*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Action | SKU | Availability | Price | Weight | Function | Body Material | Mounting Type | Seal Material | Actuation Type | For Fluid Type | Product Series | Maximum Flow Rate | Mounting Position | Division | Maximum Operating Pressure | Maximum Operating Temperature | Minimum Operating Temperature | Cover | Options | Spool Type | Sleeve Type | Input Voltage | Seal Material | Port Connection | Switching Option | Minimum Opening Pressure | Pilot Inlet / Drain Locations |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
026-56111-H | Backordered | POR | 2.7 kg | Shuttle Valve X-Y | Cast Iron | Subplate | NBR | Pilot | Hydraulic Oil According to DIN 51524 | Check Valve | 180 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed | N/A | Poppet with closed bottom, 45° chamfer | AA=0.60 AC, AB=0.40 AC | 24 (VDC) | NBR | NG10 / ISO 6264 | Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual override | A-B 4.0 bar, B-A 5.5 bar | Pilot line body: External from X (A-X closed / B-Y open) | |
026-56157-0 | Backordered | POR | 4.5 kg | Position Control with amplifier | Cast Iron | Subplate | NBR | Solenoid | Hydraulic Oil According to DIN 51524 | Check Valve | 360 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closed | Cover for end position control | Poppet with safety spool | AA=0.60 AC, AB=0.40 AC | na | NBR | NG25 / ISO 6264 | Position control, with amplifier | A-B 3.5 bar, B-A 6.0 bar | Pilot line body: External from X (A-X closed / B-Y open) | |
026-56807-H | Backordered | POR | 6 kg | Vent Function Solenoid not activated, unpressurized circulation, with manual override. | Cast Iron | Subplate | NBR | Solenoid | Hydraulic Oil According to DIN 51524 | Check Valve | 360 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed | N/A | Poppet with closed bottom, 45° chamfer | AA=0.60 AC, AB=0.40 AC | 24 (VDC) | NBR | NG32 / ISO 6264 | Vent function: Solenoid not activated, unpressurized circulation, with manual override | A-B 3.5 bar, B-A 6.0 bar | Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open) | |
026-57539-H | Backordered | POR | 4.5 kg | Vent Function Solenoid not activated, unpressurized circulation, with manual override. | Cast Iron | Subplate | NBR | Pilot | Hydraulic Oil According to DIN 51524 | Check Valve | 360 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed | N/A | Poppet with closed bottom, 45° chamfer | AA=0.60 AC, AB=0.40 AC | 24 (VDC) | NBR | NG25 / ISO 6264 | Shuttle valve X-Y and vent function: Solenoid not activated, unpressurized circulation, with manual override | A-B 3.5 bar, B-A 6.0 bar | Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2) | |
026-62482-H | Backordered | POR | 4.5 kg | Vent Function Solenoid activated, unpressurized circulation, with manual override. | Cast Iron | Subplate | NBR | Pilot | Hydraulic Oil According to DIN 51524 | Check Valve | 360 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed | N/A | Poppet with closed bottom, 45° chamfer | AA=0.60 AC, AB=0.40 AC | 24 (VDC) | NBR | NG25 / ISO 6264 | Vent function: solenoid activated, unpressurized circulation, with manual override | A-B 3.5 bar, B-A 6.0 bar | Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open) | |
026-65920-H | Backordered | POR | 2.7 kg | Vent Function Solenoid not activated, unpressurized circulation, with manual override. | Cast Iron | Subplate | NBR | Pilot | Hydraulic Oil According to DIN 51524 | Check Valve | 180 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open | N/A | Poppet with closed bottom, 45° chamfer | AA=0.60 AC, AB=0.40 AC | 24 (VDC) | NBR | NG10 / ISO 6264 | Vent function: Solenoid not activated, unpressurized circulation, with manual override | A-B 4.0 bar, B-A 5.5 bar | Pilot line body: External from X (A-X closed / B-Y closed) | |
026-66063-T | Backordered | POR | 6 kg | Vent Function Solenoid activated, unpressurized circulation, with manual override. | Cast Iron | Subplate | NBR | Solenoid | Hydraulic Oil According to DIN 51524 | Check Valve | 600 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed | N/A | Poppet with closed bottom, 45° chamfer | AA=0.95 AC, AB=0.05 AC | 110/120 (VAC), 50/60 (Hz) | NBR | NG32 / ISO 6264 | Shuttle valve Z-Y and vent function: Solenoid activated, unpressurized circulation, with manual override | A-B 2.2 bar | Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2) | |
026-66064-T | Backordered | POR | 6 kg | Vent Function Solenoid not activated, unpressurized circulation, with manual override. | Cast Iron | Subplate | NBR | Solenoid | Hydraulic Oil According to DIN 51524 | Check Valve | 600 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed | N/A | Poppet with closed bottom, 45° chamfer | AA=0.60 AC, AB=0.40 AC | 110/120 (VAC), 50/60 (Hz) | NBR | NG32 / ISO 6264 | Vent function: Solenoid not activated, unpressurized circulation, with manual override | A-B 2.2 bar, B-A 3.8 bar | Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open) | |
026-66065-T | Backordered | POR | 6 kg | Vent Function Solenoid activated, unpressurized circulation, with manual override. | Cast Iron | Subplate | NBR | Pilot | Hydraulic Oil According to DIN 51524 | Check Valve | 600 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open | N/A | Poppet with throttle spool, 3° chamfer | AA=0.60 AC, AB=0.40 AC | 110/120 (VAC), 50/60 (Hz) | NBR | NG32 / ISO 6264 | Vent function: solenoid activated, unpressurized circulation, with manual override | A-B 3.5 bar, B-A 6.0 bar | Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open) | |
026-66316-H | Backordered | POR | 6 kg | Vent Function Solenoid activated, unpressurized circulation, with manual override. | Cast Iron | Subplate | NBR | Pilot | Hydraulic Oil According to DIN 51524 | Check Valve | 600 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed | N/A | Poppet with closed bottom, 45° chamfer | AA=0.60 AC, AB=0.40 AC | 24 (VDC) | NBR | NG32 / ISO 6264 | Shuttle valve Z-Y and vent function: Solenoid activated, unpressurized circulation, with manual override | A-B 0.6 bar, B-A 0.9 bar | Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2) | |
026-66353-0 | Backordered | POR | 6 kg | n/a | Cast Iron | Subplate | NBR | Pilot | Hydraulic Oil According to DIN 51524 | Check Valve | 600 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: Standard, pilot oil = pilot drain, X closed, Y open, Z orifice 1.2, X-Y open, Y1 closed | N/A | Poppet with closed bottom, 45° chamfer | AA=0.95 AC, AB=0.05 AC | na | NBR | NG32 / ISO 6264 | N/A | A-B 2.2 bar | Pilot line body: External from Y (A-X orifice 1.2 / B-Y open) | |
026-66426-H | Backordered | POR | 4.5 kg | Vent Function Solenoid activated, unpressurized circulation, with manual override. | Cast Iron | Subplate | NBR | Pilot | Hydraulic Oil According to DIN 51524 | Check Valve | 360 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open | N/A | Poppet with closed bottom, 45° chamfer | AA=0.95 AC, AB=0.05 AC | 24 (VDC) | NBR | NG25 / ISO 6264 | Vent function: solenoid activated, unpressurized circulation, with manual override | A-B 2.2 bar | Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open) | |
026-66602-0 | Backordered | POR | 4.5 kg | Shuttle Valve Z-Y | Cast Iron | Subplate | NBR | Pilot | Hydraulic Oil According to DIN 51524 | Check Valve | 360 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closed | N/A | Poppet with closed bottom, 45° chamfer | AA=0.95 AC, AB=0.05 AC | na | NBR | NG25 / ISO 6264 | Shuttle valve Z-Y | A-B 2.2 bar | Pilot line body: Internal from B (A-X closed / B-Y orifice 1.2) | |
026-66827-T | Backordered | POR | 2.7 kg | Vent Function Solenoid not activated, unpressurized circulation, with manual override. | Cast Iron | Subplate | NBR | Pilot | Hydraulic Oil According to DIN 51524 | Check Valve | 180 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open | N/A | Poppet with closed bottom, 45° chamfer | AA=0.95 AC, AB=0.05 AC | 110/120 (VAC), 50/60 (Hz) | NBR | NG10 / ISO 6264 | Vent function: Solenoid not activated, unpressurized circulation, with manual override | A-B 2.2 bar | Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open) | |
026-66963-H | Backordered | POR | 4.5 kg | Vent Function Solenoid activated, unpressurized circulation, with manual override. | Cast Iron | Subplate | NBR | Solenoid | Hydraulic Oil According to DIN 51524 | Check Valve | 360 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open | N/A | Poppet with closed bottom, 45° chamfer | AA=0.60 AC, AB=0.40 AC | 24 (VDC) | NBR | NG25 / ISO 6264 | Vent function: solenoid activated, unpressurized circulation, with manual override | A-B 3.5 bar, B-A 6.0 bar | Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open) | |
026-67128-H | Backordered | POR | 2.7 kg | Vent Function Solenoid not activated, unpressurized circulation, with manual override. | Cast Iron | Subplate | NBR | Pilot | Hydraulic Oil According to DIN 51524 | Check Valve | 180 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open | N/A | Poppet with closed bottom, 15° chamfer | AA=0.95 AC, AB=0.05 AC | 24 (VDC) | NBR | NG10 / ISO 6264 | Vent function: Solenoid not activated, unpressurized circulation, with manual override | A-B 2.2 bar | Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed) | |
026-67252-0 | Backordered | POR | 2.7 kg | n/a | Cast Iron | Subplate | NBR | Pilot | Hydraulic Oil According to DIN 51524 | Check Valve | 180 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closed | N/A | Poppet with closed bottom, 45° chamfer | AA=0.60 AC, AB=0.40 AC | na | NBR | NG10 / ISO 6264 | N/A | A-B 0.6 bar, B-A 0.9 bar | Pilot line body: External from X (A-X closed / B-Y closed) | |
026-67435-S | Backordered | POR | 2.7 kg | Vent Function Solenoid activated, unpressurized circulation, with manual override. | Cast Iron | Subplate | FPM | Solenoid | Water-Glycol | Check Valve | 180 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open | N/A | Poppet with closed bottom, 45° chamfer | AA=0.60 AC, AB=0.40 AC | 230/240 (VAC), 50/60 (Hz) | FPM | NG10 / ISO 6264 | Vent function: solenoid activated, unpressurized circulation, with manual override | A-B 4.0 bar, B-A 5.5 bar | Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open) | |
026-67436-S | Backordered | POR | 2.7 kg | Shuttle Valve X-Y | Cast Iron | Subplate | FPM | Solenoid | Water-Glycol | Check Valve | 180 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed | N/A | Poppet with closed bottom, 45° chamfer | AA=0.60 AC, AB=0.40 AC | 230/240 (VAC), 50/60 (Hz) | FPM | NG10 / ISO 6264 | Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual override | A-B 4.0 bar, B-A 5.5 bar | Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2) | |
026-67640-U | Backordered | POR | 4.5 kg | Vent Function Solenoid not activated, unpressurized circulation, with manual override. | Cast Iron | Subplate | NBR | Pilot | Hydraulic Oil According to DIN 51524 | Check Valve | 360 L/min | Unrestricted | Industrial Systems Division Europe | 350 bar | 60 °C | -20 °C | Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open | N/A | Poppet with closed bottom, 15° chamfer | AA=0.95 AC, AB=0.05 AC | 230/240 (VAC), 50/60 (Hz) | NBR | NG25 / ISO 6264 | Vent function: Solenoid not activated, unpressurized circulation, with manual override | A-B 2.2 bar | Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed) |
REWARD Status
Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.