• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Cover
  • Division
  • For Fluid Type
  • Function
  • Input Voltage
  • Maximum Flow Rate
  • Maximum Operating Pressure
  • Maximum Operating Temperature
More Filters...

2/2-Way Seat Valve for Subplate Mounting - Series D4S

Picture for category 2/2-Way Seat Valve for Subplate Mounting - Series D4S

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's highly versatile 2/2-way seat valves series D4S for subplate mounting are designed for directional control functions and feature numerous options. A large variety of poppets, springs and covers – including shuttle valves, stroke limiters, solenoid valves (VV01) and position control – allows to design individual hydraulic solutions for nominal flow up to 600 l/min.

Markets:
• Industrial

Features/Benefits:
• Proven, robust design - ensures reliable operation
• Individual configurability, various function options - useable for numerous applications
• Good price-performance ratio - fast return of investment
• Short delivery time - no warehousing necessary
• Subplate mounting according to ISO 5781
• Leak-free seat valve design
• Numerous pilot options
• 6 poppet types:
    - D4S03 - NG10
    - D4S06 - NG25
    - D4S10 - NG32

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceWeightBody MaterialMounting TypeSeal MaterialActuation TypeProduct SeriesMaximum Flow RateDivisionMaximum Operating PressureMaximum Operating TemperatureMinimum Operating TemperatureFunctionFor Fluid TypeMounting PositionInput VoltageSeal MaterialPort ConnectionPilot Inlet / Drain LocationsCoverOptionsSpool TypeSleeve TypeSwitching OptionMinimum Opening Pressure
026-67821-H
Backordered
POR
6 kgCast IronSubplateNBRPilotCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Hydraulic Oil According to DIN 51524Unrestricted24 (VDC)NBRNG32 / ISO 6264Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACShuttle valve Z-Y and vent function: Solenoid activated, unpressurized circulation, with manual overrideA-B 3.5 bar, B-A 6.0 bar
026-67949-0
Backordered
POR
4.5 kgCast IronSubplateNBRPilotCheck Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °Cn/aHydraulic Oil According to DIN 51524UnrestrictednaNBRNG25 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Pilot line cap: With stroke limiter, pilot oil = pilot drain, X orifice 1.2, Y closedN/APoppet with throttle spool, 10° chamferAA=0.60 AC, AB=0.40 ACN/AA-B 2.2 bar, B-A 3.8 bar
026-70909-H
Backordered
POR
6 kgCast IronSubplateNBRPilotCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CShuttle Valve X-YHydraulic Oil According to DIN 51524Unrestricted24 (VDC)NBRNG32 / ISO 6264Pilot line body: Internal from B (A-X closed / B-Y orifice 1.2)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACShuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overrideA-B 0.6 BAR, B-A 1.0 BAR
026-70949-H
Backordered
POR
6 kgCast IronSubplateNBRPilotCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Hydraulic Oil According to DIN 51524Unrestricted24 (VDC)NBRNG32 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACVent function: solenoid activated, unpressurized circulation, with manual overrideA-B 16.0 bar, B-A 28.0 bar
026-70976-H
Backordered
POR
6 kgCast IronSubplateNBRPilotCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Hydraulic Oil According to DIN 51524Unrestricted24 (VDC)NBRNG32 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACVent function: solenoid activated, unpressurized circulation, with manual overrideA-B 3.5 bar, B-A 6.0 bar
026-75836-T
Backordered
POR
4.5 kgCast IronSubplateNBRPilotCheck Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Hydraulic Oil According to DIN 51524Unrestricted110/120 (VAC), 50/60 (Hz)NBRNG25 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACVent function: solenoid activated, unpressurized circulation, with manual overrideA-B 2.2 bar
026-95556-H
Backordered
POR
4.5 kgCast IronSubplateFPMSolenoidCheck Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Water-GlycolUnrestricted24 (VDC)FPMNG25 / ISO 6264Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACShuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overrideA-B 3.5 bar, B-A 6.0 bar
026-96259-0
Backordered
POR
6 kgCast IronSubplateNBRPilotCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °Cn/aHydraulic Oil According to DIN 51524UnrestrictednaNBRNG32 / ISO 6264Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACN/AA-B 3.5 bar, B-A 6.0 bar
026-96484-H
Backordered
POR
6 kgCast IronSubplateNBRSolenoidCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Hydraulic Oil According to DIN 51524Unrestricted24 (VDC)NBRNG32 / ISO 6264Pilot line body: Internal from B (A-X closed / B-Y orifice 1.2)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACShuttle valve Z-Y and vent function: Solenoid activated, unpressurized circulation, with manual overrideA-B 3.5 bar, B-A 6.0 bar
026-96516-H
Backordered
POR
4.5 kgCast IronSubplateNBRSolenoidCheck Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CPosition Control and Vent Function Solenoid activated, unpressurized circulation, without manual override, with amplifier.Hydraulic Oil According to DIN 51524Unrestricted24 (VDC)NBRNG25 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with safety spoolAA=0.60 AC, AB=0.40 ACPosition control and vent function: Solenoid activated, unpressurized circulation, without manual override, with amplifierA-B 1 bar, B-A 1.7 bar
026-96518-H
Backordered
POR
6 kgCast IronSubplateNBRPilotCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CPosition Control and Vent Function Solenoid activated, unpressurized circulation, without manual override, with amplifier.Hydraulic Oil According to DIN 51524Unrestricted24 (VDC)NBRNG32 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with safety spoolAA=0.60 AC, AB=0.40 ACPosition control and vent function: Solenoid activated, unpressurized circulation, without manual override, with amplifierA-B 0.6 BAR, B-A 1.0 BAR
026-96673-0
Backordered
POR
2.7 kgCast IronSubplateNBRPilotCheck Valve180 L/minIndustrial Systems Division Europe350 bar60 °C-20 °Cn/aHydraulic Oil According to DIN 51524UnrestrictednaNBRNG10 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACN/AA-B 3.0 bar
026-99107-T
Backordered
POR
6 kgCast IronSubplateNBRSolenoidCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid not activated, unpressurized circulation, with manual override.Hydraulic Oil According to DIN 51524Unrestricted110/120 (VAC), 50/60 (Hz)NBRNG32 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACVent function: Solenoid not activated, unpressurized circulation, with manual overrideA-B 0.6 BAR, B-A 1.0 BAR
026-99402-0
Backordered
POR
4.5 kgCast IronSubplateNBRSolenoidCheck Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °Cn/aHydraulic Oil According to DIN 51524UnrestrictednaNBRNG25 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)Pilot line cap: With stroke limiter, pilot oil = pilot drain, X orifice 1.2, Y closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACN/AA-B 1 bar, B-A 1.7 bar
026-99453-0
Backordered
POR
4.5 kgCast IronSubplateNBRSolenoidCheck Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °Cn/aHydraulic Oil According to DIN 51524UnrestrictednaNBRNG25 / ISO 6264Pilot line body: External from X (A-X closed / B-Y closed)Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with throttle spool, 10° chamferAA=0.60 AC, AB=0.40 ACN/AA-B 2.2 bar, B-A 3.8 bar
026-99487-0
Backordered
POR
6 kgCast IronSubplateNBRSolenoidCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °Cn/aHydraulic Oil According to DIN 51524UnrestrictednaNBRNG32 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)Pilot line cap: With stroke limiter, pilot oil = pilot drain, X orifice 1.2, Y closedN/APoppet with throttle spool, 3° chamferAA=0.60 AC, AB=0.40 ACN/AA-B 3.5 bar, B-A 6.0 bar
026-99492-H
Backordered
POR
6 kgCast IronSubplateFPMPilotCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.Water-GlycolUnrestricted24 (VDC)FPMNG32 / ISO 6264Pilot line body: Internal from B (A-X closed / B-Y orifice 1.2)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACShuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overrideA-B 3.5 bar, B-A 6.0 bar
026-99697-H
Backordered
POR
6 kgCast IronSubplateNBRSolenoidCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CPosition Control and Vent Function Solenoid activated, unpressurized circulation, without manual override, with amplifier.Hydraulic Oil According to DIN 51524Unrestricted24 (VDC)NBRNG32 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openCover for end position controlPoppet with safety spoolAA=0.60 AC, AB=0.40 ACPosition control and vent function: Solenoid activated, unpressurized circulation, without manual override, with amplifierA-B 2.2 bar, B-A 3.8 bar
026-99808-0
Backordered
POR
4.5 kgCast IronSubplateNBRSolenoidCheck Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °Cn/aHydraulic Oil According to DIN 51524UnrestrictednaNBRNG25 / ISO 6264Pilot line body: External from X (A-X closed / B-Y closed)Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACN/AA-B 0.5 bar
056-40120-0
Backordered
POR
4.5 kgCast IronSubplateNBRSolenoidCheck Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °Cn/aHydraulic Oil According to DIN 51524UnrestrictednaNBRNG25 / ISO 6264Pilot line body: Internal from B (A-X closed / B-Y orifice 1.2)Pilot line cap: Standard, pilot oil = pilot drain, X closed, Y open, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACN/AA-B 1 bar, B-A 1.7 bar