• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Cover
  • Division
  • For Fluid Type
  • Function
  • Input Voltage
  • Maximum Flow Rate
  • Maximum Operating Pressure
  • Maximum Operating Temperature
More Filters...

2/2-Way Seat Valve for Subplate Mounting - Series D4S

Picture for category 2/2-Way Seat Valve for Subplate Mounting - Series D4S

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's highly versatile 2/2-way seat valves series D4S for subplate mounting are designed for directional control functions and feature numerous options. A large variety of poppets, springs and covers – including shuttle valves, stroke limiters, solenoid valves (VV01) and position control – allows to design individual hydraulic solutions for nominal flow up to 600 l/min.

Markets:
• Industrial

Features/Benefits:
• Proven, robust design - ensures reliable operation
• Individual configurability, various function options - useable for numerous applications
• Good price-performance ratio - fast return of investment
• Short delivery time - no warehousing necessary
• Subplate mounting according to ISO 5781
• Leak-free seat valve design
• Numerous pilot options
• 6 poppet types:
    - D4S03 - NG10
    - D4S06 - NG25
    - D4S10 - NG32

Applications:
• Suitable for general hydraulic applications
Read More...
Sort by
Display per page
ActionSKUAvailabilityPriceWeightFunctionBody MaterialMounting TypeSeal MaterialActuation TypeFor Fluid TypeProduct SeriesMaximum Flow RateMounting PositionDivisionMaximum Operating PressureMaximum Operating TemperatureMinimum Operating TemperatureCoverOptionsSpool TypeSleeve TypeInput VoltageSeal MaterialPort ConnectionSwitching OptionMinimum Opening PressurePilot Inlet / Drain Locations
026-56111-H
Backordered
POR
2.7 kgShuttle Valve X-YCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve180 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 AC24 (VDC)NBRNG10 / ISO 6264Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overrideA-B 4.0 bar, B-A 5.5 barPilot line body: External from X (A-X closed / B-Y open)
026-56157-0
Backordered
POR
4.5 kgPosition Control with amplifierCast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve360 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedCover for end position controlPoppet with safety spoolAA=0.60 AC, AB=0.40 ACnaNBRNG25 / ISO 6264Position control, with amplifierA-B 3.5 bar, B-A 6.0 barPilot line body: External from X (A-X closed / B-Y open)
026-56807-H
Backordered
POR
6 kgVent Function Solenoid not activated, unpressurized circulation, with manual override.Cast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve360 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 AC24 (VDC)NBRNG32 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual overrideA-B 3.5 bar, B-A 6.0 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)
026-57539-H
Backordered
POR
4.5 kgVent Function Solenoid not activated, unpressurized circulation, with manual override.Cast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve360 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 AC24 (VDC)NBRNG25 / ISO 6264Shuttle valve X-Y and vent function: Solenoid not activated, unpressurized circulation, with manual overrideA-B 3.5 bar, B-A 6.0 barPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
026-62482-H
Backordered
POR
4.5 kgVent Function Solenoid activated, unpressurized circulation, with manual override.Cast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve360 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 AC24 (VDC)NBRNG25 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overrideA-B 3.5 bar, B-A 6.0 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)
026-65920-H
Backordered
POR
2.7 kgVent Function Solenoid not activated, unpressurized circulation, with manual override.Cast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve180 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 AC24 (VDC)NBRNG10 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual overrideA-B 4.0 bar, B-A 5.5 barPilot line body: External from X (A-X closed / B-Y closed)
026-66063-T
Backordered
POR
6 kgVent Function Solenoid activated, unpressurized circulation, with manual override.Cast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve600 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 AC110/120 (VAC), 50/60 (Hz)NBRNG32 / ISO 6264Shuttle valve Z-Y and vent function: Solenoid activated, unpressurized circulation, with manual overrideA-B 2.2 barPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
026-66064-T
Backordered
POR
6 kgVent Function Solenoid not activated, unpressurized circulation, with manual override.Cast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve600 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 AC110/120 (VAC), 50/60 (Hz)NBRNG32 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual overrideA-B 2.2 bar, B-A 3.8 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)
026-66065-T
Backordered
POR
6 kgVent Function Solenoid activated, unpressurized circulation, with manual override.Cast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve600 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with throttle spool, 3° chamferAA=0.60 AC, AB=0.40 AC110/120 (VAC), 50/60 (Hz)NBRNG32 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overrideA-B 3.5 bar, B-A 6.0 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)
026-66316-H
Backordered
POR
6 kgVent Function Solenoid activated, unpressurized circulation, with manual override.Cast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve600 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 AC24 (VDC)NBRNG32 / ISO 6264Shuttle valve Z-Y and vent function: Solenoid activated, unpressurized circulation, with manual overrideA-B 0.6 bar, B-A 0.9 barPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
026-66353-0
Backordered
POR
6 kgn/aCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve600 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: Standard, pilot oil = pilot drain, X closed, Y open, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACnaNBRNG32 / ISO 6264N/AA-B 2.2 barPilot line body: External from Y (A-X orifice 1.2 / B-Y open)
026-66426-H
Backordered
POR
4.5 kgVent Function Solenoid activated, unpressurized circulation, with manual override.Cast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve360 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 AC24 (VDC)NBRNG25 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overrideA-B 2.2 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)
026-66602-0
Backordered
POR
4.5 kgShuttle Valve Z-YCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve360 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACnaNBRNG25 / ISO 6264Shuttle valve Z-YA-B 2.2 barPilot line body: Internal from B (A-X closed / B-Y orifice 1.2)
026-66827-T
Backordered
POR
2.7 kgVent Function Solenoid not activated, unpressurized circulation, with manual override.Cast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve180 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 AC110/120 (VAC), 50/60 (Hz)NBRNG10 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual overrideA-B 2.2 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)
026-66963-H
Backordered
POR
4.5 kgVent Function Solenoid activated, unpressurized circulation, with manual override.Cast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve360 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 AC24 (VDC)NBRNG25 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overrideA-B 3.5 bar, B-A 6.0 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)
026-67128-H
Backordered
POR
2.7 kgVent Function Solenoid not activated, unpressurized circulation, with manual override.Cast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve180 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 AC24 (VDC)NBRNG10 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual overrideA-B 2.2 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)
026-67252-0
Backordered
POR
2.7 kgn/aCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve180 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACnaNBRNG10 / ISO 6264N/AA-B 0.6 bar, B-A 0.9 barPilot line body: External from X (A-X closed / B-Y closed)
026-67435-S
Backordered
POR
2.7 kgVent Function Solenoid activated, unpressurized circulation, with manual override.Cast IronSubplateFPMSolenoidWater-GlycolCheck Valve180 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 AC230/240 (VAC), 50/60 (Hz)FPMNG10 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overrideA-B 4.0 bar, B-A 5.5 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)
026-67436-S
Backordered
POR
2.7 kgShuttle Valve X-YCast IronSubplateFPMSolenoidWater-GlycolCheck Valve180 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 AC230/240 (VAC), 50/60 (Hz)FPMNG10 / ISO 6264Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overrideA-B 4.0 bar, B-A 5.5 barPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
026-67640-U
Backordered
POR
4.5 kgVent Function Solenoid not activated, unpressurized circulation, with manual override.Cast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve360 L/minUnrestrictedIndustrial Systems Division Europe350 bar60 °C-20 °CPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 AC230/240 (VAC), 50/60 (Hz)NBRNG25 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual overrideA-B 2.2 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains