*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Action | SKU | Availability | Price | Function | Body Material | Seal Material | Specifications Met | Division | Port Size | Installation | Orifice Size | Configuration | Input Voltage | Actuation Type | Power Consumption | Main Flow Coefficient | Coil Specifications Met | Exhaust Flow Coefficient | Maximum Fluid Temperature | Preventive Maintenance Kit | Maximum Ambient Temperature | Maximum Pressure Differential | Minimum Pressure Differential | Voltage | Function | Coil Type | Body Material | Configuration | Seal Material | Port Size (inch) | Orifice Size (inch) | Minimum Pressure Differential (psi) | Maximum Operating Pressure Differential (psig) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
20LC06QN7 | Backordered | POR | 2-Way | Lead-Free Brass | NBR | - | Fluid Control Division | NPT 3/8 inch | IOM7220 | 5/32 inch | All Ports in Body | Pressure Vessel Only (AC or DC Voltage) | Direct Acting | 10 W | 0.43 Cv | Requires G7 Series Coil Kit | n/a | 185 °F | 7R004 | 150 °F | 230 psig (AC) | 0 psi | Pressure Vessel Only (AC or DC Voltage) | 2-Way | Requires G7 Series Coil Kit | Lead-Free Brass | Normally Closed | NBR | 3/8 NPT | 5/32 | 0 | 230 (AC) / 85 (DC) | |
20LC06QN7C7B | Backordered | POR | 2-Way | Lead-Free Brass | NBR | CULus Safety Shutoff | Fluid Control Division | NPT 3/8 inch | IOM7220 | 5/32 inch | All Ports in Body | 24.0 VDC | Direct Acting | 10 W | 0.43 Cv | IP69 | n/a | 185 °F | 7R004 | 150 °F | 85 psig | 0 psi | 24 VDC | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | Lead-Free Brass | Normally Closed | NBR | 3/8 NPT | 5/32 | 0 | 85 | |
20LC06QN7C7E | Backordered | POR | 2-Way | Lead-Free Brass | NBR | CULus Safety Shutoff | Fluid Control Division | NPT 3/8 inch | IOM7220 | 5/32 inch | Normally Closed (NC) | 24/60 | Direct Acting | 10 W | 0.43 Cv | IP69 | n/a | 185 °F | 7R004 | 150 °F | 230 psig | 0 psi | 24/60 | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | Lead-Free Brass | Normally Closed | NBR | 3/8 NPT | 5/32 | 0 | 230 | |
20LC06QN7C7F | Backordered | POR | 2-Way | Lead-Free Brass | NBR | CULus Safety Shutoff | Fluid Control Division | NPT 3/8 inch | IOM7220 | 5/32 inch | All Ports in Body | 120/60 VAC | Direct Acting | 10 W | 0.43 Cv | IP69 | n/a | 185 °F | 7R004 | 150 °F | 230 psig | 0 psi | 120/60, 110/50 | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | Lead-Free Brass | Normally Closed | NBR | 3/8 NPT | 5/32 | 0 | 230 | |
20LC06QN7D7B | Backordered | POR | 2-Way | Lead-Free Brass | NBR | CURus Safety Shutoff | Fluid Control Division | NPT 3/8 inch | IOM7220 | 5/32 inch | All Ports in Body | 24.0 VDC | Direct Acting | 10 W | 0.43 Cv | IP65 | n/a | 185 °F | 7R004 | 150 °F | 85 psig | 0 psi | 24 VDC | 2-Way | DIN 43650A / ISO 4400 | Lead-Free Brass | Normally Closed | NBR | 3/8 NPT | 5/32 | 0 | 85 | |
20LC06TN7 | Backordered | POR | 2-Way | Lead-Free Brass | NBR | - | Fluid Control Division | NPT 3/8 inch | IOM7220 | 7/32 inch | All Ports in Body | Pressure Vessel Only (AC or DC Voltage) | Direct Acting | 10 W | 0.79 Cv | Requires G7 Series Coil Kit | n/a | 185 °F | 7R004 | 150 °F | 110.0 psig (AC) | 0 psi | Pressure Vessel Only (AC or DC Voltage) | 2-Way | Requires G7 Series Coil Kit | Lead-Free Brass | Normally Closed | NBR | 3/8 NPT | 7/32 | 0 | 110 (AC) / 40 (DC) | |
20LC06TN7C7B | Backordered | POR | 2-Way | Lead-Free Brass | NBR | CULus Safety Shutoff | Fluid Control Division | NPT 3/8 inch | IOM7220 | 7/32 inch | All Ports in Body | 24.0 VDC | Direct Acting | 10 W | 0.79 Cv | IP69 | n/a | 185 °F | 7R004 | 150 °F | 40 psig | 0 psi | 24 VDC | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | Lead-Free Brass | Normally Closed | NBR | 3/8 NPT | 7/32 | 0 | 40 | |
20LC06TN7C7E | Backordered | POR | 2-Way | Lead-Free Brass | NBR | CULus Safety Shutoff | Fluid Control Division | NPT 3/8 inch | IOM7220 | 7/32 inch | All Ports in Body | 24/60 | Direct Acting | 10 W | 0.79 Cv | IP69 | n/a | 185 °F | 7R004 | 150 °F | 110 psig | 0 psi | 24/60 | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | Lead-Free Brass | Normally Closed | NBR | 3/8 NPT | 7/32 | 0 | 110 | |
20LC06TN7C7F | Backordered | POR | 2-Way | Lead-Free Brass | NBR | CULus Safety Shutoff | Fluid Control Division | NPT 3/8 inch | IOM7220 | 7/32 inch | All Ports in Body | 110/50 VAC | Direct Acting | 10 W | 0.79 Cv | IP69 | n/a | 185 °F | 7R004 | 150 °F | 110 psig | 0 psi | 120/60, 110/50 | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | Lead-Free Brass | Normally Closed | NBR | 3/8 NPT | 7/32 | 0 | 110 | |
20LC06TN7D7B | Backordered | POR | 2-Way | Lead-Free Brass | NBR | CURus Safety Shutoff | Fluid Control Division | NPT 3/8 inch | IOM7220 | 7/32 inch | All Ports in Body | 24.0 VDC | Direct Acting | 10 W | 0.79 Cv | IP65 | n/a | 185 °F | 7R004 | 150 °F | 40 psig | 0 psi | 24 VDC | 2-Way | DIN 43650A / ISO 4400 | Lead-Free Brass | Normally Closed | NBR | 3/8 NPT | 7/32 | 0 | 40 | |
20LC06TN7D7F | Backordered | POR | 2-Way | Lead-Free Brass | NBR | CURus Safety Shutoff | Fluid Control Division | NPT 3/8 inch | IOM7220 | 7/32 inch | Normally Closed (NC) | 120/60 VAC | Direct Acting | 10 W | 0.79 Cv | IP65 | n/a | 185 °F | 7R004 | 150 °F | 110 psig | 0 psi | 120/60, 110/50 | 2-Way | DIN 43650A / ISO 4400 | Lead-Free Brass | Normally Closed | NBR | 3/8 NPT | 7/32 | 0 | 110 | |
22LC06TN7C7B | Backordered | POR | 2-Way | Lead-Free Brass | NBR | CULus Safety Shutoff | Fluid Control Division | NPT 3/8 inch | IOM7222 | 5/8 inch | All Ports in Body | 24.0 VDC | Internal Pilot | 10 W | 3 Cv | IP69 | n/a | 185 °F | 7R024 | 125 °F | 150 psig | 5 psi | 24 VDC | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | Lead-Free Brass | Normally Closed | NBR | 3/8 NPT | 5/8 | 5 | 150 | |
22LC06TN7C8B | Backordered | POR | 2-Way | Lead-Free Brass | NBR | CULus Safety Shutoff | Fluid Control Division | NPT 3/8 inch | IOM7222 | 5/8 inch | Normally Closed (NC) | 24.0 VDC | Internal Pilot | 22 W | 3 Cv | IP69 | n/a | 185 °F | 7R024 | 125 °F | 300 psig | 5 psi | 24 VDC | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | Lead-Free Brass | Normally Closed | NBR | 3/8 NPT | 5/8 | 5 | 300 | |
22LC06TN7D | Backordered | POR | 2-Way | Lead-Free Brass | NBR | - | Fluid Control Division | NPT 3/8 inch | IOM7222 | 5/8 inch | All Ports in Body | Pressure Vessel Only (DC Voltage) | Internal Pilot | 10 or 22 W | 3 Cv | Requires DC Voltage G7 Series Coil Kit | n/a | 185 °F | 7R024 | 125 °F | 150 psig (10 watt) | 5 psi | Pressure Vessel Only (DC Voltage) | 2-Way | Requires DC Voltage G7 Series Coil Kit | Lead-Free Brass | Normally Closed | NBR | 3/8 NPT | 5/8 | 5 | 300 (22 watt), 150 (10 watt) | |
22LC06TV7C7B | Backordered | POR | 2-Way | Lead-Free Brass | FKM | CULus Safety Shutoff | Fluid Control Division | NPT 3/8 inch | IOM7222 | 5/8 inch | All Ports in Body | 24.0 VDC | Internal Pilot | 10 W | 3 Cv | IP69 | n/a | 185 °F | 7R028 | 125 °F | 150 psig | 5 psi | 24 VDC | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | Lead-Free Brass | Normally Closed | FKM | 3/8 NPT | 5/8 | 5 | 150 | |
22LC08UN7B7A | Backordered | POR | 2-Way | Lead-Free Brass | NBR | CURus Safety Shutoff | Fluid Control Division | NPT 1/2 inch | IOM7222 | 5/8 inch | Normally Closed (NC) | 12.0 VDC | Internal Pilot | 10 W | 4 Cv | IP69 | n/a | 185 °F | 7R024 | 125 °F | 150 psig | 5 psi | 12 VDC | 2-Way | Leads-only (Incl. Ground Lead) | Lead-Free Brass | Normally Closed | NBR | 1/2 NPT | 5/8 | 5 | 150 | |
22LC08UN7C7B | Backordered | POR | 2-Way | Lead-Free Brass | NBR | CULus Safety Shutoff | Fluid Control Division | NPT 1/2 inch | IOM7222 | 5/8 inch | All Ports in Body | 24.0 VDC | Internal Pilot | 10 W | 4 Cv | IP69 | n/a | 185 °F | 7R024 | 125 °F | 150 psig | 5 psi | 24 VDC | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | Lead-Free Brass | Normally Closed | NBR | 1/2 NPT | 5/8 | 5 | 150 | |
22LC08UN7C8B | Backordered | POR | 2-Way | Lead-Free Brass | NBR | CULus Safety Shutoff | Fluid Control Division | NPT 1/2 inch | IOM7222 | 5/8 inch | All Ports in Body | 24.0 VDC | Internal Pilot | 22 W | 4 Cv | IP69 | n/a | 185 °F | 7R024 | 125 °F | 300 psig | 5 psi | 24 VDC | 2-Way | 1/2" NPT Conduit w/ Leads (Incl. Ground Lead) | Lead-Free Brass | Normally Closed | NBR | 1/2 NPT | 5/8 | 5 | 300 | |
22LC08UN7D | 1 in stock | POR | 2-Way | Lead-Free Brass | NBR | - | Fluid Control Division | NPT 1/2 inch | IOM7222 | 5/8 inch | All Ports in Body | Pressure Vessel Only (DC Voltage) | Internal Pilot | 10 or 22 W | 4 Cv | Requires DC Voltage G7 Series Coil Kit | n/a | 185 °F | 7R024 | 125 °F | 150 psig (10 watt) | 5 psi | Pressure Vessel Only (DC Voltage) | 2-Way | Requires DC Voltage G7 Series Coil Kit | Lead-Free Brass | Normally Closed | NBR | 1/2 NPT | 5/8 | 5 | 300 (22 watt), 150 (10 watt) | |
22LC08UN7D7A | Backordered | POR | 2-Way | Lead-Free Brass | NBR | CURus Safety Shutoff | Fluid Control Division | NPT 1/2 inch | IOM7222 | 5/8 inch | All Ports in Body | 12.0 VDC | Internal Pilot | 10 W | 4 Cv | NEMA 4 | n/a | 185 °F | 7R024 | 125 °F | 150 psig | 5 psi | 12 VDC | 2-Way | DIN 43650A / ISO 4400 | Lead-Free Brass | Normally Closed | NBR | 1/2 NPT | 5/8 | 5 | 150 |
REWARD Status
Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.
Click quantity In Stock to view warehouse location detail.