• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Cover
  • Division
  • For Fluid Type
  • Function
  • Input Voltage
  • Maximum Flow Rate
  • Maximum Operating Pressure
  • Maximum Operating Temperature
More Filters...

2/2-Way Seat Valve for Subplate Mounting - Series D4S

Picture for category 2/2-Way Seat Valve for Subplate Mounting - Series D4S

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's highly versatile 2/2-way seat valves series D4S for subplate mounting are designed for directional control functions and feature numerous options. A large variety of poppets, springs and covers – including shuttle valves, stroke limiters, solenoid valves (VV01) and position control – allows to design individual hydraulic solutions for nominal flow up to 600 l/min.

Markets:
• Industrial

Features/Benefits:
• Proven, robust design - ensures reliable operation
• Individual configurability, various function options - useable for numerous applications
• Good price-performance ratio - fast return of investment
• Short delivery time - no warehousing necessary
• Subplate mounting according to ISO 5781
• Leak-free seat valve design
• Numerous pilot options
• 6 poppet types:
    - D4S03 - NG10
    - D4S06 - NG25
    - D4S10 - NG32

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceWeightBody MaterialMounting TypeSeal MaterialActuation TypeFor Fluid TypeProduct SeriesMaximum Flow RateDivisionMaximum Operating PressureMaximum Operating TemperatureMinimum Operating TemperatureFunctionMounting PositionInput VoltageSeal MaterialPort ConnectionSwitching OptionPilot Inlet / Drain LocationsCoverOptionsSpool TypeSleeve TypeMinimum Opening Pressure
026-38900-T
Backordered
POR
6 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Unrestricted110/120 (VAC), 50/60 (Hz)NBRNG32 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: External from X (A-X closed / B-Y closed)Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 bar
026-39583-0
Backordered
POR
6 kgCast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °Cn/aUnrestrictednaNBRNG32 / ISO 6264N/APilot line body: Internal from B (A-X closed / B-Y orifice 1.2)Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 bar
026-39923-0
Backordered
POR
2.7 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve180 L/minIndustrial Systems Division Europe350 bar60 °C-20 °Cn/aUnrestrictednaNBRNG10 / ISO 6264N/APilot line body: External from X (A-X closed / B-Y open)Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACA-B 1.2 bar
026-41155-H
Backordered
POR
2.7 kgCast IronSubplateFPMSolenoidWater-GlycolCheck Valve180 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Unrestricted24 (VDC)FPMNG10 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: External from X (A-X closed / B-Y closed)Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 4.0 bar, B-A 5.5 bar
026-41558-H
Backordered
POR
2.7 kgCast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve180 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid not activated, unpressurized circulation, with manual override.Unrestricted24 (VDC)NBRNG10 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 4.0 bar, B-A 5.5 bar
026-41998-H
Backordered
POR
6 kgCast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Unrestricted24 (VDC)NBRNG32 / ISO 6264Shuttle valve Z-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
026-42112-H
Backordered
POR
4.5 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CShuttle Valve Z-YUnrestricted24 (VDC)NBRNG25 / ISO 6264Shuttle valve Z-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
026-42158-H
Backordered
POR
2.7 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve180 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Unrestricted24 (VDC)NBRNG10 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
026-42372-H
Backordered
POR
4.5 kgCast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Unrestricted24 (VDC)NBRNG25 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: External from X (A-X closed / B-Y closed)Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 bar
026-43227-U
Backordered
POR
6 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Unrestricted230/240 (VAC), 50/60 (Hz)NBRNG32 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 bar
026-43591-T
Backordered
POR
6 kgCast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Unrestricted110/120 (VAC), 50/60 (Hz)NBRNG32 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
026-46517-H
Backordered
POR
6 kgCast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Unrestricted24 (VDC)NBRNG32 / ISO 6264Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
026-46891-H
Backordered
POR
2.7 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve180 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Unrestricted24 (VDC)NBRNG10 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
026-47839-H
Backordered
POR
2.7 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve180 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Unrestricted24 (VDC)NBRNG10 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: External from X (A-X closed / B-Y closed)Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 4.0 bar, B-A 5.5 bar
026-48039-H
Backordered
POR
6 kgCast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid not activated, unpressurized circulation, with manual override.Unrestricted24 (VDC)NBRNG32 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Pilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACA-B 0.5 bar
026-48163-T
Backordered
POR
2.7 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve180 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Unrestricted110/120 (VAC), 50/60 (Hz)NBRNG10 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
026-52283-H
Backordered
POR
4.5 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Unrestricted24 (VDC)NBRNG25 / ISO 6264Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
026-53704-0
Backordered
POR
4.5 kgCast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °Cn/aUnrestrictednaNBRNG25 / ISO 6264N/APilot line body: Internal from B (A-X closed / B-Y orifice 1.2)Pilot line cap: With stroke limiter, pilot oil = pilot drain, X closed, Y orifice 1.2N/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
026-53788-H
Backordered
POR
6 kgCast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Unrestricted24 (VDC)NBRNG32 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
026-53965-H
Backordered
POR
4.5 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Unrestricted24 (VDC)NBRNG25 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains