• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Adjustment Mechanism
  • Adjustment Type
  • Body Material
  • Cavity Size
  • Cracking Pressure
  • Cracking Pressure (psi)
  • Division
  • Division
  • Drain Option
More Filters...

Pilot Operated Sequence Valves

Picture for category Pilot Operated Sequence Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s selection of pilot operated sequence valves provide superior stability and are designed for sequenced applications with pressures up to 380 bar (5500 psi) and flows up to 152 lpm (40 gpm) in a variety of sizes. The variety of pressure adjustment styles and piloted or vented controls makes these valves an ideal solution for controlling multiple circuit sections that operate at different pressure settings. Normally-open and normally-closed valves are available in a 2 position 2-way configuration and can be either internally or externally drained depending on application needs. These pilot operated sequence valves can be used within clamping circuits or high/low system applications within several industrial and mobile markets.

Markets:
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• High pressure and flow capacity
• Internal screens for pilot spring protection
• Low profile designs
• Hardened, precision ground parts for durability
• All external parts zinc plated

Applications:
• Dump circuits
• High/low systems
• Sequencing applications

Additional Technical Insight:
SVH081, SVH101, and SVH161 pilot operated sequence valves are internally piloted and externally drained.  All three versions are normally closed spool-type valves that prevent flow from passing through the valve until the adjustable pressure setting is reached.  When the inlet pressure exceeds the sequence setting the valve is internally piloted open allowing flow downstream to a secondary function.  An external drain port plumbed directly to tank ensures that downstream pressure does not affect the pressure setting.  Clamp and machine, or unlock and dump, are typical applications since they require one function to happen before another one.

SVH102 and SVH162 are externally piloted and internally drained sequence valves.  Both are normally closed and prevent flow from passing through the valve when the pilot pressure is below the pressure setting.  When the external pilot source exceeds the adjustable pressure setting, the valve opens allowing flow to go downstream.  Back pressure on the downstream port is added to the valve setting due to the internal drain, therefore it is most common to connect the sequenced port to tank.  High-Low Pump Unloading is a common application.

SVCH101 is an inline mounted combination of an internally piloted, externally drained sequence valve and a reverse flow check.  An SVH101 sequence valve and a CVH103 check valve are incorporated into a single body with SAE-8 work ports and an SAE-6 drain.
Read More...
Sort by
Display per page
ActionSKUAvailabilityPriceBody MaterialMaximum Pressure SettingPort SizeSeal MaterialDivisionDivisionMinimum Operating TemperatureFlow RatePilot LocationMaximum Flow RateMaximum Kinematic ViscosityWeightMaximum Operating PressureActuation TypeAdjustment MechanismMaximum Tank PressureDrain OptionCavity SizeFunctionMounting TypeMaximum Inlet Pressure RatingFor Fluid TypeMaximum Operating TemperatureValve MaterialOperating TemperatureFilter Efficiency RatingInstallation TorqueStandard Setting PressureCracking PressurePressure Control RangeLeak RateReseat PressurePressure Control SensitivityMaximum Drain Flow RateDrain OptionSeal MaterialAdjustment TypeCracking Pressure (psi)Pressure Range Adjustment (psi)Pilot OptionRated Flow (gpm)
SVH102S30V
Backordered
$108.00
N/A210 barn/aFluorocarbonHydraulic Systems DivisionHydraulic Cartridge Systems Division-15 °F15 Gal/minExternal15 Gal/min45-2000 SSU (6 to 420 cSt)1 lb380 barPressure SensingScrew5000 psiInternalC10-3Pilot Operated SequenceThreaded Cartridge Valve380 barMineral-based or synthetic hydraulic fluids+204 °CAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 469-75 Nm1500 psiN/A psi200-3000 psi82 @ 3000 PSI (210 BAR) cm3/min90% of set pressure59 per turn bar0.4 L/minInternalFluorocarbonScrewN/A200-3000External15
SVH102S50
Backordered
$101.10
N/A350 barn/aD-Ring (Standard)Hydraulic Systems DivisionHydraulic Cartridge Systems Division-35 °F15 Gal/minExternal15 Gal/min45-2000 SSU (6 to 420 cSt)1 lb380 barPressure SensingScrew350 barInternalC10-3Pilot Operated SequenceThreaded Cartridge Valve5500 psiMineral-based or synthetic hydraulic fluids+200 °FAll parts steel. All operating parts hardened steel-37 to +93 °CISO 4406 18/16/13, SAE Class 451-55 lb-ft172.4 barN/A bar13.8-350 bar82 @ 3000 PSI (210 BAR) cm3/min90% of set pressure1910 per turn psi0.5 L/minInternalD-Ring (Standard)ScrewN/A200-5000External15
SVH102S50N
Backordered
$108.00
N/A350 barn/aNitrileHydraulic Systems DivisionHydraulic Cartridge Systems Division-30 °F15 Gal/minExternal15 Gal/min45-2000 SSU (6 to 420 cSt)1 lb380 barPressure SensingScrew5000 psiInternalC10-3Pilot Operated SequenceThreaded Cartridge Valve380 barMineral-based or synthetic hydraulic fluids+121 °CAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 469-75 Nm2500 psiN/A psi200-5000 psi82 @ 3000 PSI (210 BAR) cm3/min90% of set pressure131.7 per turn bar0.5 L/minInternalNitrileScrewN/A200-5000External15
SVH102S50V
Backordered
$108.00
N/A350 barn/aFluorocarbonHydraulic Systems DivisionHydraulic Cartridge Systems Division-26 °C15 Gal/minExternal56.3 L/min45-2000 SSU (6 to 420 cSt)0.45 kg5500 psiPressure SensingScrew350 barInternalC10-3Pilot Operated SequenceThreaded Cartridge Valve380 barMineral-based or synthetic hydraulic fluids+400 °FAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 469-75 Nm2500 psiN/A psi13.8-350 bar82 @ 3000 PSI (210 BAR) cm3/min90% of set pressure131.7 per turn bar1.87 Gal/minInternalFluorocarbonScrewN/A200-5000External15
SVH102T10
Backordered
POR
N/A69 barn/aD-Ring (Standard)Hydraulic Systems DivisionHydraulic Cartridge Systems Division-35 °F15 Gal/minExternal56.3 L/min45-2000 SSU (6 to 420 cSt)1 lb380 barPressure SensingTamper Resistant350 barInternalC10-3Pilot Operated SequenceThreaded Cartridge Valve380 barMineral-based or synthetic hydraulic fluids+93 °CAll parts steel. All operating parts hardened steel-37 to +93 °CISO 4406 18/16/13, SAE Class 469-75 Nm500 psiN/A psi100-1000 psi82 @ 3000 PSI (210 BAR) cm3/min90% of set pressure19.6 per turn bar0.2 L/minInternalD-Ring (Standard)Tamper ResistantN/A300-1000External15
SVH102T30
Backordered
POR
N/A210 barn/aD-Ring (Standard)Hydraulic Systems DivisionHydraulic Cartridge Systems Division-37 °C15 Gal/minExternal15 Gal/min45-2000 SSU (6 to 420 cSt)0.45 kg5500 psiPressure SensingTamper Resistant5000 psiInternalC10-3Pilot Operated SequenceThreaded Cartridge Valve5500 psiMineral-based or synthetic hydraulic fluids+200 °FAll parts steel. All operating parts hardened steel-35 to +200 °FISO 4406 18/16/13, SAE Class 451-55 lb-ft103.5 barN/A bar13.8-210 bar82 @ 3000 PSI (210 BAR) cm3/min90% of set pressure859 per turn psi0.4 L/minInternalD-Ring (Standard)Tamper ResistantN/A200-3000External15
SVH102T30N
Backordered
POR
N/A3000 psin/aNitrileHydraulic Systems DivisionHydraulic Cartridge Systems Division-30 °F56.3 L/minExternal15 Gal/min45-2000 SSU (6 to 420 cSt)0.45 kg380 barPressure SensingTamper Resistant350 barInternalC10-3Pilot Operated SequenceThreaded Cartridge Valve5500 psiMineral-based or synthetic hydraulic fluids+121 °CAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 451-55 lb-ft103.5 barN/A bar13.8-210 bar82 @ 3000 PSI (210 BAR) cm3/min90% of set pressure859 per turn psi0.4 L/minInternalNitrileTamper ResistantN/A200-3000External15
SVH102T30V
Backordered
POR
N/A210 barn/aFluorocarbonHydraulic Systems DivisionHydraulic Cartridge Systems Division-26 °C56.3 L/minExternal56.3 L/min45-2000 SSU (6 to 420 cSt)0.45 kg5500 psiPressure SensingTamper Resistant5000 psiInternalC10-3Pilot Operated SequenceThreaded Cartridge Valve5500 psiMineral-based or synthetic hydraulic fluids+400 °FAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 451-55 lb-ft103.5 barN/A bar13.8-210 bar82 @ 3000 PSI (210 BAR) cm3/min90% of set pressure859 per turn psi1.53 Gal/minInternalFluorocarbonTamper ResistantN/A200-3000External15
SVH102T50
Backordered
POR
N/A5000 psin/aD-Ring (Standard)Hydraulic Systems DivisionHydraulic Cartridge Systems Division-35 °F56.3 L/minExternal15 Gal/min45-2000 SSU (6 to 420 cSt)0.45 kg380 barPressure SensingTamper Resistant350 barInternalC10-3Pilot Operated SequenceThreaded Cartridge Valve380 barMineral-based or synthetic hydraulic fluids+93 °CAll parts steel. All operating parts hardened steel-37 to +93 °CISO 4406 18/16/13, SAE Class 451-55 lb-ft172.4 barN/A psi13.8-350 bar82 @ 3000 PSI (210 BAR) cm3/min90% of set pressure1910 per turn psi0.5 L/minInternalD-Ring (Standard)Tamper ResistantN/A200-5000External15
SVH102T50V
Backordered
POR
N/A350 barn/aFluorocarbonHydraulic Systems DivisionHydraulic Cartridge Systems Division-15 °F56.3 L/minExternal15 Gal/min45-2000 SSU (6 to 420 cSt)1 lb380 barPressure SensingTamper Resistant5000 psiInternalC10-3Pilot Operated SequenceThreaded Cartridge Valve380 barMineral-based or synthetic hydraulic fluids+204 °CAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 451-55 lb-ft172.4 barN/A psi13.8-350 bar82 @ 3000 PSI (210 BAR) cm3/min90% of set pressure1910 per turn psi0.5 L/minInternalFluorocarbonTamper ResistantN/A200-5000External15
SVH161K20
Backordered
POR
N/A138 barn/aNitrileHydraulic Systems DivisionHydraulic Cartridge Systems Division-30 °F40 Gal/minInternal40 Gal/min45-2000 SSU (6 to 420 cSt)0.45 kg380 barPressure SensingKnob350 barExternal6-3Pilot Operated SequenceThreaded Cartridge Valve5500 psiMineral-based or synthetic hydraulic fluids+250 °FAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 473 lb-ft1000 psiN/A bar200-2000 psi5 per 100 psi (6.8 bar) setting cm3/min80% of set pressure539 per turn psi0.5 L/minExternalNitrileKnobN/A200-2000Internal40
SVH161K30
Backordered
POR
N/A210 barn/aNitrileHydraulic Systems DivisionHydraulic Cartridge Systems Division-30 °F40 Gal/minInternal40 Gal/min45-2000 SSU (6 to 420 cSt)0.45 kg380 barPressure SensingKnob5000 psiExternal6-3Pilot Operated SequenceThreaded Cartridge Valve5500 psiMineral-based or synthetic hydraulic fluids+250 °FAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 473 lb-ft1500 psiN/A bar300-3000 psi5 per 100 psi (6.8 bar) setting cm3/min80% of set pressure59.7 per turn bar0.5 L/minExternalNitrileKnobN/A300-3000Internal40
SVH161K50
Backordered
POR
N/A5000 psin/aNitrileHydraulic Systems DivisionHydraulic Cartridge Systems Division-34 °C40 Gal/minInternal40 Gal/min45-2000 SSU (6 to 420 cSt)1 lb5500 psiPressure SensingKnob5000 psiExternal6-3Pilot Operated SequenceThreaded Cartridge Valve5500 psiMineral-based or synthetic hydraulic fluids+121 °CAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 473 lb-ft2500 psiN/A psi500-5000 psi5 per 100 psi (6.8 bar) setting cm3/min80% of set pressure118 per turn bar0.5 L/minExternalNitrileKnobN/A500-5000Internal40
SVH161S10
1 in stock
POR
N/A69 barn/aNitrileHydraulic Systems DivisionHydraulic Cartridge Systems Division-34 °C40 Gal/minInternal151.6 L/min45-2000 SSU (6 to 420 cSt)1 lb5500 psiPressure SensingScrew5000 psiExternal6-3Pilot Operated SequenceThreaded Cartridge Valve380 barMineral-based or synthetic hydraulic fluids+250 °FAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 499 Nm34.5 barN/A bar6.9-69 bar5 per 100 psi (6.8 bar) setting cm3/min80% of set pressure23 per turn bar0.5 L/minExternalNitrileScrewN/A100-1000Internal40
SVH161S10V
Backordered
POR
N/A1000 psin/aFluorocarbonHydraulic Systems DivisionHydraulic Cartridge Systems Division-15 °F151.6 L/minInternal151.6 L/min45-2000 SSU (6 to 420 cSt)0.45 kg380 barPressure SensingScrew350 barExternal6-3Pilot Operated SequenceThreaded Cartridge Valve380 barMineral-based or synthetic hydraulic fluids+400 °FAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 499 Nm34.5 barN/A psi6.9-69 bar5 per 100 psi (6.8 bar) setting cm3/min80% of set pressure23 per turn bar1.87 Gal/minExternalFluorocarbonScrewN/A100-1000Internal40
SVH161S20
Backordered
POR
N/A2000 psin/aNitrileHydraulic Systems DivisionHydraulic Cartridge Systems Division-34 °C40 Gal/minInternal151.6 L/min45-2000 SSU (6 to 420 cSt)1 lb5500 psiPressure SensingScrew5000 psiExternal6-3Pilot Operated SequenceThreaded Cartridge Valve5500 psiMineral-based or synthetic hydraulic fluids+121 °CAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 473 lb-ft69 barN/A bar200-2000 psi5 per 100 psi (6.8 bar) setting cm3/min80% of set pressure37 per turn bar0.5 L/minExternalNitrileScrewN/A200-2000Internal40
SVH161S30
Backordered
POR
N/A3000 psin/aNitrileHydraulic Systems DivisionHydraulic Cartridge Systems Division-30 °F40 Gal/minInternal40 Gal/min45-2000 SSU (6 to 420 cSt)0.45 kg380 barPressure SensingScrew5000 psiExternal6-3Pilot Operated SequenceThreaded Cartridge Valve5500 psiMineral-based or synthetic hydraulic fluids+250 °FAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 473 lb-ft103.5 barN/A bar300-3000 psi5 per 100 psi (6.8 bar) setting cm3/min80% of set pressure867 per turn psi0.5 L/minExternalNitrileScrewN/A300-3000Internal40
SVH161S30V
Backordered
POR
N/A210 barn/aFluorocarbonHydraulic Systems DivisionHydraulic Cartridge Systems Division-15 °F40 Gal/minInternal151.6 L/min45-2000 SSU (6 to 420 cSt)1 lb380 barPressure SensingScrew5000 psiExternal6-3Pilot Operated SequenceThreaded Cartridge Valve5500 psiMineral-based or synthetic hydraulic fluids+204 °CAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 499 Nm103.5 barN/A psi20.7-210 bar5 per 100 psi (6.8 bar) setting cm3/min80% of set pressure867 per turn psi0.5 L/minExternalFluorocarbonScrewN/A300-3000Internal40
SVH161S50
Backordered
POR
N/A350 barn/aNitrileHydraulic Systems DivisionHydraulic Cartridge Systems Division-30 °F151.6 L/minInternal40 Gal/min45-2000 SSU (6 to 420 cSt)0.45 kg380 barPressure SensingScrew350 barExternal6-3Pilot Operated SequenceThreaded Cartridge Valve5500 psiMineral-based or synthetic hydraulic fluids+250 °FAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 473 lb-ft172.4 barN/A bar500-5000 psi5 per 100 psi (6.8 bar) setting cm3/min80% of set pressure1711 per turn psi1.87 Gal/minExternalNitrileScrewN/A500-5000Internal40
SVH161S50V
Backordered
POR
N/A350 barn/aFluorocarbonHydraulic Systems DivisionHydraulic Cartridge Systems Division-15 °F151.6 L/minInternal151.6 L/min45-2000 SSU (6 to 420 cSt)0.45 kg380 barPressure SensingScrew350 barExternal6-3Pilot Operated SequenceThreaded Cartridge Valve5500 psiMineral-based or synthetic hydraulic fluids+400 °FAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 499 Nm172.4 barN/A psi34.5-350 bar5 per 100 psi (6.8 bar) setting cm3/min80% of set pressure1711 per turn psi0.5 L/minExternalFluorocarbonScrewN/A500-5000Internal40

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains