• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Body Material
  • Coil Specifications Met
  • Coil Type
  • Configuration
  • Configuration
  • Division
  • Exhaust Flow Coefficient
  • Function
More Filters...

G7 SERIES Solenoid Valves

Picture for category G7 SERIES Solenoid Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker Gold Ring™ and Skinner® valves have evolved.
The next generation of 2/2 and 3/2 solenoid valves delivers the confidence to get the job done in the most demanding applications.
High performance, Express Ship Program-eligibility, and a host of new and innovative features make doing business easier than ever before.
Ensuring high performance and an optimized total cost of ownership, Parker continues to focus on Engineering Your Success.

Features/ Benefits:
• Engineered for Long Life (up to 20 million cycles)
• Industry-Leading Pressure, Flow, and Temperature ratings - even in DC voltages
• IP69-rated Solenoid Coils
• Corrosion-Resistant Construction
• 24-Hour Express Ship Program
• Durable Laser-Marked Identification
• Innovative Parker Tracking System (PTS)

Markets:
• Commercial Equipment
• Food & Beverage
• Industrial Automation
• Oil & Gas
• Process Control
• Transportation

Applications
• Instrumentation Equipment
• Analyzers and Diagnostic Equipment
• Medical and Dental Equipment
• Portable Welding Equipment
• Spraying Equipment
• Lubrication Equipment
• Commercial and Industrial Plumbing
• Oil Burners
• Fuel Shut Off
• Textile and Dry Cleaning Equipment
• Irrigation Equipment
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceFunctionBody MaterialSeal MaterialSpecifications MetDivisionPort SizeInstallationOrifice SizeConfigurationInput VoltageActuation TypePower ConsumptionMain Flow CoefficientCoil Specifications MetExhaust Flow CoefficientMaximum Fluid TemperaturePreventive Maintenance KitMaximum Ambient TemperatureMaximum Pressure DifferentialMinimum Pressure DifferentialVoltageFunctionCoil TypeBody MaterialConfigurationSeal MaterialPort Size (inch)Orifice Size (inch)Minimum Pressure Differential (psi)Maximum Operating Pressure Differential (psig)
20LC04QN7C7E
Backordered
POR
2-WayLead-Free BrassNBRCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72205/32 inchAll Ports in Body24/60Direct Acting10 W0.43 CvIP69n/a185 °F7R004150 °F230 psig0 psi24/602-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedNBR1/4 NPT5/320230
20LC04QN7C7F
Backordered
POR
2-WayLead-Free BrassNBRCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72205/32 inchNormally Closed (NC)120/60 VACDirect Acting10 W0.43 CvIP69n/a185 °F7R004150 °F230 psig0 psi120/60, 110/502-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedNBR1/4 NPT5/320230
20LC04QN7D7B
Backordered
POR
2-WayLead-Free BrassNBRCURus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72205/32 inchAll Ports in Body24.0 VDCDirect Acting10 W0.43 CvIP65n/a185 °F7R004150 °F85 psig0 psi24 VDC2-WayDIN 43650A / ISO 4400Lead-Free BrassNormally ClosedNBR1/4 NPT5/32085
20LC04QN7D7E
Backordered
POR
2-WayLead-Free BrassNBRCURus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72205/32 inchAll Ports in Body24/60Direct Acting10 W0.43 CvNEMA 4n/a185 °F7R004150 °F230 psig0 psi24/602-WayDIN 43650A / ISO 4400Lead-Free BrassNormally ClosedNBR1/4 NPT5/320230
20LC04QV7
Backordered
POR
2-WayLead-Free BrassFKM-Fluid Control DivisionNPT 1/4 inchIOM72205/32 inchNormally Closed (NC)Pressure Vessel Only (AC or DC Voltage)Direct Acting10 W0.43 CvRequires G7 Series Coil Kitn/a185 °F7R003150 °F230 psig (AC)0 psiPressure Vessel Only (AC or DC Voltage)2-WayRequires G7 Series Coil KitLead-Free BrassNormally ClosedFKM1/4 NPT5/320230 (AC) / 85 (DC)
20LC04QV7C7B
Backordered
POR
2-WayLead-Free BrassFKMCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72205/32 inchAll Ports in Body24.0 VDCDirect Acting10 W0.43 CvIP69n/a185 °F7R003150 °F85 psig0 psi24 VDC2-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedFKM1/4 NPT5/32085
20LC04QV7C7E
Backordered
POR
2-WayLead-Free BrassFKMCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72205/32 inchAll Ports in Body24/60Direct Acting10 W0.43 CvIP69n/a185 °F7R003150 °F230 psig0 psi24/602-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedFKM1/4 NPT5/320230
20LC04QV7C7F
Backordered
POR
2-WayLead-Free BrassFKMCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72205/32 inchAll Ports in Body120/60 VACDirect Acting10 W0.43 CvIP69n/a185 °F7R003150 °F230 psig0 psi120/60, 110/502-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedFKM1/4 NPT5/320230
20LC04QV7D7B
1 in stock
POR
2-WayLead-Free BrassFKMCURus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72205/32 inchNormally Closed (NC)24.0 VDCDirect Acting10 W0.43 CvNEMA 4n/a185 °F7R003150 °F85 psig0 psi24 VDC2-WayDIN 43650A / ISO 4400Lead-Free BrassNormally ClosedFKM1/4 NPT5/32085
20LC04TN7
Backordered
POR
2-WayLead-Free BrassNBR-Fluid Control DivisionNPT 1/4 inchIOM72207/32 inchAll Ports in BodyPressure Vessel Only (AC or DC Voltage)Direct Acting10 W0.79 CvRequires G7 Series Coil Kitn/a185 °F7R004150 °F110.0 psig (AC)0 psiPressure Vessel Only (AC or DC Voltage)2-WayRequires G7 Series Coil KitLead-Free BrassNormally ClosedNBR1/4 NPT7/320110 (AC) / 40 (DC)
20LC04TN7C7B
Backordered
POR
2-WayLead-Free BrassNBRCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72207/32 inchNormally Closed (NC)24.0 VDCDirect Acting10 W0.79 CvIP69n/a185 °F7R004150 °F40 psig0 psi24 VDC2-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedNBR1/4 NPT7/32040
20LC04TN7C7F
Backordered
POR
2-WayLead-Free BrassNBRCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72207/32 inchNormally Closed (NC)120/60 VACDirect Acting10 W0.79 CvIP69n/a185 °F7R004150 °F110 psig0 psi120/60, 110/502-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedNBR1/4 NPT7/320110
20LC04TV7
Backordered
POR
2-WayLead-Free BrassFKM-Fluid Control DivisionNPT 1/4 inchIOM72207/32 inchAll Ports in BodyPressure Vessel Only (AC or DC Voltage)Direct Acting10 W0.79 CvRequires G7 Series Coil Kitn/a185 °F7R003150 °F110.0 psig (AC)0 psiPressure Vessel Only (AC or DC Voltage)2-WayRequires G7 Series Coil KitLead-Free BrassNormally ClosedFKM1/4 NPT7/320110 (AC) / 40 (DC)
20LC04TV7B7B
Backordered
POR
2-WayLead-Free BrassFKMCURus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72207/32 inchNormally Closed (NC)24.0 VDCDirect Acting10 W0.79 CvIP69n/a185 °F7R003150 °F40 psig0 psi24 VDC2-WayLeads-only (Incl. Ground Lead)Lead-Free BrassNormally ClosedFKM1/4 NPT7/32040
20LC04TV7C7B
Backordered
POR
2-WayLead-Free BrassFKMCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72207/32 inchNormally Closed (NC)24.0 VDCDirect Acting10 W0.79 CvIP69n/a185 °F7R003150 °F40 psig0 psi24 VDC2-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedFKM1/4 NPT7/32040
20LC04TV7C7F
Backordered
POR
2-WayLead-Free BrassFKMCULus Safety ShutoffFluid Control DivisionNPT 1/4 inchIOM72207/32 inchAll Ports in Body110/50 VACDirect Acting10 W0.79 CvIP69n/a185 °F7R003150 °F110 psig0 psi120/60, 110/502-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedFKM1/4 NPT7/320110
20LC061N7
Backordered
POR
2-WayLead-Free BrassNBR-Fluid Control DivisionNPT 3/8 inchIOM72209/32 inchAll Ports in BodyPressure Vessel Only (AC or DC Voltage)Direct Acting10 W1.06 CvRequires G7 Series Coil Kitn/a185 °F7R004150 °F40 psig (AC)0 psiPressure Vessel Only (AC or DC Voltage)2-WayRequires G7 Series Coil KitLead-Free BrassNormally ClosedNBR3/8 NPT9/32040 (AC) / 15 (DC)
20LC061N7C7B
Backordered
POR
2-WayLead-Free BrassNBRCULus Safety ShutoffFluid Control DivisionNPT 3/8 inchIOM72209/32 inchAll Ports in Body24.0 VDCDirect Acting10 W1.06 CvIP69n/a185 °F7R004150 °F15 psig0 psi24 VDC2-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedNBR3/8 NPT9/32015
20LC061N7C7F
Backordered
POR
2-WayLead-Free BrassNBRCULus Safety ShutoffFluid Control DivisionNPT 3/8 inchIOM72209/32 inchNormally Closed (NC)120/60 VACDirect Acting10 W1.06 CvIP69n/a185 °F7R004150 °F40 psig0 psi120/60, 110/502-Way1/2" NPT Conduit w/ Leads (Incl. Ground Lead)Lead-Free BrassNormally ClosedNBR3/8 NPT9/32040
20LC061N7D7F
Backordered
POR
2-WayLead-Free BrassNBRCURus Safety ShutoffFluid Control DivisionNPT 3/8 inchIOM72209/32 inchNormally Closed (NC)110/50 VACDirect Acting10 W1.06 CvNEMA 4Xn/a185 °F7R004150 °F40 psig0 psi120/60, 110/502-WayDIN 43650A / ISO 4400Lead-Free BrassNormally ClosedNBR3/8 NPT9/32040

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains