msNBRNG10 / CETOP 0590 l/minB32Standard4-20 mA12-20 mA = P-A6 + PEExternal/externalPARKERHydraulicsHydraulic OilIndustrial Hydraulic-25 °CProportional DC ValveIndustrial Systems Division Europe60 °C
D31FCB32DC4NB00
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotCast IronUnrestricted60 °C400 cSt-20 °C9 kg90 L/minISO 4406 18/16/1320 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal≤ 0.1 %CETOP RP12118...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar200 ml/min2.9 msNBRNG10 / CETOP 0590 l/minB32Standard0-±10 V0-10 V = P-B6 + PEInternal/internal
D31FCB32DC4NB08
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotCast IronUnrestricted400 cSt-20 °C9 kg90 L/min20 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar2.9 msNBRNG10 / CETOP 0590 l/minB32Monitor switch0-±10 V0-10 V = P-B6 + PEInternal/internalPARKERHydraulicsHydraulic OilIndustrial Hydraulic-25 °CProportional DC ValveIndustrial Systems Division Europe60 °C
D31FCB32DC4NB70
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotCast IronUnrestricted60 °C400 cSt-20 °C9 kg90 L/minISO 4406 18/16/1320 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal≤ 0.1 %DIN 2434018...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar200 ml/min2.9 msNBRNG10 / CETOP 0590 l/minB32Standard0-±10 V0-10 V = P-B6 + PE + enableInternal/internal
D31FCB32DC4NE00
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotCast IronUnrestricted400 cSt-20 °C9 kg90 L/min20 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar2.9 msNBRNG10 / CETOP 0590 l/minB32Standard0-±20 mA0-20 mA = P-B6 + PEInternal/internalPARKERHydraulicsHydraulic OilIndustrial Hydraulic-25 °CProportional DC ValveIndustrial Systems Division Europe60 °C
D31FCB32DC4NE70
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotCast IronUnrestricted60 °C400 cSt-20 °C9 kg90 L/minISO 4406 18/16/1320 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal≤ 0.1 %NFPA18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar200 ml/min2.9 msNBRNG10 / CETOP 0590 l/minB32Standard0-±20 mA0-20 mA = P-B6 + PE + enableInternal/internal
D31FCB32DC4NS70
Backordered
POR
3-WayProportionaln/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotCast IronUnrestricted400 cSt-20 °C9 kg90 L/min20 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar2.9 msNBRNG10 / CETOP 0590 l/minB32Standard4-20 mA12-20 mA = P-A6 + PE + enableInternal/internalPARKERHydraulicsHydraulic OilIndustrial Hydraulic-25 °CProportional DC ValveIndustrial Systems Division Europe60 °C
D31FCB32DC4VB00
Backordered
POR
3-WaySolenoidn/aIndustrial Systems Division Europe350 barSubplateFPMHydraulic Oil According to DIN 51524 ... 535PilotCast IronUnrestricted60 °C400 cSt-20 °C9 kg90 L/minISO 4406 18/16/1320 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal≤ 0.1 %CETOP RP12118...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar200 ml/min2.9 msFPMNG10 / CETOP 0590 l/minB32Standard0-±10 V0-10 V = P-B6 + PEInternal/internal

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains