2/2-Way Seat Valve for Subplate Mounting - Series D4S

Picture for category 2/2-Way Seat Valve for Subplate Mounting - Series D4S

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's highly versatile 2/2-way seat valves series D4S for subplate mounting are designed for directional control functions and feature numerous options. A large variety of poppets, springs and covers – including shuttle valves, stroke limiters, solenoid valves (VV01) and position control – allows to design individual hydraulic solutions for nominal flow up to 600 l/min.

Markets:
• Industrial

Features/Benefits:
• Proven, robust design - ensures reliable operation
• Individual configurability, various function options - useable for numerous applications
• Good price-performance ratio - fast return of investment
• Short delivery time - no warehousing necessary
• Subplate mounting according to ISO 5781
• Leak-free seat valve design
• Numerous pilot options
• 6 poppet types:
    - D4S03 - NG10
    - D4S06 - NG25
    - D4S10 - NG32

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceDivisionMaximum Operating TemperatureMinimum Operating TemperatureMaximum Operating PressureMounting TypeSeal MaterialFor Fluid TypeWeightBody MaterialProduct SeriesMounting PositionActuation TypeMaximum Flow RateFunctionSeal MaterialOptionsSpool TypeSleeve TypePort ConnectionSwitching OptionCoverInput VoltageMinimum Opening PressurePilot Inlet / Drain Locations
056-40223-H
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedPilot180 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACNG10 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open24 (VDC)A-B 1.0 BAR, B-A 1.5 BARPilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)
056-40370-H
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateFPMWater-Glycol4.5 kgCast IronCheck ValveUnrestrictedSolenoid360 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.FPMN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACNG25 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 opennaA-B 0.6 BAR, B-A 1.0 BARPilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)
056-40431-B
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515244.5 kgCast IronCheck ValveUnrestrictedPilot360 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACNG25 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closed110/120 (VAC), 50/60 (Hz)A-B 3.5 bar, B-A 6.0 barPilot line body: External from X (A-X closed / B-Y closed)
056-40569-H
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515246 kgCast IronCheck ValveUnrestrictedPilot600 L/minPosition ControlNBRN/APoppet with safety spoolAA=0.60 AC, AB=0.40 ACNG32 / ISO 6264Shuttle valve X-Y, position control and vent function: Solenoid not activated, unpressurized circulation, without manual override, with amplifierPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed24 (VDC)A-B 3.5 bar, B-A 6.0 barPilot line body: Internal from B (A-X closed / B-Y orifice 1.2)
056-40645-0
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedSolenoid180 L/minn/aNBRN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACNG10 / ISO 6264N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closednaA-B 0.6 bar, B-A 0.9 barPilot line body: External from X (A-X closed / B-Y open)
D4S03-91114409G0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedSolenoid180 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACNG10 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closed24 (VDC)A-B 2.2 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)
D4S03-91614109G0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedSolenoid180 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACNG10 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open24 (VDC)A-B 2.8 BARPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)
D4S03-921114B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedPilot180 L/minn/aNBRN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACNG10 / ISO 6264N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closednaA-B 2.2 barPilot line body: External from X (A-X closed / B-Y open)
D4S03-921144B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedPilot180 L/minn/aNBRN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACNG10 / ISO 6264N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closednaA-B 2.2 barPilot line body: External from X (A-X closed / B-Y open)
D4S03-921342B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedSolenoid180 L/minn/aNBRN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACNG10 / ISO 6264N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closednaA-B 1.0 BAR, B-A 1.5 BARPilot line body: External from X (A-X closed / B-Y open)
D4S03-921342B5
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateFPMWater-Glycol2.7 kgCast IronCheck ValveUnrestrictedPilot180 L/minn/aFPMN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACNG10 / ISO 6264N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closednaA-B 1.0 BAR, B-A 1.5 BARPilot line body: External from X (A-X closed / B-Y open)
D4S03-921346B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedPilot180 L/minn/aNBRN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACNG10 / ISO 6264N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closednaA-B 2.0 bar, A-B 3.0 barPilot line body: External from X (A-X closed / B-Y open)
D4S03-92211411G0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedSolenoid180 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACNG10 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed24 (VDC)A-B 2.2 barPilot line body: External from X (A-X closed / B-Y open)
D4S03-9A211409G0QB1
Backordered
POR
Hydraulic Valve Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedPilot180 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRNAPoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACNG10 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed24 (VDC)A-B 2.2 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)
D4S03-9A211411G0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedSolenoid180 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACNG10 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed24 (VDC)A-B 2.2 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)
D4S03-9A214411W31B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedSolenoid180 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACNG10 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed230/240 (VAC), 50/60 (Hz)A-B 2.2 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)
D4S03-9A234209G0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedPilot180 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACNG10 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed24 (VDC)A-B 1.0 BAR, B-A 1.5 BARPilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)
D4S03-9B534311G0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedSolenoid180 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACNG10 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 open24 (VDC)A-B 0.6 bar, B-A 0.9 barPilot line body: External from X (A-X closed / B-Y closed)
D4S03-9C2141CDW31B1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedPilot180 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACNG10 / ISO 6264Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed230/240 (VAC), 50/60 (Hz)A-B 2.8 BARPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
D4S03-9C2344CDG0QB1
Backordered
POR
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBRHydraulic Oil According to DIN 515242.7 kgCast IronCheck ValveUnrestrictedPilot180 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACNG10 / ISO 6264Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closed24 (VDC)A-B 4.0 bar, B-A 5.5 barPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.