• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Actuation Type
  • Adjustment Mechanism
  • Body Material
  • Cavity Size
  • Coil Nut Tightening Torque
  • Coil Type
  • Configuration
  • Configuration
  • Division
More Filters...

2 Way Poppet Type Solenoid Valve

Picture for category 2 Way Poppet Type Solenoid Valve

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s 2-way poppet style solenoid valves feature a proven design that ensures very low leakage when flow is blocked in one direction and minimized pressure drop in the free flow position. These valves can operate with hydraulic system flows as high as 260 lpm and pressures up to 350 bar with normally-open or normally closed configurations available. Parker’s 2-way poppet solenoid valves are ideal for unloading and load holding applications that require low poppet style leakage within mobile, industrial, or manufacturing markets._x000D_
_x000D_
Markets:_x000D_
• Aerial_x000D_
• Construction_x000D_
• Material Handling_x000D_
• Miscellaneous Industrial_x000D_
• Miscellaneous Manufacturing_x000D_
• Miscellaneous Mobile_x000D_
_x000D_
Features & Benefits:_x000D_
• Replaceable one-piece coils with low amp draw_x000D_
• Fast response available_x000D_
• Manual override options_x000D_
• Low leakage spherical poppet_x000D_
• All external parts zinc plated_x000D_
_x000D_
Applications:_x000D_
• Unloading circuits_x000D_
• Load holding applications_x000D_
• Lift circuits_x000D_
_x000D_
Additional Technical Insight:_x000D_
Parker’s 2 way poppet valves are pilot operated, low leakage solenoid actuated valves. Similar to a check valve, these valves will block flow in one direction will very low leakage (5 drops per minute, or less). When actuated, these valves allow flow to pass through the valve. These valves are typically selected due to their low leakage characteristics and their ability to meet higher flow requirements. Poppet valves are often used on single operation actuators or in unloading functions. They are available in normally closed and normally open types with fast response versions available._x000D_
_x000D_
Parker’s two way, two position poppet valves consist of a main poppet, a pilot piston, a spring, and a solenoid coil. _x000D_
_x000D_
The normally closed poppet version of these valves will act as a check valve when the valve is de-energized. This blocks flow in both directions while allowing free flow in the reverse direction. When the coil is energized, the poppet is piloted open (lifts) and allows free flow in the previously checked direction, typically from the side of the cartridge out the nose._x000D_
_x000D_
The normally open poppet version of these valves, when the coil is de-energized, will allow free flow from the side port of the valve (port 2) out the nose of the valve (port 1). Energizing the coil shifts the poppet to block flow in both directions._x000D_
_x000D_
Operation: The normally closed poppet valve is held on its seat by a spring, blocking the pilot flow. This will allow pressure at the inlet port (port 2) to hold the poppet on its seat preventing flow through the valve (port 2 to port 1)._x000D_
_x000D_
If the nose of the cartridge (port 1) is pressurized enough to overcome the spring force, and pushing the poppet off of its seat, flow will be allowed through port 1 to port 2. When the coil is energized, the pilot poppet is lifted off of its seat, venting the pressure inside the poppet to port 1. This creates a pressure imbalance across the main poppet, therefore lifting the poppet and allowing flow from the side to the nose (2 to 1). Because these valves are pilot operated, a minimal amount of pressure differential is necessary (25-50 psi), along with flow between ports 2 and 1 must be present to overcome the spring and lift the poppet._x000D_
_x000D_
The normally open valve pilot is held off its seat by spring force. Pilot flow is vented to port 1, creating a pressure imbalance that moves the main poppet. This differential lifts the poppet allowing flow from the side to nose (2 to 1). Since poppet valves are pilot operated, a minimum amount of pressure differential (25-50 psi) between ports 2 overcomes the spring force to drive the valve pilot and main poppet into their seats, thus blocking flow from port 2 to 1. If the nose of the cartridge (port 1) is pressurized, the pressure will overcome the spring force and solenoid force, pushing the poppet off of its seat, allowing restricted flow through the cartridge (1 to 2).
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceBody MaterialFunctionFlow RateMaximum Operating PressureDivisionMinimum Operating TemperatureFlow DirectionMaximum Flow RateMaximum Kinematic ViscosityMaximum Operating TemperatureOverride FunctionalityCavity SizeMaximum Inlet Pressure RatingSeal MaterialActuation TypeOperation TypeFor Fluid TypeConfigurationValve MaterialFilter Efficiency RatingMounting TypeOperating TemperatureLeak RateInput VoltageWire Mesh Screen IncludedCoil Nut Tightening TorqueAdjustment MechanismFree Reverse FlowWeightCoil TypeResponse TimeInstallation TorqueConfigurationMaximum Inlet Pressure RatingSeal MaterialActuation TypeWire Mesh Screen IncludedFlow Rate
DSH101NS
Backordered
$129.00
N/A2-Way60 L/min5000 psiHydraulic Systems Division-35 °FSide to Nose (2-1)15 Gal/min45-2000 SSU (6 to 420 cSt)+200 °Fn/aC10-2350 barD-Ring (Standard)ElectricalSolenoid OperatedMineral-based or synthetic hydraulic fluidsNormally OpenAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-35 to +200 °F5 drops/min85% of rated voltage at 72°F (20°C) minYes5-7 lb-ftN/ANo0.41 lb5/8" Super Coil70 ms69-75 NmNormally Open5000 PSI, 350 BARD-Ring (Standard)ElectricalYes15 GAL/MIN, 60 L/MIN
DSH101NT
Backordered
$171.60
N/A2-Way60 L/min5000 psiHydraulic Systems Division-37 °CSide to Nose (2-1)60 L/min45-2000 SSU (6 to 420 cSt)+200 °FPush and TwistC10-25000 psiD-Ring (Standard)Electrical, ManualSolenoid operated, Manually operatedMineral-based or synthetic hydraulic fluidsNormally OpenAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-35 to +200 °F5 drops/min85% of rated voltage at 72°F (20°C) minNo5-7 lb-ftN/ANo0.41 lb5/8" Super Coil70 ms51-55 lb-ftNormally Open5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNo15 GAL/MIN, 60 L/MIN
DSH101NTV
Backordered
$177.30
N/A2-Way60 L/min5000 psiHydraulic Systems Division-15 °FSide to Nose (2-1)60 L/min45-2000 SSU (6 to 420 cSt)+204 °CPush and TwistC10-2350 barFluorocarbonElectrical, ManualSolenoid operated, Manually operatedMineral-based or synthetic hydraulic fluidsNormally OpenAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +400 °F5 drops/min85% of rated voltage at 72°F (20°C) minNo5-7 lb-ftN/ANo0.41 lb5/8" Super Coil70 ms69-75 NmNormally Open5000 PSI, 350 BARFluorocarbonElectrical, ManualNo15 GAL/MIN, 60 L/MIN
DSH101NV
Backordered
$126.60
N/A2-Way60 L/min5000 psiHydraulic Systems Division-15 °FSide to Nose (2-1)15 Gal/min45-2000 SSU (6 to 420 cSt)+400 °Fn/aC10-25000 psiFluorocarbonElectricalSolenoid OperatedMineral-based or synthetic hydraulic fluidsNormally OpenAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-26 to +204 °C5 drops/min85% of rated voltage at 72°F (20°C) minNo5-7 lb-ftN/ANo0.41 lb5/8" Super Coil70 ms51-55 lb-ftNormally Open5000 PSI, 350 BARFluorocarbonElectricalNo15 GAL/MIN, 60 L/MIN
DSH121C
74 in stock
$181.50
N/A2-Way24 Gal/min350 barHydraulic Systems Division-34 °CSide to Nose (2-1)24 Gal/min45-2000 SSU (6 to 420 cSt)+121 °Cn/aC12-2350 barNitileElectricalSolenoid OperatedMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250 °F5 drops/min85% of rated voltage at 72°F (20°C) minNo7-10 NmN/ANo0.29 kg5/8" Super Coil100 ms125-131 NmNormally Closed5000 PSI, 350 BARNitrileElectricalNo24 GAL/MIN, 90 L/MIN
DSH121CH
Backordered
POR
N/A2-Way24 Gal/min350 barHydraulic Systems Division-30 °FSide to Nose (2-1)90 L/min45-2000 SSU (6 to 420 cSt)+121 °Cn/aC12-25000 psiNitileElectricalSolenoid OperatedMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250 °F5 drops/min85% of rated voltage at 72°F (20°C) minNo7-10 NmN/ANo0.29 kg5/8" Super Coil60 ms125-131 NmNormally Closed5000 PSI, 350 BARNitrileElectricalNo24 GAL/MIN, 90 L/MIN
DSH121CHR
Backordered
POR
N/A2-Way90 L/min350 barHydraulic Systems Division-34 °CSide to Nose (2-1)90 L/min45-2000 SSU (6 to 420 cSt)+250 °Fn/aC12-2350 barNitileElectricalSolenoid OperatedMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250 °F5 drops/min85% of rated voltage at 72°F (20°C) minNo5-7 lb-ftN/AYes0.29 kg5/8" Super Coil60 ms125-131 NmNormally Closed5000 PSI, 350 BARNitrileElectricalNo24 GAL/MIN, 90 L/MIN
DSH121CHRT
Backordered
POR
N/A2-Way90 L/min350 barHydraulic Systems Division-30 °FSide to Nose (2-1)90 L/min45-2000 SSU (6 to 420 cSt)+250 °FPush and TwistC12-25000 psiNitileElectrical, ManualSolenoid operated, Manually operatedMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250 °F5 drops/min85% of rated voltage at 72°F (20°C) minNo7-10 NmN/AYes0.65 lb5/8" Super Coil60 ms92-96 lb-ftNormally Closed5000 PSI, 350 BARNitrileElectrical, ManualNo24 GAL/MIN, 90 L/MIN
DSH121CHRTV
Backordered
POR
N/A2-Way24 Gal/min5000 psiHydraulic Systems Division-15 °FSide to Nose (2-1)90 L/min45-2000 SSU (6 to 420 cSt)+400 °FPush and TwistC12-25000 psiFluorocarbonElectrical, ManualSolenoid operated, Manually operatedMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-26 to +204 °C5 drops/min85% of rated voltage at 72°F (20°C) minNo5-7 lb-ftN/AYes0.29 kg5/8" Super Coil60 ms92-96 lb-ftNormally Closed5000 PSI, 350 BARFluorocarbonElectrical, ManualNo24 GAL/MIN, 90 L/MIN
DSH121CHT
Backordered
POR
N/A2-Way24 Gal/min5000 psiHydraulic Systems Division-30 °FSide to Nose (2-1)90 L/min45-2000 SSU (6 to 420 cSt)+121 °CPush and TwistC12-2350 barNitileElectrical, ManualSolenoid operated, Manually operatedMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250 °F5 drops/min85% of rated voltage at 72°F (20°C) minNo5-7 lb-ftN/ANo0.29 kg5/8" Super Coil60 ms92-96 lb-ftNormally Closed5000 PSI, 350 BARNitrileElectrical, ManualNo24 GAL/MIN, 90 L/MIN
DSH121CHV
Backordered
POR
N/A2-Way90 L/min350 barHydraulic Systems Division-26 °CSide to Nose (2-1)90 L/min45-2000 SSU (6 to 420 cSt)+204 °Cn/aC12-2350 barFluorocarbonElectricalSolenoid OperatedMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-26 to +204 °C5 drops/min85% of rated voltage at 72°F (20°C) minNo7-10 NmN/ANo0.65 lb5/8" Super Coil60 ms92-96 lb-ftNormally Closed5000 PSI, 350 BARFluorocarbonElectricalNo24 GAL/MIN, 90 L/MIN
DSH121CR
2 in stock
$184.50
N/A2-Way90 L/min350 barHydraulic Systems Division-34 °CSide to Nose (2-1)24 Gal/min45-2000 SSU (6 to 420 cSt)+250 °Fn/aC12-25000 psiNitileElectricalSolenoid OperatedMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250 °F5 drops/min85% of rated voltage at 72°F (20°C) minNo7-10 NmN/AYes0.65 lb5/8" Super Coil100 ms92-96 lb-ftNormally Closed5000 PSI, 350 BARNitrileElectricalNo24 GAL/MIN, 90 L/MIN
DSH121CRT
6 in stock
$234.90
N/A2-Way90 L/min350 barHydraulic Systems Division-34 °CSide to Nose (2-1)24 Gal/min45-2000 SSU (6 to 420 cSt)+250 °FPush and TwistC12-25000 psiNitileElectrical, ManualSolenoid operated, Manually operatedMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250 °F5 drops/min85% of rated voltage at 72°F (20°C) minNo5-7 lb-ftN/AYes0.29 kg5/8" Super Coil100 ms92-96 lb-ftNormally Closed5000 PSI, 350 BARNitrileElectrical, ManualNo24 GAL/MIN, 90 L/MIN
DSH121CRTV
Backordered
POR
N/A2-Way24 Gal/min350 barHydraulic Systems Division-15 °FSide to Nose (2-1)90 L/min45-2000 SSU (6 to 420 cSt)+204 °CPush and TwistC12-25000 psiFluorocarbonElectrical, ManualSolenoid operated, Manually operatedMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +400 °F5 drops/min85% of rated voltage at 72°F (20°C) minNo7-10 NmN/AYes0.29 kg5/8" Super Coil100 ms125-131 NmNormally Closed5000 PSI, 350 BARFluorocarbonElectrical, ManualNo24 GAL/MIN, 90 L/MIN
DSH121CRV
Backordered
$192.30
N/A2-Way90 L/min5000 psiHydraulic Systems Division-15 °FSide to Nose (2-1)90 L/min45-2000 SSU (6 to 420 cSt)+204 °Cn/aC12-2350 barFluorocarbonElectricalSolenoid OperatedMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +400 °F5 drops/min85% of rated voltage at 72°F (20°C) minNo5-7 lb-ftN/AYes0.29 kg5/8" Super Coil100 ms125-131 NmNormally Closed5000 PSI, 350 BARFluorocarbonElectricalNo24 GAL/MIN, 90 L/MIN
DSH121CT
5 in stock
$231.90
N/A2-Way24 Gal/min5000 psiHydraulic Systems Division-34 °CSide to Nose (2-1)90 L/min45-2000 SSU (6 to 420 cSt)+121 °CPush and TwistC12-2350 barNitileElectrical, ManualSolenoid operated, Manually operatedMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-34 to +121 °C5 drops/min85% of rated voltage at 72°F (20°C) minNo5-7 lb-ftN/ANo0.65 lb5/8" Super Coil100 ms92-96 lb-ftNormally Closed5000 PSI, 350 BARNitrileElectrical, ManualNo24 GAL/MIN, 90 L/MIN
DSH121CTV
Backordered
POR
N/A2-Way90 L/min350 barHydraulic Systems Division-26 °CSide to Nose (2-1)90 L/min45-2000 SSU (6 to 420 cSt)+204 °CPush and TwistC12-2350 barFluorocarbonElectrical, ManualSolenoid operated, Manually operatedMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-26 to +204 °C5 drops/min85% of rated voltage at 72°F (20°C) minNo7-10 NmN/ANo0.65 lb5/8" Super Coil100 ms92-96 lb-ftNormally Closed5000 PSI, 350 BARFluorocarbonElectrical, ManualNo24 GAL/MIN, 90 L/MIN
DSH121CV
Backordered
POR
N/A2-Way24 Gal/min350 barHydraulic Systems Division-26 °CSide to Nose (2-1)24 Gal/min45-2000 SSU (6 to 420 cSt)+204 °Cn/aC12-2350 barFluorocarbonElectricalSolenoid OperatedMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-26 to +204 °C5 drops/min85% of rated voltage at 72°F (20°C) minNo7-10 NmN/ANo0.29 kg5/8" Super Coil100 ms92-96 lb-ftNormally Closed5000 PSI, 350 BARFluorocarbonElectricalNo24 GAL/MIN, 90 L/MIN
DSH121N
14 in stock
$228.60
N/A2-Way90 L/min350 barHydraulic Systems Division-34 °CSide to Nose (2-1)90 L/min45-2000 SSU (6 to 420 cSt)+121 °Cn/aC12-2350 barNitileElectricalSolenoid OperatedMineral-based or synthetic hydraulic fluidsNormally OpenAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-34 to +121 °C5 drops/min85% of rated voltage at 72°F (20°C) minNo7-10 NmN/ANo0.65 lb5/8" Super Coil70 ms92-96 lb-ftNormally Open5000 PSI, 350 BARNitrileElectricalNo24 GAL/MIN, 90 L/MIN
DSH121NE
Backordered
POR
N/A2-Way90 L/min350 barHydraulic Systems Division-34 °CSide to Nose (2-1)24 Gal/min45-2000 SSU (6 to 420 cSt)+250 °FPush Type w/Extended RodC12-2350 barNitileElectrical, ManualSolenoid operated, Manually operatedMineral-based or synthetic hydraulic fluidsNormally OpenAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-34 to +121 °C5 drops/min85% of rated voltage at 72°F (20°C) minNo7-10 NmN/ANo0.65 lb5/8" Super Coil70 ms92-96 lb-ftNormally Open5000 PSI, 350 BARNitrileElectrical, ManualNo24 GAL/MIN, 90 L/MIN

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains