Action | SKU | Availability | Price | Body Material | Maximum Operating Pressure | Seal Material | Division | Division | Minimum Operating Temperature | Maximum Kinematic Viscosity | Override Functionality | Maximum Flow Rate | Flow Rate | Coil Type | Actuation Type | Operation Type | Power Consumption | Installation Torque | Coil Nut Tightening Torque | Response Time | For Fluid Type | Maximum Operating Temperature | Frequency | Valve Material | Operating Temperature | Filter Efficiency Rating | Maximum Inlet Pressure Rating | Mounting Type | Wire Mesh Screen Included | Weight | Maximum Tank Pressure | Function | Maximum Pressure Setting | Cavity Size | Leak Rate | Current | Hysteresis | Configuration | Flow Direction | Maximum Drain Flow Rate | Maximum Regulating Pressure | Override Functionality | Seal Material | Maximum Inlet Pressure Rating | Maximum Flow Rate | Wire Mesh Screen Included | Configuration | Maximum Regulating Pressure |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GTP04340501V | Backordered | POR | N/A | 3000 psi | Fluorocarbon | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | -26 °C | 45-2000 SSU (6 to 420 cSt) | n/a | 30 L/min | 30 L/min | 5/8" Super Coil High Watt (CAP) | Electrical | Solenoid Operated | 28 W | 30 Nm | 3 lb-ft | 40 ms | Mineral-based or synthetic hydraulic fluids | +204 °C | 100-400 Hz | All parts steel. All operating parts hardened steel | -26 to +204 °C | ISO 4406 18/16/13, SAE Class 4 | 210 bar | Screw in cartridge valve | Yes | 0.28 lb | N/A psi | Proportional Pressure Reducing | N/A psi | 3X | N/A cm3/min | 1.4 at 12VDC (High watt), 0.7 at 24VDC (High watt) A | 3.5% | Side Cylinder Port | Inlet port 3, Reducing port 2, Tank port 1 | 25 De-Energized, 800 In Regulating Zone @ 300 PSI (21 BAR) cm3/min | 29-38 bar | N/A | Fluorocarbon | 3000 PSI, 210 BAR | 8 GAL/MIN, 30 L/MIN | Yes | Side Cylinder Port | 420-550 PSI, 29-38 BAR | |
GTP04340551V | Backordered | POR | N/A | 210 bar | Fluorocarbon | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | -26 °C | 45-2000 SSU (6 to 420 cSt) | Infinite Control | 30 L/min | 30 L/min | 5/8" Super Coil High Watt (CAP) | Electrical, Manual | Solenoid operated, Manually operated | 28 W | 30 Nm | 3 lb-ft | 40 ms | Mineral-based or synthetic hydraulic fluids | +400 °F | 100-400 Hz | All parts steel. All operating parts hardened steel | -15 to +400 °F | ISO 4406 18/16/13, SAE Class 4 | 210 bar | Screw in cartridge valve | Yes | 0.13 kg | N/A psi | Proportional Pressure Reducing | N/A psi | 3X | N/A cm3/min | 1.4 at 12VDC (High watt), 0.7 at 24VDC (High watt) A | 3.5% | Side Cylinder Port | Inlet port 3, Reducing port 2, Tank port 1 | 25 De-Energized, 800 In Regulating Zone @ 300 PSI (21 BAR) cm3/min | 420-550 psi | Infinite Control | Fluorocarbon | 3000 PSI, 210 BAR | 8 GAL/MIN, 30 L/MIN | Yes | Side Cylinder Port | 420-550 PSI, 29-38 BAR | |
GTP04340901N | Backordered | POR | N/A | 210 bar | Nitrile | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | -30 °F | 45-2000 SSU (6 to 420 cSt) | n/a | 30 L/min | 8 Gal/min | 5/8" Super Coil High Watt (CAP) | Electrical | Solenoid Operated | 28 W | 30 Nm | 3 lb-ft | 40 ms | Mineral-based or synthetic hydraulic fluids | +250 °F | 100-400 Hz | All parts steel. All operating parts hardened steel | -34 to +121 °C | ISO 4406 18/16/13, SAE Class 4 | 3000 psi | Screw in cartridge valve | Yes | 0.13 kg | N/A psi | Proportional Pressure Reducing | N/A psi | 3X | N/A cm3/min | 1.4 at 12VDC (High watt), 0.7 at 24VDC (High watt) A | 3.5% | Side Cylinder Port | Inlet port 3, Reducing port 2, Tank port 1 | 25 De-Energized, 800 In Regulating Zone @ 300 PSI (21 BAR) cm3/min | 56-74 bar | N/A | Nitrile | 3000 PSI, 210 BAR | 8 GAL/MIN, 30 L/MIN | Yes | Side Cylinder Port | 810-1080 PSI, 56-74 BAR | |
GTP04340901V | Backordered | POR | N/A | 3000 psi | Fluorocarbon | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | -15 °F | 45-2000 SSU (6 to 420 cSt) | n/a | 30 L/min | 30 L/min | 5/8" Super Coil High Watt (CAP) | Electrical | Solenoid Operated | 28 W | 22 lb-ft | 4.1 Nm | 40 ms | Mineral-based or synthetic hydraulic fluids | +204 °C | 100-400 Hz | All parts steel. All operating parts hardened steel | -26 to +204 °C | ISO 4406 18/16/13, SAE Class 4 | 3000 psi | Screw in cartridge valve | Yes | 0.28 lb | N/A psi | Proportional Pressure Reducing | N/A psi | 3X | N/A cm3/min | 1.4 at 12VDC (High watt), 0.7 at 24VDC (High watt) A | 3.5% | Side Cylinder Port | Inlet port 3, Reducing port 2, Tank port 1 | 25 De-Energized, 800 In Regulating Zone @ 300 PSI (21 BAR) cm3/min | 56-74 bar | N/A | Fluorocarbon | 3000 PSI, 210 BAR | 8 GAL/MIN, 30 L/MIN | Yes | Side Cylinder Port | 810-1080 PSI, 56-74 BAR |
REWARD Status
Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.
Click quantity In Stock to view warehouse location detail.